104741-1531 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047411531 8944752180


104741-1531 INJECTION-PUMP ASSEMBLY
Rating:
10
Buy INJECTION-PUMP ASSEMBLY 104741-1531 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104741-1531 1047411531
ISUZU 8944752180 8944752180

Cross reference number

ZEXEL 104741-1531 1047411531
ISUZU 8944752180 8944752180


Zexel num
Bosch num
Firm num
Name
104741-1531 
104741-1535 
 
8944752180  ISUZU
INJECTION-PUMP ASSEMBLY
4JA1CG *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   42.1 41.6 42.6
Difference in delivery mm3/st.   3.5
Basic   *
Injection timing adjustment_02
Pump speed r/min   2400 2400 2400
Average injection quantity mm3/st.   16.1 12.6 19.6
Injection timing adjustment_03
Pump speed r/min   2000 2000 2000
Average injection quantity mm3/st.   42 38.5 45.5
Injection timing adjustment_04
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   42.1 41.1 43.1
Injection timing adjustment_05
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   32.2 29.7 34.7
Injection timing adjustment_06
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   27.3 23.8 30.8
Injection quantity adjustment
Pump speed r/min   2400 2400 2400
Average injection quantity mm3/st.   16.1 13.1 19.1
Difference in delivery mm3/st.   4.5
Basic   *
Injection quantity adjustment_02
Pump speed r/min   2500 2500 2500
Average injection quantity mm3/st.   12
Governor adjustment
Pump speed r/min   375 375 375
Average injection quantity mm3/st.   6 4 8
Difference in delivery mm3/st.   2
Basic   *
Governor adjustment_02
Pump speed r/min   375 375 375
Average injection quantity mm3/st.   6 4 8
Governor adjustment_03
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   3
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   80 60 100
Basic   *
Speed control lever angle
Pump speed r/min   375 375 375
Average injection quantity mm3/st.   0 0 0
0000000901
Pump speed r/min   1600 1600 1600
Overflow quantity with S/T OFF cm3/min   530 400 660
Stop lever angle
Pump speed r/min   1600 1600 1600
Pressure with S/T OFF kPa   490.5 471 510
Pressure with S/T OFF kgf/cm2   5 4.8 5.2
Basic   *
Stop lever angle_02
Pump speed r/min   1150 1150 1150
Pressure with S/T OFF kPa   372.5 343 402
Pressure with S/T OFF kgf/cm2   3.8 3.5 4.1
Stop lever angle_03
Pump speed r/min   1600 1600 1600
Pressure with S/T OFF kPa   490.5 471 510
Pressure with S/T OFF kgf/cm2   5 4.8 5.2
Stop lever angle_04
Pump speed r/min   2000 2000 2000
Pressure with S/T OFF kPa   608 579 637
Pressure with S/T OFF kgf/cm2   6.1 5.9 6.3
0000001101
Pump speed r/min   1600 1600 1600
Timer stroke with S/T OFF mm   5.5 5.3 5.7
Basic   *
_02
Pump speed r/min   670 670 670
Timer stroke with S/T ON mm   0.5 0.5
_03
Pump speed r/min   1000 1000 1000
Timer stroke with S/T OFF mm   1 0.4 1.6
_04
Pump speed r/min   1600 1600 1600
Timer stroke with S/T OFF mm   5.5 5.2 5.8
_05
Pump speed r/min   2000 2000 2000
Timer stroke with S/T OFF mm   7.8 7.4 8.2
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001501
Pump speed r/min   1150 1150 1150
Atmospheric pressure difference kPa   -21.9 -22.6 -21.2
Atmospheric pressure difference mmHg   -164 -169 -159
Decrease qty mm3/st.   7.5 6.5 8.5
Basic   *
_02
Pump speed r/min   1150 1150 1150
Atmospheric pressure difference kPa   -21.9 -22.6 -21.2
Atmospheric pressure difference mmHg   -164 -169 -159
Decrease qty mm3/st.   7.5 6 9
Timing setting
K dimension mm   2.8 2.7 2.9
KF dimension mm   5.5 5.4 5.6
MS dimension mm   1 0.9 1.1
Pre-stroke mm   0.45 0.43 0.47
Control lever angle alpha deg.   18 14 22
Control lever angle beta deg.   37 32 42

Test data Ex:

0000001501 ANEROID COMPENSATOR

Test data 104741-1531
ACS adjustment Full load injection quantity at high altitudes and ACS adjusting method 1. Full load injection quantity adjustment (1)Remove the ACS cover and remove the bellows and adjusting shim. (2)Perform all adjustments as per the adjustment standard except for ACS adjustment. 2. ACS adjustment (1)Assemble the ACS cover, bellows and adjusting shim. (2)At pump speed N1, adjust using a shim to obtain the decrease for the altitude shown in the table. X1 = atmospheric pressure X2 = altitude Y = decrease quantity (A) = adjustment value (B) = test value
----------
N1=1150r/min
----------




Have questions with 104741-1531?





Group cross 104741-1531 ZEXEL

Isuzu 

 
 
INJECTION-PUMP ASSEMBLY
4JA1CG
104741-1531  

104741-1535 
 
8944752180 
INJECTION-PUMP ASSEMBLY
4JA1CG
 
8944752181 
INJECTION-PUMP ASSEMBLY
4JA1CG
 
8944752182 
INJECTION-PUMP ASSEMBLY
4JA1CG
9 460 612 135 
8944752183 
INJECTION-PUMP ASSEMBLY
4JA1CG
Back to top