Rating:
Information injection-pump assembly
ZEXEL
104740-0190
1047400190
MAZDA
483313800
483313800
Cross reference number
ZEXEL
104740-0190
1047400190
MAZDA
483313800
483313800
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
(Note)
For Japan: year/month/day (change sequence) 1988/08/05 (1)
For Japan: year/month/day (change sequence) 1988/08/05 (1)
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105000-2010
Bosch type code
NP-DN12SD12TT
Nozzle holder
105780-2080
Opening pressure
MPa
14.7
14.7
15.19
Opening pressure
kgf/cm2
150
150
155
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-840
Inside diameter - outside diameter - length (mm) mm 2-6-840
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
55
54.5
55.5
Difference in delivery
mm3/st.
3.5
Basic
*
Injection timing adjustment_02
Pump speed
r/min
1680
1680
1680
Average injection quantity
mm3/st.
12.9
9.9
15.9
Injection timing adjustment_03
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
53.6
51.6
55.6
Injection timing adjustment_04
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
55
54
56
Injection timing adjustment_05
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
48.8
46.8
50.8
Injection timing adjustment_06
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
53.6
53.1
54.1
Difference in delivery
mm3/st.
3.5
Basic
*
Remarks
For Japan
For Japan
Injection timing adjustment_07
Pump speed
r/min
1680
1680
1680
Average injection quantity
mm3/st.
12.6
9.6
15.6
Remarks
For Japan
For Japan
Injection timing adjustment_08
Pump speed
r/min
1500
1500
1500
Average injection quantity
mm3/st.
52.3
50.3
54.3
Remarks
For Japan
For Japan
Injection timing adjustment_09
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
53.6
52.6
54.6
Remarks
For Japan
For Japan
Injection timing adjustment_10
Pump speed
r/min
500
500
500
Average injection quantity
mm3/st.
47.6
45.6
49.6
Remarks
For Japan
For Japan
Injection quantity adjustment
Pump speed
r/min
1680
1680
1680
Average injection quantity
mm3/st.
12.9
10.9
14.9
Basic
*
Injection quantity adjustment_02
Pump speed
r/min
1780
1780
1780
Average injection quantity
mm3/st.
4.1
Injection quantity adjustment_03
Pump speed
r/min
1680
1680
1680
Average injection quantity
mm3/st.
12.6
9.6
15.6
Basic
*
Remarks
For Japan
For Japan
Injection quantity adjustment_04
Pump speed
r/min
1780
1780
1780
Average injection quantity
mm3/st.
4
Remarks
For Japan
For Japan
Governor adjustment
Pump speed
r/min
315
315
315
Average injection quantity
mm3/st.
13.1
11.1
15.1
Difference in delivery
mm3/st.
2.5
Basic
*
Governor adjustment_02
Pump speed
r/min
315
315
315
Average injection quantity
mm3/st.
13.1
11.1
15.1
Governor adjustment_03
Pump speed
r/min
620
Average injection quantity
mm3/st.
0
0
0
Governor adjustment_04
Pump speed
r/min
315
315
315
Average injection quantity
mm3/st.
12.8
10.8
14.8
Difference in delivery
mm3/st.
2.5
Basic
*
Remarks
For Japan
For Japan
Governor adjustment_05
Pump speed
r/min
315
315
315
Average injection quantity
mm3/st.
12.8
10.8
14.8
Remarks
For Japan
For Japan
Governor adjustment_06
Pump speed
r/min
620
Average injection quantity
mm3/st.
0
0
0
Remarks
For Japan
For Japan
Timer adjustment
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
80.4
80.4
Basic
*
Timer adjustment_02
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
78
78
Basic
*
Remarks
For Japan
For Japan
Speed control lever angle
Pump speed
r/min
315
315
315
Average injection quantity
mm3/st.
0
0
0
Remarks
Magnet OFF
Magnet OFF
Speed control lever angle_02
Pump speed
r/min
315
315
315
Average injection quantity
mm3/st.
0
0
0
Remarks
For Japan: Magnet OFF
For Japan: Magnet OFF
0000000901
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
450
318
582
_02
Pump speed
r/min
1000
1000
1000
Overflow quantity
cm3/min
450
318
582
Remarks
For Japan
For Japan
Stop lever angle
Pump speed
r/min
1000
1000
1000
Pressure
kPa
431.5
402
461
Pressure
kgf/cm2
4.4
4.1
4.7
Basic
*
Stop lever angle_02
Pump speed
r/min
500
500
500
Pressure
kPa
264.5
235
294
Pressure
kgf/cm2
2.7
2.4
3
Stop lever angle_03
Pump speed
r/min
1000
1000
1000
Pressure
kPa
431.5
402
461
Pressure
kgf/cm2
4.4
4.1
4.7
Stop lever angle_04
Pump speed
r/min
1500
1500
1500
Pressure
kPa
598.5
569
628
Pressure
kgf/cm2
6.1
5.8
6.4
Stop lever angle_05
Pump speed
r/min
1000
1000
1000
Pressure
kPa
421.5
392
451
Pressure
kgf/cm2
4.3
4
4.6
Basic
*
Remarks
For Japan
For Japan
Stop lever angle_06
Pump speed
r/min
500
500
500
Pressure
kPa
255
226
284
Pressure
kgf/cm2
2.6
2.3
2.9
Remarks
For Japan
For Japan
Stop lever angle_07
Pump speed
r/min
1000
1000
1000
Pressure
kPa
421.5
392
451
Pressure
kgf/cm2
4.3
4
4.6
Remarks
For Japan
For Japan
Stop lever angle_08
Pump speed
r/min
1500
1500
1500
Pressure
kPa
588.5
559
618
Pressure
kgf/cm2
6
5.7
6.3
Remarks
For Japan
For Japan
0000001101
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
2.3
2.1
2.5
Basic
*
_02
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
2.3
2
2.6
_03
Pump speed
r/min
1500
1500
1500
Timer stroke
mm
5.3
4.7
5.9
_04
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
2.2
2
2.4
Basic
*
Remarks
For Japan
For Japan
_05
Pump speed
r/min
1000
1000
1000
Timer stroke
mm
2.2
1.9
2.5
Remarks
For Japan
For Japan
_06
Pump speed
r/min
1500
1500
1500
Timer stroke
mm
5.2
4.6
5.8
Remarks
For Japan
For Japan
0000001201
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
Timing setting
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
MS dimension
mm
1.8
1.7
1.9
Pre-stroke
mm
0.2
0.18
0.22
Control lever angle alpha
deg.
24
19
29
Control lever angle beta
deg.
42
37
47