Rating:
Information injection-pump assembly
ZEXEL
104741-6820
1047416820
ISUZU
8970126510
8970126510
Cross reference number
ZEXEL
104741-6820
1047416820
ISUZU
8970126510
8970126510
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105780-0060
Bosch type code
NP-DN0SD1510
Nozzle holder
105780-2150
Opening pressure
MPa
13
13
13.3
Opening pressure
kgf/cm2
133
133
136
Injection pipe
157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-450
Inside diameter - outside diameter - length (mm) mm 2-6-450
Joint assembly
157641-4720
Tube assembly
157641-4020
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
40
39.5
40.5
Difference in delivery
mm3/st.
3.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_02
Pump speed
r/min
400
400
400
Average injection quantity
mm3/st.
39.7
39.7
39.7
Oil temperature
degC
48
46
50
Injection timing adjustment_03
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
38.1
38.1
38.1
Oil temperature
degC
48
46
50
Injection timing adjustment_04
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
40
39
41
Difference in delivery
mm3/st.
3.5
Basic
*
Oil temperature
degC
50
48
52
Injection timing adjustment_05
Pump speed
r/min
1175
1175
1175
Average injection quantity
mm3/st.
42.9
42.9
42.9
Oil temperature
degC
50
48
52
Injection quantity adjustment
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
20
17
23
Difference in delivery
mm3/st.
4
Basic
*
Oil temperature
degC
50
48
52
Injection quantity adjustment_02
Pump speed
r/min
1350
1350
1350
Average injection quantity
mm3/st.
3
Oil temperature
degC
50
48
52
Injection quantity adjustment_03
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
20
17
23
Difference in delivery
mm3/st.
4
Oil temperature
degC
50
48
52
Governor adjustment
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
19.9
17.9
21.9
Difference in delivery
mm3/st.
2
Basic
*
Oil temperature
degC
48
46
50
Governor adjustment_02
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
19.9
17.9
21.9
Difference in delivery
mm3/st.
2
Oil temperature
degC
48
46
50
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
50
47
53
Basic
*
Oil temperature
degC
48
46
50
Remarks
Full
Full
Timer adjustment_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
50
47
53
Oil temperature
degC
48
46
50
Speed control lever angle
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
0
0
0
Oil temperature
degC
48
46
50
Remarks
Magnet OFF at idling position
Magnet OFF at idling position
0000000901
Pump speed
r/min
800
800
800
Overflow quantity
cm3/min
290
160
420
Oil temperature
degC
50
48
52
Stop lever angle
Pump speed
r/min
800
800
800
Pressure
kPa
235
215
255
Pressure
kgf/cm2
2.4
2.2
2.6
Basic
*
Oil temperature
degC
50
48
52
Stop lever angle_02
Pump speed
r/min
800
800
800
Pressure
kPa
235
215
255
Pressure
kgf/cm2
2.4
2.2
2.6
Basic
*
Oil temperature
degC
50
48
52
0000001101
Pump speed
r/min
800
800
800
Timer stroke
mm
1.1
0.9
1.3
Basic
*
Oil temperature
degC
50
48
52
_02
Pump speed
r/min
650
650
650
Timer stroke
mm
0.5
0.1
1.3
Oil temperature
degC
50
48
52
_03
Pump speed
r/min
800
800
800
Timer stroke
mm
1.1
0.9
1.3
Basic
*
Oil temperature
degC
50
48
52
_04
Pump speed
r/min
1175
1175
1175
Timer stroke
mm
2.4
2.1
2.8
Oil temperature
degC
50
48
52
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
2.8
2.7
2.9
KF dimension
mm
5
4.9
5.1
MS dimension
mm
1.8
1.7
1.9
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
25
21
29
Control lever angle beta
deg.
23
18
28
Test data Ex:
0000001801 STARTING I/Q ADJUSTMENT
Starting injection quantity adjustment
Adjust the adjusting bolt A so that the starting injection quantity adjustment is within the standards. Fix using the nut B.
(C) Stop lever
L:Adjustment dimensions
----------
L=2~8.5mm
----------
L=2~8.5mm
----------
L=2~8.5mm
----------
L=2~8.5mm