Rating:
Information injection-pump assembly
ZEXEL
104741-1021
1047411021
ISUZU
8941337561
8941337561
Cross reference number
ZEXEL
104741-1021
1047411021
ISUZU
8941337561
8941337561
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
(Solenoid timer adjustment condition)
OFF OFF
OFF OFF
Timer measuring device installation position
Low pressure side LOW PRESSURE SIDE
Low pressure side LOW PRESSURE SIDE
Injection timing adjustment
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
44.6
44.1
45.1
Difference in delivery
mm3/st.
3.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
2100
2100
2100
Average injection quantity
mm3/st.
12.8
9.3
16.3
Injection timing adjustment_03
Pump speed
r/min
1700
1700
1700
Average injection quantity
mm3/st.
47.3
44.8
49.8
Injection timing adjustment_04
Pump speed
r/min
1350
1350
1350
Average injection quantity
mm3/st.
47.5
45.5
49.5
Injection timing adjustment_05
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
44.6
43.6
45.6
Injection timing adjustment_06
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
36.6
34.6
38.6
Injection timing adjustment_07
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
44.35
40.8
47.9
Injection quantity adjustment
Pump speed
r/min
2100
2100
2100
Average injection quantity
mm3/st.
12.7
9.6
15.8
Difference in delivery
mm3/st.
3.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2300
2300
2300
Average injection quantity
mm3/st.
7
Governor adjustment
Pump speed
r/min
390
390
390
Average injection quantity
mm3/st.
9
7
11
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
390
390
390
Average injection quantity
mm3/st.
9
7
11
Governor adjustment_03
Pump speed
r/min
550
550
550
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
95
75
115
Basic
*
Speed control lever angle
Pump speed
r/min
390
390
390
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1550
1550
1550
Overflow quantity with S/T OFF
cm3/min
531
402
660
Remarks
OFF
OFF
Stop lever angle
Pump speed
r/min
1550
1550
1550
Pressure
kPa
519.5
500
539
Pressure
kgf/cm2
5.3
5.1
5.5
Basic
*
Stop lever angle_02
Pump speed
r/min
1000
1000
1000
Pressure
kPa
313.5
284
343
Pressure
kgf/cm2
3.2
2.9
3.5
Stop lever angle_03
Pump speed
r/min
1550
1550
1550
Pressure
kPa
519.5
500
539
Pressure
kgf/cm2
5.3
5.1
5.5
Stop lever angle_04
Pump speed
r/min
1850
1850
1850
Pressure
kPa
617.5
588
647
Pressure
kgf/cm2
6.3
6
6.6
0000001101
Pump speed
r/min
1550
1550
1550
Timer stroke
mm
1.9
1.7
2.1
Basic
*
_02
Pump speed
r/min
730
630
830
Timer stroke with S/T ON
mm
0.5
0.5
0.5
_03
Pump speed
r/min
1440
1390
1490
Timer stroke with S/T OFF
mm
0.5
0.5
0.5
_04
Pump speed
r/min
1550
1550
1550
Timer stroke with S/T OFF
mm
1.9
1.6
2.2
_05
Pump speed
r/min
1850
1850
1850
Timer stroke with S/T OFF
mm
5.7
5.3
6.1
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
2.8
2.7
2.9
KF dimension
mm
5
4.9
5.1
MS dimension
mm
1
0.9
1.1
Pre-stroke
mm
0.45
0.43
0.47
Control lever angle alpha
deg.
18
14
22
Control lever angle beta
deg.
35
31
39