Rating:
Information injection-pump assembly
ZEXEL
104740-0220
1047400220
MAZDA
483613800
483613800
Cross reference number
ZEXEL
104740-0220
1047400220
MAZDA
483613800
483613800
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
(Note)
For Japan: year/month/day (change sequence) 1988/08/05 (1)
For Japan: year/month/day (change sequence) 1988/08/05 (1)
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
51.4
50.9
51.9
Difference in delivery
mm3/st.
3
Basic
*
Injection timing adjustment_02
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
17.5
14.5
20.5
Injection timing adjustment_03
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
51.4
50.4
52.4
Injection timing adjustment_04
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
48
46
50
Injection timing adjustment_05
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
50.2
49.7
50.7
Difference in delivery
mm3/st.
3
Basic
*
Remarks
For Japan
For Japan
Injection timing adjustment_06
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
17.1
14.1
20.1
Remarks
For Japan
For Japan
Injection timing adjustment_07
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
50.2
49.2
51.2
Remarks
For Japan
For Japan
Injection timing adjustment_08
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
46.9
44.9
48.9
Remarks
For Japan
For Japan
Injection quantity adjustment
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
17.5
15.5
19.5
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
1040
1040
1040
Average injection quantity
mm3/st.
6.2
Injection quantity adjustment_03
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
17.1
14.1
20.1
Basic
*
Remarks
For Japan
For Japan
Injection quantity adjustment_04
Pump speed
r/min
1040
1040
1040
Average injection quantity
mm3/st.
6
Remarks
For Japan
For Japan
Governor adjustment
Pump speed
r/min
475
475
475
Average injection quantity
mm3/st.
13.1
11.1
15.1
Difference in delivery
mm3/st.
2.5
Basic
*
Governor adjustment_02
Pump speed
r/min
475
475
475
Average injection quantity
mm3/st.
13.1
11.1
15.1
Governor adjustment_03
Pump speed
r/min
475
475
475
Average injection quantity
mm3/st.
12.8
10.8
14.8
Difference in delivery
mm3/st.
2.5
Basic
*
Remarks
For Japan
For Japan
Governor adjustment_04
Pump speed
r/min
475
475
475
Average injection quantity
mm3/st.
12.8
10.8
14.8
Remarks
For Japan
For Japan
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
80.4
Basic
*
Timer adjustment_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
78
Basic
*
Remarks
For Japan
For Japan
Speed control lever angle
Pump speed
r/min
475
475
475
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
Speed control lever angle_02
Pump speed
r/min
475
475
475
Average injection quantity
mm3/st.
0
0
0
Remarks
For Japan: Magnet OFF
For Japan: Magnet OFF
0000000901
Pump speed
r/min
500
500
500
Overflow quantity
cm3/min
300
168
432
_02
Pump speed
r/min
500
500
500
Overflow quantity
cm3/min
300
168
432
Remarks
For Japan
For Japan
Stop lever angle
Pump speed
r/min
900
900
900
Pressure
kPa
402
373
431
Pressure
kgf/cm2
4.1
3.8
4.4
Basic
*
Stop lever angle_02
Pump speed
r/min
500
500
500
Pressure
kPa
264.5
235
294
Pressure
kgf/cm2
2.7
2.4
3
Stop lever angle_03
Pump speed
r/min
900
900
900
Pressure
kPa
402
373
431
Pressure
kgf/cm2
4.1
3.8
4.4
Stop lever angle_04
Pump speed
r/min
900
900
900
Pressure
kPa
392.5
363
422
Pressure
kgf/cm2
4
3.7
4.3
Basic
*
Remarks
For Japan
For Japan
Stop lever angle_05
Pump speed
r/min
500
500
500
Pressure
kPa
255
226
284
Pressure
kgf/cm2
2.6
2.3
2.9
Remarks
For Japan
For Japan
Stop lever angle_06
Pump speed
r/min
900
900
900
Pressure
kPa
392.5
363
422
Pressure
kgf/cm2
4
3.7
4.3
Remarks
For Japan
For Japan
0000001101
Pump speed
r/min
900
900
900
Timer stroke
mm
1.6
1.4
1.8
Basic
*
_02
Pump speed
r/min
900
900
900
Timer stroke
mm
1.6
1.3
1.9
_03
Pump speed
r/min
900
900
900
Timer stroke
mm
1.6
1.4
1.8
Basic
*
Remarks
For Japan
For Japan
_04
Pump speed
r/min
900
900
900
Timer stroke
mm
1.6
1.3
1.9
Remarks
For Japan
For Japan
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.8
1.7
1.9
Pre-stroke
mm
0.2
0.18
0.22
Control lever angle alpha
deg.
20
16
24
Control lever angle beta
deg.
41
36
46