104740-0942 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1047400942 wl8113800a


104740-0942 INJECTION-PUMP ASSEMBLY
Rating:
52
Buy INJECTION-PUMP ASSEMBLY 104740-0942 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 104740-0942 1047400942
MAZDA WL8113800A wl8113800a

Cross reference number

ZEXEL 104740-0942 1047400942
MAZDA WL8113800A wl8113800a


Zexel num
Bosch num
Firm num
Name
104740-0942 
104740-0943 
 
WL8113800A  MAZDA
INJECTION-PUMP ASSEMBLY
WL-NA * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113orSAEJ967d
Test oil temperature degC   45 45 50
Nozzle   105780-0060
Bosch type code   NP-DN0SD1510
Nozzle holder   105780-2150
Opening pressure MPa   13 13 13.3
Opening pressure kgf/cm2   133 133 136
Injection pipe   157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm)
mm   2-6-450
Joint assembly   157641-4720
Tube assembly   157641-4020
Transfer pump pressure kPa   20 20 20
Transfer pump pressure kgf/cm2   0.2 0.2 0.2
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   48.7 48.2 49.2
Difference in delivery mm3/st.   4
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_02
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   44.8 41.8 47.8
Oil temperature degC   48 46 50
Injection timing adjustment_03
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   48.7 47.7 49.7
Difference in delivery mm3/st.   4.5
Basic   *
Oil temperature degC   50 48 52
Injection timing adjustment_04
Pump speed r/min   2100 2100 2100
Average injection quantity mm3/st.   44.3 40.8 47.8
Oil temperature degC   52 50 54
Injection quantity adjustment
Pump speed r/min   2450 2450 2450
Average injection quantity mm3/st.   15.7 12.7 18.7
Difference in delivery mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_02
Pump speed r/min   2800 2800 2800
Average injection quantity mm3/st.   5
Oil temperature degC   55 52 58
Injection quantity adjustment_03
Pump speed r/min   2450 2450 2450
Average injection quantity mm3/st.   15.7 5.7 25.7
Difference in delivery mm3/st.   5.5
Oil temperature degC   55 52 58
Governor adjustment
Pump speed r/min   360 360 360
Average injection quantity mm3/st.   9 8 10
Difference in delivery mm3/st.   1.7
Basic   *
Oil temperature degC   48 46 50
Governor adjustment_02
Pump speed r/min   360 360 360
Average injection quantity mm3/st.   9 7.5 10.5
Difference in delivery mm3/st.   2.2
Basic   *
Oil temperature degC   48 46 50
Boost compensator adjustment
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   17 15.5 18.5
Difference in delivery mm3/st.   2.5
Oil temperature degC   48 46 50
Boost compensator adjustment_02
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   17 15 19
Difference in delivery mm3/st.   2.5
Oil temperature degC   48 46 50
Timer adjustment
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   70 55 90
Oil temperature degC   48 46 50
Timer adjustment_02
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   70 50 90
Oil temperature degC   48 46 50
Speed control lever angle
Pump speed r/min   360 360 360
Average injection quantity mm3/st.   0 0 0
Oil temperature degC   48 46 50
Remarks
Magnet OFF
 
0000000901
Pump speed r/min   1250 1250 1250
Overflow quantity cm3/min   420 290 550
Oil temperature degC   50 48 52
Stop lever angle
Pump speed r/min   250 250 250
Pressure kPa   569 540 598
Pressure kgf/cm2   5.8 5.5 6.1
Basic   *
Oil temperature degC   50 48 52
Stop lever angle_02
Pump speed r/min   1250 1250 1250
Pressure kPa   569 530 608
Pressure kgf/cm2   5.8 5.4 6.2
Basic   *
Oil temperature degC   50 48 52
0000001101
Pump speed r/min   1250 1250 1250
Timer stroke mm   5.7 5.5 5.9
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   500 500 500
Timer stroke mm   1.8 1 2.6
Oil temperature degC   48 46 50
_03
Pump speed r/min   1250 1250 1250
Timer stroke mm   5.7 5.3 6.1
Basic   *
Oil temperature degC   50 48 52
_04
Pump speed r/min   2000 2000 2000
Timer stroke mm   9.2 8.4 10
Oil temperature degC   50 48 52
0000001201
Max. applied voltage V   8 8 8
Test voltage V   13 12 14
0000001401
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   33.6 33.1 34.1
Timer stroke TA mm   5.2 5 5.4
Timer stroke variation dT mm   0.5 0.5 0.5
Basic   *
Oil temperature degC   50 48 52
_02
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   33.6 32.6 34.6
Timer stroke TA mm   5.2 4.8 5.6
Timer stroke variation dT mm   0.5 0.5 0.5
Basic   *
Oil temperature degC   50 48 52
_03
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   25 23.5 26.5
Timer stroke TA mm   4.1 3.5 4.7
Timer stroke variation dT mm   1.6 1.6 1.6
Oil temperature degC   50 48 52
Timing setting
K dimension mm   3.3 3.2 3.4
KF dimension mm   6 5.9 6.1
MS dimension mm   0.9 0.8 1
Pre-stroke mm   0.03 0.01 0.05
Control lever angle alpha deg.   12.5 8.5 16.5
Control lever angle beta deg.   40 37 43

Test data Ex:

0000001801 CONTROL STANDARD AT IDLING

Test data 104740-0942
Standards for idle difference in delivery control After idle adjustment, measure the idle injection quantities of (A) to (D). Install the colored rings to the delivery valve holders (A) to (D) in accordance with the table. (A): A cylinder (B) :B cylinder (C) : C cylinder (D): D cylinder (E): Collar ring (F): (A) >= (C) (G): (C) > (A) (H): (A) - (C) or (C) - (A) (I): 0.2, 0.1(mm3/st) (J): (B) - (D) or (D) - (B) (K): Ring color (L): At least 0.6 mm3/st (M): 0.3, 0.4, 0.5 (mm3/st) (N): 0.2, 0.1, 0.0 (mm3/st) (O): (B) >= (D) (P): (D) > (B) (T): Yellow (U): White (V): Red
----------

----------

0000001901 WIRE

Test data 104740-0942
Confirmation of the wire length: Accelerator wire: Idle-full stroke: L1 Adjustment of the double stage actuator: (1)Apply negative pressure P1 {P2} to the actuator through the negative pressure inlet port (A). (2)In status (1) above, adjust screw (C) so that the control lever (B) position is a [ie, the gap between the control lever and the idle switch (E) is (L2)]. Fix by tightening the nut (D). TT
----------
L1=34.1+-3.5mm L2=4.0+-0.5mm a=7deg P1=-66.6kPa P2=-500mmHg T=6~9Nm(0.6~0.9kgfm)
----------
L2=4.0+-0.5mm a=7deg Alpha=12.5deg




Have questions with 104740-0942?





Group cross 104740-0942 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mazda 

104740-0942  

104740-0943 
 
WL8113800A 
INJECTION-PUMP ASSEMBLY
WL-NA
 
 
INJECTION-PUMP ASSEMBLY
9 460 613 324 
 
INJECTION-PUMP ASSEMBLY

Mazda 

9 460 613 519 
WL8113800B 
INJECTION-PUMP ASSEMBLY
WL-NA
9 460 614 207 
WL8113800C 
INJECTION-PUMP ASSEMBLY
WL-NA
Back to top