Rating:
Information injection-pump assembly
ZEXEL
104740-1260
1047401260
ISUZU
8944192660
8944192660
Cross reference number
ZEXEL
104740-1260
1047401260
ISUZU
8944192660
8944192660
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
51.1
50.6
51.6
Difference in delivery
mm3/st.
4
Basic
*
Injection timing adjustment_02
Pump speed
r/min
750
750
750
Boost pressure
kPa
24
22.7
25.3
Boost pressure
mmHg
180
170
190
Average injection quantity
mm3/st.
42.1
41.6
42.6
Difference in delivery
mm3/st.
5
Basic
*
Injection timing adjustment_03
Pump speed
r/min
2600
2600
2600
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
17.6
16.1
19.1
Injection timing adjustment_04
Pump speed
r/min
2250
2250
2250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
41.6
38.6
44.6
Injection timing adjustment_05
Pump speed
r/min
2150
2150
2150
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
43.2
40.7
45.7
Injection timing adjustment_06
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
51.1
50.1
52.1
Injection timing adjustment_07
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
36.4
33.9
38.9
Injection timing adjustment_08
Pump speed
r/min
750
750
750
Boost pressure
kPa
24
22.7
25.3
Boost pressure
mmHg
180
170
190
Average injection quantity
mm3/st.
42.1
41.1
43.1
Injection timing adjustment_09
Pump speed
r/min
550
550
550
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
38.2
35.7
40.7
Injection quantity adjustment
Pump speed
r/min
2600
2600
2600
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
17.6
16.6
18.6
Difference in delivery
mm3/st.
5.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
2800
2800
2800
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
5
Governor adjustment
Pump speed
r/min
400
400
400
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
12.2
10.2
14.2
Difference in delivery
mm3/st.
2
Basic
*
Governor adjustment_02
Pump speed
r/min
400
400
400
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
12.2
10.2
14.2
Governor adjustment_03
Pump speed
r/min
475
475
475
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
3
Timer adjustment
Pump speed
r/min
100
100
100
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
77.5
60
95
Basic
*
Speed control lever angle
Pump speed
r/min
400
400
400
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
0000000901
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Overflow quantity
cm3/min
400
270
530
Stop lever angle
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Pressure
kPa
441.5
422
461
Pressure
kgf/cm2
4.5
4.3
4.7
Basic
*
Stop lever angle_02
Pump speed
r/min
600
600
600
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Pressure
kPa
255
226
284
Pressure
kgf/cm2
2.6
2.3
2.9
Stop lever angle_03
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Pressure
kPa
441.5
422
461
Pressure
kgf/cm2
4.5
4.3
4.7
Stop lever angle_04
Pump speed
r/min
1750
1750
1750
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Pressure
kPa
578.5
549
608
Pressure
kgf/cm2
5.9
5.6
6.2
Stop lever angle_05
Pump speed
r/min
2250
2250
2250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Pressure
kPa
730.5
686
775
Pressure
kgf/cm2
7.45
7
7.9
0000001101
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Timer stroke
mm
2.6
2.4
2.8
Basic
*
_02
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Timer stroke
mm
2.6
2.3
2.9
_03
Pump speed
r/min
1750
1750
1750
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Timer stroke
mm
5.2
4.6
5.8
_04
Pump speed
r/min
2250
2250
2250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Timer stroke
mm
7.8
7.4
8.2
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001401
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
30
29
31
Timer stroke variation dT
mm
1
0.8
1.2
Basic
*
_02
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
30
28.5
31.5
Timer stroke variation dT
mm
1
0.7
1.3
_03
Pump speed
r/min
1250
1250
1250
Boost pressure
kPa
60
58.7
61.3
Boost pressure
mmHg
450
440
460
Average injection quantity
mm3/st.
23
21.5
24.5
Timer stroke variation dT
mm
1.6
1.1
2.1
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.3
1.2
1.4
BCS stroke
mm
4.2
4.1
4.3
Control lever angle alpha
deg.
24.5
20.5
28.5
Control lever angle beta
deg.
45
40
50
Test data Ex:
0000001801 MICROSWITCH ADJUSTMENT
Microswitch adjustment
With the control lever a from the idle position (idle stopper lever clearance L1) and the microswitch ON, gradually move the microswitch and fix it in the position where the microswitch goes OFF.
(From the idle position the microswitch is on at a.)
----------
a=31.5+-1deg L1=10.3+-0.2mm
----------
----------
a=31.5+-1deg L1=10.3+-0.2mm
----------
0000001901 W-CSD ADJUSTMENT
Adjustment of the W-CSD
1. Adjustment of the timer stroke
Adjust using screw (A) so that the timer stroke is the value determined using the graph (M).
2. Adjustment of the position of the intermediate lever.
Insert a shim L1 between the control lever (I) and the idle set screw (G).
Align the intermediate lever (F) with the aligning line (J) and fix screw (E) so that it contacts the control lever.
3. Adjustment of the FICD
Insert a shim L2 between the control lever (I) and the idle set screw (G).
Use adjusting screw (B) to fix the CSD lever (C) in the position where it operates the intermediate lever via the rod (D).
S:Shims L1, L2
(M) Timer stroke (mm), (1) TA = -0.0215t+0.75
Lever position (deg) (2) theta = -0.1925t+7.71
Lever position (mm) (3) L = -0.0635t+2.52
(3 shows the gap between the control lever and the idle set screw.)
X = temperature (deg C)
Y1 = timer stroke (mm)
Y2 = control lever position (deg)
----------
L1=1.25+-0.05mm L2=L+-0.05mm
----------
S=L1=1.25+-0.05mm S=L2=L+-0.05mm
----------
L1=1.25+-0.05mm L2=L+-0.05mm
----------
S=L1=1.25+-0.05mm S=L2=L+-0.05mm