Rating:
Information injection-pump assembly
ZEXEL
104741-1861
1047411861
ISUZU
8944752121
8944752121
Cross reference number
ZEXEL
104741-1861
1047411861
ISUZU
8944752121
8944752121
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Pump speed
r/min
1150
1150
1150
Average injection quantity
mm3/st.
42.1
41.6
42.6
Difference in delivery
mm3/st.
3.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2400
2400
2400
Average injection quantity
mm3/st.
16.1
12.6
19.6
Injection timing adjustment_03
Pump speed
r/min
2000
2000
2000
Average injection quantity
mm3/st.
42
38.5
45.5
Injection timing adjustment_04
Pump speed
r/min
1150
1150
1150
Average injection quantity
mm3/st.
42.1
41.1
43.1
Injection timing adjustment_05
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
32.2
29.7
34.7
Injection timing adjustment_06
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
27.3
23.8
30.8
Injection quantity adjustment
Pump speed
r/min
2400
2400
2400
Average injection quantity
mm3/st.
16.1
13.1
19.1
Difference in delivery
mm3/st.
4.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2500
2500
2500
Average injection quantity
mm3/st.
12
Governor adjustment
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
6
4
8
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
6
4
8
Governor adjustment_03
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
80
60
100
Basic
*
Speed control lever angle
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1600
1600
1600
Overflow quantity
cm3/min
430
300
560
Stop lever angle
Pump speed
r/min
1600
1600
1600
Pressure
kPa
490.5
471
510
Pressure
kgf/cm2
5
4.8
5.2
Basic
*
Stop lever angle_02
Pump speed
r/min
1150
1150
1150
Pressure
kPa
372.5
343
402
Pressure
kgf/cm2
3.8
3.5
4.1
Stop lever angle_03
Pump speed
r/min
1600
1600
1600
Pressure
kPa
490.5
471
510
Pressure
kgf/cm2
5
4.8
5.2
Stop lever angle_04
Pump speed
r/min
2000
2000
2000
Pressure
kPa
608
579
637
Pressure
kgf/cm2
6.2
5.9
6.5
0000001101
Pump speed
r/min
1600
1600
1600
Timer stroke
mm
5.5
5.3
5.7
Basic
*
_02
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1
0.4
1.6
_03
Pump speed
r/min
1600
1600
1600
Timer stroke
mm
5.5
5.2
5.8
_04
Pump speed
r/min
2000
2000
2000
Timer stroke
mm
7.8
7.4
8.2
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001501
Pump speed
r/min
1150
1150
1150
Atmospheric pressure difference
kPa
-21.9
-22.6
-21.2
Atmospheric pressure difference
mmHg
-164
-169
-159
Decrease qty
mm3/st.
7.5
6.5
8.5
Basic
*
_02
Pump speed
r/min
1150
1150
1150
Atmospheric pressure difference
kPa
-21.9
-22.6
-21.2
Atmospheric pressure difference
mmHg
-164
-169
-159
Decrease qty
mm3/st.
7.5
6
9
Timing setting
K dimension
mm
2.8
2.7
2.9
KF dimension
mm
5.5
5.4
5.6
MS dimension
mm
1
0.9
1.1
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
18
14
22
Control lever angle beta
deg.
37
32
42
Test data Ex:
0000001501 ANEROID COMPENSATOR
ACS adjustment
Full load injection quantity at high altitudes and ACS adjusting method
1. Full load injection quantity adjustment
(1)Remove the ACS cover and remove the bellows and adjusting shim.
(2)Perform all adjustments as per the adjustment standard except for ACS adjustment.
2. ACS adjustment
(1)Assemble the ACS cover, bellows and adjusting shim.
(2)At pump speed N1, adjust using a shim to obtain the decrease for the altitude shown in the table.
X1 = atmospheric pressure
X2 = altitude
Y = decrease quantity
(A) = adjustment value
(B) = test value
----------
N1=1150r/min
----------
----------
N1=1150r/min
----------