104745-8800 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047458800


104745-8800 INJECTION-PUMP ASSEMBLY
Rating:
23
Buy INJECTION-PUMP ASSEMBLY 104745-8800 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104745-8800 1047458800

Cross reference number

ZEXEL 104745-8800 1047458800


Zexel num
Bosch num
Firm num
Name
104745-8800 
 
   
INJECTION-PUMP ASSEMBLY
11CJ VE4 VE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   55.4 54.9 55.9
Difference in delivery mm3/st.   4.5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   47.7 45.2 50.2
Oil temperature degC   48 46 50
Injection timing adjustment_03
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   55.4 54.4 56.4
Difference in delivery mm3/st.   5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   53.4 50.9 55.9
Oil temperature degC   50 48 52
Injection timing adjustment_05
Pump speed r/min   2000 2000 2000
Average injection quantity mm3/st.   57 53.5 60.5
Oil temperature degC   50 48 52
Injection quantity adjustment
Pump speed r/min   2475 2475 2475
Average injection quantity mm3/st.   18.5 15.5 21.5
Difference in delivery mm3/st.   5.5
Basic   *
Oil temperature degC   52 50 54
Injection quantity adjustment_02
Pump speed r/min   2800 2800 2800
Average injection quantity mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2475 2475 2475
Average injection quantity mm3/st.   18.5 13.5 23.5
Difference in delivery mm3/st.   6
Basic   *
Oil temperature degC   52 50 54
Governor adjustment
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   13.4 11.4 15.4
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   13.4 10.9 15.9
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_03
Pump speed r/min   750 750 750
Average injection quantity mm3/st.   5
Oil temperature degC   50 48 52
Timer adjustment
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   46 36 56
Basic   *
Oil temperature degC   48 46 50
Remarks
IDLE
 
Timer adjustment_02
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   46 36 56
Oil temperature degC   48 46 50
Remarks
IDLE
 
Speed control lever angle
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1250 1250 1250
Overflow quantity cm3/min   800 670 930
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   1250 1250 1250
Pressure kPa   579 559 599
Pressure kgf/cm2   5.9 5.7 6.1
Basic   *
Oil temperature degC   50 48 52
0000001101
Pump speed r/min   1250 1250 1250
Timer stroke mm   4.9 4.7 5.1
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   700 700 700
Timer stroke mm   2.4 1.8 3
Oil temperature degC   50 48 52
_03
Pump speed r/min   1250 1250 1250
Timer stroke mm   4.9 4.5 5.3
Basic   *
Oil temperature degC   50 48 52
_04
Pump speed r/min   2000 2000 2000
Timer stroke mm   7.4 6.9 7.8
Oil temperature degC   50 48 52
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001501
Pump speed r/min   1000 1000 1000
Height m   2000 2000 2000
Atmospheric pressure difference kPa   -21.9 -21.9 -21.9
Atmospheric pressure difference mmHg   -164 -164 -164
Average injection quantity mm3/st.   48.8 47.3 50.3
Decrease qty mm3/st.   6.6 6.6 6.6
Decrease rate %   12 12 12
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   1000 1000 1000
Height m   0 0 0
Atmospheric pressure difference kPa   0 0 0
Atmospheric pressure difference mmHg   0 0 0
Average injection quantity mm3/st.   55.4 54.4 56.4
Oil temperature degC   50 48 52
_03
Pump speed r/min   1000 1000 1000
Height m   500 500 500
Atmospheric pressure difference kPa   -5.9 -9.2 -2.6
Atmospheric pressure difference mmHg   44 19 69
Average injection quantity mm3/st.   55.4 55.4 55.4
Oil temperature degC   50 48 52
_04
Pump speed r/min   1000 1000 1000
Height m   2000 2000 2000
Atmospheric pressure difference kPa   -21.9 -21.9 -21.9
Atmospheric pressure difference mmHg   -164 -164 -164
Average injection quantity mm3/st.   48.8 46.8 50.8
Basic   *
Oil temperature degC   50 48 52
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   1.1 1 1.2
Control lever angle alpha deg.   59 55 63
Control lever angle beta deg.   42 37 47

Test data Ex:

0000001801 V-FICD ADJUSTMENT

Test data 104745-8800
Standards for adjusting the double stage actuator (A) Control lever (B): Idle set bracket (C): Actuator stroke = L1 (D): Negative pressure inlet (E): Stroke adjusting screw (F): Stroke adjusting nut (G): Rod position adjusting nut L:Thickness of the shim Actuator adjustment (1)Mount the actuator to the injection pump. (2)Position the control lever in the idling position. (3)Adjust with the nut (G) so that the space between the control lever and the rod is L2. (4)Insert a shim with thickness of L between the lever (A) and the bracket (B). (5)At that time, adjust with the screw (E) and fix with the nut (F) so that the actuator stroke (C) is the full stroke [with P applied to the negative pressure inlet port (D)]. (6)Allowable angle when adjusting the rod position: c
----------
L1=12.5(mm) L2=1+1(mm) L3=12.1+-0.05(mm) P=-66.7kPa(-500mmHg) c=+-20(deg)
----------
a=20(deg) b=20(deg) L=12.1+-0.05mm L1=12.5mm L2=1+1mm T1=1.4~2.0N-m(0.14~0.2kgf-m) T2=3.4~4.9N-m(0.35~0.5kgf-m) SW1=SW7 SW2=SW8




Have questions with 104745-8800?





Group cross 104745-8800 ZEXEL

104745-8800  
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 460 614 551 
ME202935 
INJECTION-PUMP ASSEMBLY
4M40 NA
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 460 613 248 
MD362557 
INJECTION-PUMP ASSEMBLY
4D56
9 460 613 249 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 460 613 875 
MD361634 
INJECTION-PUMP ASSEMBLY
4D56
9 460 614 552 
MD361639 
INJECTION-PUMP ASSEMBLY
4D56
9 460 613 305 
MD363340 
INJECTION-PUMP ASSEMBLY
4D56
9 460 613 305 
ME994983 
INJECTION-PUMP ASSEMBLY
4D56
9 460 613 306 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 460 613 306 
MD363341 
INJECTION-PUMP ASSEMBLY
F 01G 09W 0FC 
MD363341 
INJECTION-PUMP ASSEMBLY
4D56
F 01G 09W 0FC 
ME994984 
INJECTION-PUMP ASSEMBLY
4D56
9 460 611 621 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 460 613 844 
MD358170 
INJECTION-PUMP ASSEMBLY
4D56
9 460 611 622 
MD358171 
INJECTION-PUMP ASSEMBLY
4D56
9 460 613 448 
MD364504 
INJECTION-PUMP ASSEMBLY
4D56
9 460 613 374 
MD368057 
INJECTION-PUMP ASSEMBLY
4D56
9 460 613 374 
ME994985 
INJECTION-PUMP ASSEMBLY
4D56
Back to top