104741-6080 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047416080 8943272630


104741-6080 INJECTION-PUMP ASSEMBLY
Rating:
58
Buy INJECTION-PUMP ASSEMBLY 104741-6080 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104741-6080 1047416080
ISUZU 8943272630 8943272630

Cross reference number

ZEXEL 104741-6080 1047416080
ISUZU 8943272630 8943272630


Zexel num
Bosch num
Firm num
Name
104741-6080 
104741-6430 
 
8943272630  ISUZU
INJECTION-PUMP ASSEMBLY
4JB1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Left
  L
(Solenoid timer adjustment condition)   OFF
Injection timing adjustment
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   39.4 38.9 39.9
Difference in delivery mm3/st.   3.5
Basic   *
Injection timing adjustment_02
Pump speed r/min   2100 2100 2100
Average injection quantity mm3/st.   13 9.5 16.5
Injection timing adjustment_03
Pump speed r/min   1800 1800 1800
Average injection quantity mm3/st.   45.3 42.3 48.3
Injection timing adjustment_04
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   42.8 40.3 45.3
Injection timing adjustment_05
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   39.4 38.4 40.4
Injection timing adjustment_06
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   32.4 29.9 34.9
Injection timing adjustment_07
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   33 27.5 38.5
Injection quantity adjustment
Pump speed r/min   2100 2100 2100
Average injection quantity mm3/st.   13 10 16
Difference in delivery mm3/st.   4
Basic   *
Injection quantity adjustment_02
Pump speed r/min   2300 2300 2300
Average injection quantity mm3/st.   5
Governor adjustment
Pump speed r/min   390 390 390
Average injection quantity mm3/st.   6.7 4.7 8.7
Difference in delivery mm3/st.   2
Basic   *
Governor adjustment_02
Pump speed r/min   390 390 390
Average injection quantity mm3/st.   6.7 4.7 8.7
Governor adjustment_03
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   3
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   80 60 100
Basic   *
Speed control lever angle
Pump speed r/min   390 390 390
Average injection quantity mm3/st.   0 0 0
Remarks
Magnet OFF
 
0000000901
Pump speed r/min   1600 1600 1600
Overflow quantity with S/T OFF cm3/min   530 400 660
Stop lever angle
Pump speed r/min   1600 1600 1600
Pressure kPa   510 490 530
Pressure kgf/cm2   5.2 5 5.4
Basic   *
Stop lever angle_02
Pump speed r/min   1000 1000 1000
Pressure with S/T OFF kPa   313.5 284 343
Pressure with S/T OFF kgf/cm2   3.2 2.9 3.5
Stop lever angle_03
Pump speed r/min   1600 1600 1600
Pressure with S/T OFF kPa   510 490 530
Pressure with S/T OFF kgf/cm2   5.2 5 5.4
Stop lever angle_04
Pump speed r/min   2000 2000 2000
Pressure with S/T OFF kPa   637.5 608 667
Pressure with S/T OFF kgf/cm2   6.5 6.2 6.8
0000001101
Pump speed r/min   1600 1600 1600
Timer stroke mm   3.9 3.7 4.1
Basic   *
_02
Pump speed r/min   700 700 700
Timer stroke with S/T ON mm   0.5 0.5
_03
Pump speed r/min   1600 1600 1600
Timer stroke with S/T OFF mm   3.9 3.6 4.2
_04
Pump speed r/min   1800 1800 1800
Timer stroke with S/T OFF mm   5.7 5.1 6.3
_05
Pump speed r/min   1950 1950 1950
Timer stroke with S/T OFF mm   7 6.6 7.4
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001501
Pump speed r/min   1000 1000 1000
Atmospheric pressure difference kPa   -21.9 -22.6 -21.2
Atmospheric pressure difference mmHg   -164 -169 -159
Decrease qty mm3/st.   4.3 3.3 5.3
Basic   *
_02
Pump speed r/min   1000 1000 1000
Atmospheric pressure difference kPa   -21.9 -22.6 -21.2
Atmospheric pressure difference mmHg   -164 -169 -159
Decrease qty mm3/st.   4.3 2.8 5.8
Timing setting
K dimension mm   2.8 2.7 2.9
KF dimension mm   5 4.9 5.1
MS dimension mm   1 0.9 1.1
Pre-stroke mm   0.45 0.43 0.47
Control lever angle alpha deg.   18 14 22
Control lever angle beta deg.   31 26 36

Test data Ex:

0000001501 ANEROID COMPENSATOR

Test data 104741-6080
ACS adjustment Full load injection quantity at high altitudes and ACS adjusting method 1. Full load injection quantity adjustment (1)Remove the ACS cover and remove the bellows and adjusting shim. (2)Perform all adjustments as per the adjustment standard except for ACS adjustment. 2. ACS adjustment (1)Assemble the ACS cover, bellows and adjusting shim. (2)At pump speed N1, adjust using a shim to obtain the decrease for the altitude shown in the table. X1 = atmospheric pressure X2 = altitude Y = decrease quantity (A) = adjustment value (B) = test value
----------
N1=1000r/min
----------




Have questions with 104741-6080?





Group cross 104741-6080 ZEXEL

Isuzu 

 
8943361020 
INJECTION-PUMP ASSEMBLY
4JB1
 
8943382800 
INJECTION-PUMP ASSEMBLY
4JB1
 
8943382810 
INJECTION-PUMP ASSEMBLY
4JB1
 
8943272550 
INJECTION-PUMP ASSEMBLY
4JA1-EXP
 
8943272560 
INJECTION-PUMP ASSEMBLY
4JA1-EXP
 
8943272580 
INJECTION-PUMP ASSEMBLY
4JA1-EXP
 
8943272590 
INJECTION-PUMP ASSEMBLY
4JA1-EXP
 
8943272620 
INJECTION-PUMP ASSEMBLY
4JB1
104741-6080  

104741-6430 
 
8943272630 
INJECTION-PUMP ASSEMBLY
4JB1
 
8943272640 
INJECTION-PUMP ASSEMBLY
4JB1
Back to top