Rating:
Information injection-pump assembly
ZEXEL
104741-1741
1047411741
ISUZU
8944751612
8944751612
Cross reference number
ZEXEL
104741-1741
1047411741
ISUZU
8944751612
8944751612
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
(Solenoid timer adjustment condition)
OFF
Injection timing adjustment
Pump speed
r/min
900
900
900
Boost pressure
kPa
46.65
45.3
48
Boost pressure
mmHg
350
340
360
Average injection quantity
mm3/st.
51.4
50.9
51.9
Difference in delivery
mm3/st.
4.5
Basic
*
Remarks
CBS
CBS
Injection timing adjustment_02
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
63.7
63.2
64.2
Difference in delivery
mm3/st.
3.5
Basic
*
Remarks
Full
Full
Injection timing adjustment_03
Pump speed
r/min
2300
2300
2300
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
22.3
18.8
25.8
Injection timing adjustment_04
Pump speed
r/min
1800
1800
1800
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
58.1
54.6
61.6
Injection timing adjustment_05
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
63.7
62.7
64.7
Remarks
Full
Full
Injection timing adjustment_06
Pump speed
r/min
900
900
900
Boost pressure
kPa
46.65
45.3
48
Boost pressure
mmHg
350
340
360
Average injection quantity
mm3/st.
51.4
50.4
52.4
Remarks
CBS
CBS
Injection timing adjustment_07
Pump speed
r/min
750
750
750
Boost pressure
kPa
24
22.7
25.3
Boost pressure
mmHg
180
170
190
Average injection quantity
mm3/st.
40.7
38.7
42.7
Injection timing adjustment_08
Pump speed
r/min
600
600
600
Boost pressure
kPa
13.35
12
14.7
Boost pressure
mmHg
100
90
110
Average injection quantity
mm3/st.
37.1
33.1
41.1
Injection quantity adjustment
Pump speed
r/min
2300
2300
2300
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
22.35
19.3
25.4
Difference in delivery
mm3/st.
4.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2500
2500
2500
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Average injection quantity
mm3/st.
5
Governor adjustment
Pump speed
r/min
385
385
385
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
5.1
3.1
7.1
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
385
385
385
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
5.1
3.1
7.1
Governor adjustment_03
Pump speed
r/min
500
500
500
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
80
60
100
Basic
*
Speed control lever angle
Pump speed
r/min
385
385
385
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1700
1700
1700
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Overflow quantity with S/T OFF
cm3/min
669
438
900
Stop lever angle
Pump speed
r/min
1700
1700
1700
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Pressure
kPa
529.5
510
549
Pressure
kgf/cm2
5.4
5.2
5.6
Basic
*
Stop lever angle_02
Pump speed
r/min
500
500
500
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Pressure with S/T ON
kPa
490
392
588
Pressure with S/T ON
kgf/cm2
5
4
6
Pressure with S/T OFF
kPa
78
78
Pressure with S/T OFF
kgf/cm2
0.8
0.8
Stop lever angle_03
Pump speed
r/min
1450
1450
1450
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Pressure with S/T OFF
kPa
451.5
422
481
Pressure with S/T OFF
kgf/cm2
4.6
4.3
4.9
Stop lever angle_04
Pump speed
r/min
1700
1700
1700
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Pressure with S/T OFF
kPa
529.5
510
549
Pressure with S/T OFF
kgf/cm2
5.4
5.2
5.6
Stop lever angle_05
Pump speed
r/min
1850
1850
1850
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Pressure with S/T OFF
kPa
578.5
549
608
Pressure with S/T OFF
kgf/cm2
5.9
5.6
6.2
0000001101
Pump speed
r/min
1700
1700
1700
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Timer stroke
mm
5.2
5
5.4
Basic
*
_02
Pump speed
r/min
550
550
550
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Timer stroke with S/T ON
mm
0.5
0.5
_03
Pump speed
r/min
1450
1450
1450
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Timer stroke with S/T OFF
mm
2.5
2.1
2.9
_04
Pump speed
r/min
1700
1700
1700
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Timer stroke with S/T OFF
mm
5.2
4.9
5.5
_05
Pump speed
r/min
1850
1850
1850
Boost pressure
kPa
80
78.7
81.3
Boost pressure
mmHg
600
590
610
Timer stroke with S/T OFF
mm
6.15
5.8
6.5
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
2.8
2.7
2.9
KF dimension
mm
5.5
5.4
5.6
MS dimension
mm
0.9
0.8
1
BCS stroke
mm
4.5
4.4
4.6
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
18
14
22
Control lever angle beta
deg.
37
32
42
Test data Ex:
0000001801 MICROSWITCH ADJUSTMENT
Microswitch adjustment
1. Insert a shim L mm (control lever position: a) between the control lever and the idling stopper bolt.
2. Move the microswitch in the direction of the arrow so that it turns ON.
3. Move the microswitch again in the direction of the arrow and tighten the microswitch fixing bolt where it turns OFF.
Must change from ON to OFF at L1. [Lever angle b (from idle).]
(A): microswitch fixing bolt
----------
L=6.0+-0.2mm a=14deg L1=5.6~6.4mm b=13~15deg
----------
T=2~3N-m(0.2~0.3kgf-m) L=6.0mm
----------
L=6.0+-0.2mm a=14deg L1=5.6~6.4mm b=13~15deg
----------
T=2~3N-m(0.2~0.3kgf-m) L=6.0mm
0000001901 V-FICD ADJUSTMENT
Adjustment of the V-FICD
1. Adjust the actuator rod to obtain S1.
2. Apply negative pressure P1 kPa {P2 mmHg} to the actuator and confirm that it moves through its full stroke.
(A) Control lever (Idling position)
----------
S1=1+1mm P1=-53.3kPa P2=-400mmHg
----------
S1=1+1mm
----------
S1=1+1mm P1=-53.3kPa P2=-400mmHg
----------
S1=1+1mm