Rating:
Information injection-pump assembly
BOSCH
9 460 612 228
9460612228
ZEXEL
104741-6210
1047416210
Components :
0. | INJECTION-PUMP ASSEMBLY | 104741-6210 |
1. | _ | |
2. | FUEL INJECTION PUMP | 104641-6210 |
3. | NUMBER PLATE | |
4. | _ | |
5. | CAPSULE | |
6. | ADJUSTING DEVICE | |
7. | NOZZLE AND HOLDER ASSY | 105118-4224 |
8. | Nozzle and Holder | |
9. | Open Pre:MPa(Kqf/cm2) | 18.1(185) |
10. | NOZZLE-HOLDER | 105048-3230 |
11. | NOZZLE | 105017-1550 |
Include in #2:
104741-6210
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
9 460 612 228
9460612228
ZEXEL
104741-6210
1047416210
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
48.1
47.6
48.6
Difference in delivery
mm3/st.
3.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
1350
1350
1350
Average injection quantity
mm3/st.
18.3
14.8
21.8
Injection timing adjustment_03
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
47.2
44.2
50.2
Injection timing adjustment_04
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
48.1
47.1
49.1
Injection timing adjustment_05
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
52.5
48.5
56.5
Injection quantity adjustment
Pump speed
r/min
1350
1350
1350
Average injection quantity
mm3/st.
18.3
15.3
21.3
Difference in delivery
mm3/st.
4.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
1450
1450
1450
Average injection quantity
mm3/st.
5
Governor adjustment
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
9.6
7.6
11.6
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
9.6
7.6
11.6
Governor adjustment_03
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
95
75
115
Basic
*
Speed control lever angle
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
0
0
0
0000000901
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
279
150
408
Stop lever angle
Pump speed
r/min
1000
1000
1000
Pressure
kPa
225.5
206
245
Pressure
kgf/cm2
2.3
2.1
2.5
Basic
*
Stop lever angle_02
Pump speed
r/min
1000
1000
1000
Pressure
kPa
225.5
206
245
Pressure
kgf/cm2
2.3
2.1
2.5
Stop lever angle_03
Pump speed
r/min
1400
1400
1400
Pressure
kPa
284.5
255
314
Pressure
kgf/cm2
2.9
2.6
3.2
0000001101
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
0.7
0.5
0.9
Basic
*
_02
Pump speed
r/min
700
700
700
Timer stroke
mm
0.5
_03
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
0.7
0.4
1
_04
Pump speed
r/min
1400
1400
1400
Timer stroke
mm
1.55
1.2
1.9
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
2.8
2.7
2.9
KF dimension
mm
5
4.9
5.1
MS dimension
mm
1
0.9
1.1
Control lever angle alpha
deg.
18
14
22
Control lever angle beta
deg.
37
32
42