104740-9840 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047409840 1670021t07


104740-9840 INJECTION-PUMP ASSEMBLY
Rating:
23
Buy INJECTION-PUMP ASSEMBLY 104740-9840 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104740-9840 1047409840
NISSAN-DIESEL 1670021T07 1670021t07

Cross reference number

ZEXEL 104740-9840 1047409840
NISSAN-DIESEL 1670021T07 1670021t07


Zexel num
Bosch num
Firm num
Name
104740-9840 
104740-9841 
 
1670021T07  NISSAN-DIESEL
INJECTION-PUMP ASSEMBLY
TD23 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105000-2010
Bosch type code   NP-DN12SD12TT
Nozzle holder   105780-2080
Opening pressure MPa   14.7 14.7 15.19
Opening pressure kgf/cm2   150 150 155
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-840
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   44.6 44.1 45.1
Difference in delivery mm3/st.   3
Basic   *
Injection timing adjustment_02
Pump speed r/min   2550 2550 2550
Average injection quantity mm3/st.   8.85 5.3 12.4
Injection timing adjustment_03
Pump speed r/min   2350 2350 2350
Average injection quantity mm3/st.   30.3 27.8 32.8
Injection timing adjustment_04
Pump speed r/min   2150 2150 2150
Average injection quantity mm3/st.   38 35.9 40.1
Injection timing adjustment_05
Pump speed r/min   1100 1100 1100
Average injection quantity mm3/st.   44.6 43.6 45.6
Injection timing adjustment_06
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   43.5 41.5 45.5
Injection quantity adjustment
Pump speed r/min   2350 2350 2350
Average injection quantity mm3/st.   30.3 28.3 32.3
Basic   *
Injection quantity adjustment_02
Pump speed r/min   2700 2700 2700
Average injection quantity mm3/st.   5
Governor adjustment
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   6.5 4.5 8.5
Difference in delivery mm3/st.   2
Basic   *
Governor adjustment_02
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   6.5 4.5 8.5
Governor adjustment_03
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   3
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   62.5 45 80
Basic   *
Speed control lever angle
Pump speed r/min   350 350 350
Average injection quantity mm3/st.   0 0 0
Remarks
Magnet OFF
 
0000000901
Pump speed r/min   1100 1100 1100
Overflow quantity cm3/min   390 258 522
Stop lever angle
Pump speed r/min   1100 1100 1100
Pressure kPa   431.5 402 461
Pressure kgf/cm2   4.4 4.1 4.7
Basic   *
Stop lever angle_02
Pump speed r/min   1100 1100 1100
Pressure kPa   431.5 402 461
Pressure kgf/cm2   4.4 4.1 4.7
Stop lever angle_03
Pump speed r/min   1700 1700 1700
Pressure kPa   578.5 549 608
Pressure kgf/cm2   5.9 5.6 6.2
Stop lever angle_04
Pump speed r/min   2150 2150 2150
Pressure kPa   676.5 647 706
Pressure kgf/cm2   6.9 6.6 7.2
0000001101
Pump speed r/min   1100 1100 1100
Timer stroke mm   2.5 2.3 2.7
Basic   *
_02
Pump speed r/min   1100 1100 1100
Timer stroke mm   2.5 2.2 2.8
_03
Pump speed r/min   1700 1700 1700
Timer stroke mm   4.6 4 5.2
_04
Pump speed r/min   2550 2550 2550
Timer stroke mm   6.9 6.4 7.4
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001501
Pump speed r/min   1100 1100 1100
Atmospheric pressure difference kPa   -21.9 -22.6 -21.2
Atmospheric pressure difference mmHg   -164 -169 -159
Average injection quantity mm3/st.   34.5 33 36
Basic   *
_02
Pump speed r/min   1100 1100 1100
Atmospheric pressure difference kPa   -21.9 -22.6 -21.2
Atmospheric pressure difference mmHg   -164 -169 -159
Average injection quantity mm3/st.   34.5 32.5 36.5
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   5.8 5.7 5.9
MS dimension mm   1 0.9 1.1
Control lever angle alpha deg.   54 50 58
Control lever angle beta deg.   36 31 41

Test data Ex:

0000001501 ANEROID COMPENSATOR

Test data 104740-9840
ACS adjustment Full load injection quantity at high altitudes and ACS adjusting method 1. Full load injection quantity adjustment (1)Remove the ACS cover and remove the bellows and adjusting shim. (2)Perform all adjustments as per the adjustment standard except for ACS adjustment. 2. ACS adjustment (1)Assemble the ACS cover, bellows and adjusting shim. (2)At pump speed N1, adjust using a shim to obtain the decrease for the altitude shown in the table. X1 = atmospheric pressure X2 = altitude Y = decrease quantity (A) = adjustment value (B) = test value
----------
N1=1100r/min
----------

0000001801 CONTROL LEVER ANGLE

Test data 104740-9840
Control lever angle measurement 1. Measure dimension L between the end of the lever and the flange face. 2. Measure the lever angle from the pin hole R (plate). (A) = lever angle measuring position (B) = flange face
----------
L=10.7~14.2mm R=49mm
----------
L=10.7~14.2mm R=49mm




Have questions with 104740-9840?





Group cross 104740-9840 ZEXEL

Nissan-Diesel 

9 460 614 338 
1670021T03 
INJECTION-PUMP ASSEMBLY
TD23
 
1670021T04 
INJECTION-PUMP ASSEMBLY
TD23
9 460 610 436 
1670021T08 
INJECTION-PUMP ASSEMBLY
TD23
 
1670021T05 
INJECTION-PUMP ASSEMBLY
TD23
9 460 614 339 
1670021T09 
INJECTION-PUMP ASSEMBLY
TD23
 
1670021T06 
INJECTION-PUMP ASSEMBLY
TD23
9 460 614 340 
1670021T10 
INJECTION-PUMP ASSEMBLY
TD23
104740-9840  

104740-9841 
 
1670021T07 
INJECTION-PUMP ASSEMBLY
TD23
9 460 614 341 
1670021T11 
INJECTION-PUMP ASSEMBLY
TD23
9 460 610 341 
1670002N74 
INJECTION-PUMP ASSEMBLY
TD23
9 460 610 735 
1670002N75 
INJECTION-PUMP ASSEMBLY
TD23
9 460 610 388 
1670010T11 
INJECTION-PUMP ASSEMBLY
TD23
 
1670022T00 
INJECTION-PUMP ASSEMBLY
TD27
9 460 612 947 
1670022T04 
INJECTION-PUMP ASSEMBLY
TD27
 
1670022T01 
INJECTION-PUMP ASSEMBLY
TD27
9 460 612 948 
1670022T05 
INJECTION-PUMP ASSEMBLY
TD27
Back to top