Rating:
Information injection-pump assembly
BOSCH
9 460 610 137
9460610137
ZEXEL
104740-4570
1047404570
Cross reference number
BOSCH
9 460 610 137
9460610137
ZEXEL
104740-4570
1047404570
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
(Note)
For Japan: year/month/day (change sequence) 1987/04/16 (2)
For Japan: year/month/day (change sequence) 1987/04/16 (2)
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
36.1
35.6
36.6
Difference in delivery
mm3/st.
3
Basic
*
Remarks
For Japan
For Japan
Injection timing adjustment_02
Pump speed
r/min
2450
2450
2450
Average injection quantity
mm3/st.
12.1
8.1
16.1
Remarks
For Japan
For Japan
Injection timing adjustment_03
Pump speed
r/min
2150
2150
2150
Average injection quantity
mm3/st.
33.9
31.9
35.9
Remarks
For Japan
For Japan
Injection timing adjustment_04
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
36.1
35.1
37.1
Remarks
For Japan
For Japan
Injection timing adjustment_05
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
32.3
30.3
34.3
Remarks
For Japan
For Japan
Injection quantity adjustment
Pump speed
r/min
2450
2450
2450
Average injection quantity
mm3/st.
12.1
8.6
15.6
Basic
*
Remarks
For Japan
For Japan
Injection quantity adjustment_02
Pump speed
r/min
2600
2600
2600
Average injection quantity
mm3/st.
5
Remarks
For Japan
For Japan
Governor adjustment
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
6.3
4.3
8.3
Difference in delivery
mm3/st.
2
Basic
*
Remarks
For Japan
For Japan
Governor adjustment_02
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
6.3
4.3
8.3
Remarks
For Japan
For Japan
Governor adjustment_03
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
3
Remarks
For Japan
For Japan
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
72.5
55
90
Basic
*
Remarks
For Japan
For Japan
Speed control lever angle
Pump speed
r/min
300
300
300
Average injection quantity
mm3/st.
0
0
0
Remarks
For Japan: Magnet OFF
For Japan: Magnet OFF
0000000901
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
378
246
510
Remarks
For Japan
For Japan
Stop lever angle
Pump speed
r/min
1000
1000
1000
Pressure
kPa
411.5
382
441
Pressure
kgf/cm2
4.2
3.9
4.5
Basic
*
Remarks
For Japan
For Japan
Stop lever angle_02
Pump speed
r/min
1000
1000
1000
Pressure
kPa
411.5
382
441
Pressure
kgf/cm2
4.2
3.9
4.5
Remarks
For Japan
For Japan
Stop lever angle_03
Pump speed
r/min
1400
1400
1400
Pressure
kPa
510
481
539
Pressure
kgf/cm2
5.2
4.9
5.5
Remarks
For Japan
For Japan
Stop lever angle_04
Pump speed
r/min
2150
2150
2150
Pressure
kPa
696.5
667
726
Pressure
kgf/cm2
7.1
6.8
7.4
Remarks
For Japan
For Japan
0000001101
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1.7
1.5
1.9
Basic
*
Remarks
For Japan
For Japan
_02
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
1.7
1.4
2
Remarks
For Japan
For Japan
_03
Pump speed
r/min
1400
1400
1400
Timer stroke
mm
3.2
2.6
3.8
Remarks
For Japan
For Japan
_04
Pump speed
r/min
2150
2150
2150
Timer stroke
mm
6.2
5.6
6.8
Remarks
For Japan
For Japan
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.75
5.65
5.85
MS dimension
mm
1.5
1.4
1.6
Pre-stroke
mm
0.2
0.18
0.22
Control lever angle alpha
deg.
25
21
29
Control lever angle beta
deg.
46
41
51