104740-2204 ZEXEL 9 460 610 514 BOSCH INJECTION-PUMP ASSEMBLY 9460610514 1047402204


104740-2204 INJECTION-PUMP ASSEMBLY
Rating:
23
Buy INJECTION-PUMP ASSEMBLY 104740-2204 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 460 610 514 9460610514
ZEXEL 104740-2204 1047402204

Cross reference number

BOSCH 9 460 610 514 9460610514
ZEXEL 104740-2204 1047402204


Zexel num
Bosch num
Firm num
Name
104740-2204 
104740-2205 
9 460 610 514 
   
INJECTION-PUMP ASSEMBLY
* K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Pump speed r/min   1400 1400 1400
Average injection quantity mm3/st.   36.6 36.2 37
Difference in delivery mm3/st.   3
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   32.3 29.8 34.8
Oil temperature degC   50 48 52
Injection timing adjustment_03
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   31.9 29.4 34.4
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   1400 1400 1400
Average injection quantity mm3/st.   36.6 35.6 37.6
Difference in delivery mm3/st.   3.5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_05
Pump speed r/min   1800 1800 1800
Average injection quantity mm3/st.   37.5 35 40
Oil temperature degC   50 48 52
Injection quantity adjustment
Pump speed r/min   2700 2700 2700
Average injection quantity mm3/st.   14 12 16
Difference in delivery mm3/st.   4.5
Basic   *
Oil temperature degC   55 52 58
Injection quantity adjustment_02
Pump speed r/min   2800 2800 2800
Average injection quantity mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2400 2400 2400
Average injection quantity mm3/st.   37.1 34.1 40.1
Oil temperature degC   52 50 54
Governor adjustment
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   10.5 9.5 11.5
Difference in delivery mm3/st.   2
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   10.5 8.5 12.5
Difference in delivery mm3/st.   2.5
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_03
Pump speed r/min   750 750 750
Average injection quantity mm3/st.   5
Oil temperature degC   50 48 52
Boost compensator adjustment
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   18 11.5 24.5
Oil temperature degC   50 48 52
Lever angle (shim thickness) mm   5.9 5.9 5.9
Remarks
From idle
 
Boost compensator adjustment_02
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   14.2 7.2 21.2
Oil temperature degC   50 48 52
Lever angle (shim thickness) mm   5.9 5.9 5.9
Remarks
From idle
 
Timer adjustment
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   60 50 70
Basic   *
Oil temperature degC   48 46 50
Remarks
Full
 
Speed control lever angle
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF at idling position
 
0000000901
Pump speed r/min   1000 1000 1000
Overflow quantity cm3/min   390 260 520
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   1000 1000 1000
Pressure kPa   412 383 441
Pressure kgf/cm2   4.2 3.9 4.5
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_02
Pump speed r/min   1000 1000 1000
Pressure kPa   412.5 375 450
Pressure kgf/cm2   4.2 3.8 4.6
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_03
Pump speed r/min   1800 1800 1800
Pressure kPa   588.5 549 628
Pressure kgf/cm2   6 5.6 6.4
Oil temperature degC   50 48 52
Stop lever angle_04
Pump speed r/min   2400 2400 2400
Pressure kPa   735.5 686 785
Pressure kgf/cm2   7.5 7 8
Oil temperature degC   52 50 54
0000001101
Pump speed r/min   1000 1000 1000
Timer stroke mm   3.1 2.9 3.3
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   1000 1000 1000
Timer stroke mm   3.1 2.8 3.4
Basic   *
Oil temperature degC   50 48 52
_03
Pump speed r/min   1800 1800 1800
Timer stroke mm   6.8 6.3 7.3
Oil temperature degC   50 48 52
_04
Pump speed r/min   2400 2400 2400
Timer stroke mm   8.55 8.1 9
Oil temperature degC   52 50 54
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   6.78 6.68 6.88
MS dimension mm   0.8 0.7 0.9
Control lever angle alpha deg.   25 23 27
Control lever angle beta deg.   42 37 47

Test data Ex:

0000001801 W-CSD ADJUSTMENT

Test data 104740-2204
Adjustment of the W-CSD 1. Adjustment of the advance angle of the timer (1)Determine the timer advance angle from the graph in Fig. 3 (Q). (2)(1) Adjust using the screw (I) so that the timer advance angle determined in item (1) is obtained. 2. Setting the intermediate lever position (refer to fig 1 and fig 2) (1)Insert a block gauge L1 between the idling set screw (H) and the control lever (G). (2)Insert a shim of thickness L2 mm between the intermediate lever (D) and the intermediate lever bracket (E). Ensure the screw (F) contacts the control lever (G), then fix the nut. 3. W-CSD lever adjustment [refer to fig 1 (O) and fig 2 (P)] (1)After completing (2) above, remove the block gauge L3 and the shim with the thickness L4. (2)Insert a block gauge L5 determined from the graph (L-theta) in figure 3 (Q) between the idling set screw (H) and the control lever (G). (3)Adjust the screw (B) until the screw (F) contacts the control lever (G). Then fix locknut (A). Note: The temperature of the wax at adjustment must not exceed a. X:Temperature theta (deg C) Y1:Timer stroke TA (mm) Y2:Control lever L dimension (mm; control lever position) J:TA-theta line theta (deg C) <= 10: TA = 1.23 10 <= theta (deg C) <= 20: TA = -0.012 theta + 1.35 20 <= theta (deg C) <= 53.6: TA = -0.0330 theta + 1.77 K:L-theta graph theta (deg C) <= 10: L = 3.9 10 <= theta (deg C) <= 20: L = -0.04 theta + 4.3 20 <= theta (deg C) <= 52.3: L = -0.108 theta + 5.66
----------
L1=3.5+-0.05mm L2=5.3+-0.05mm L3=3.5mm L4=5.3mm L5=L1+-0.05mm a=30degC
----------
L1=3.5+-0.05mm L4=5.3mm

0000001901 IDLING SWITCH ADJUSTMENT

Test data 104740-2204
Idle switch adjustment ON - OFF changeover point: from idle to a (shim thickness L) Idle-c: ON d ~ full speed: OFF (A) = idle lever position (B) = idle switch (potentiometer)
----------
a=5deg+-1deg c=5deg d=5deg L=3.3+-0.05mm
----------
a=5deg+-1deg b=(25deg+-2deg) L=3.3+-0.05mm SW=SW10mm T=6~9N-m{0.6~0.9kgf-m}




Have questions with 104740-2204?





Group cross 104740-2204 ZEXEL

9 460 610 500 
 
INJECTION-PUMP ASSEMBLY

Nissan 

9 460 610 942 
1670057J10 
INJECTION-PUMP ASSEMBLY
XM3
104740-2204  

104740-2205 
9 460 610 514 
 
INJECTION-PUMP ASSEMBLY

Nissan 

9 460 610 943 
1670057J12 
INJECTION-PUMP ASSEMBLY
XM3
9 460 610 551 
1670057J14 
INJECTION-PUMP ASSEMBLY
XM3
Back to top