Rating:
Information injection-pump assembly
BOSCH
9 460 614 814
9460614814
ZEXEL
104700-3000
1047003000
Cross reference number
BOSCH
9 460 614 814
9460614814
ZEXEL
104700-3000
1047003000
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113orSAEJ967d
1404 Test oil ISO4113orSAEJ967d
Test oil temperature
degC
45
45
50
Nozzle
105780-0060
Bosch type code
NP-DN0SD1510
Nozzle holder
105780-2150
Opening pressure
MPa
13
13
13.3
Opening pressure
kgf/cm2
133
133
136
Injection pipe
157805-7320
Injection pipe
Inside diameter - outside diameter - length (mm) mm 2-6-450
Inside diameter - outside diameter - length (mm) mm 2-6-450
Joint assembly
157641-4720
Tube assembly
157641-4020
Transfer pump pressure
kPa
20
20
20
Transfer pump pressure
kgf/cm2
0.2
0.2
0.2
Direction of rotation (viewed from drive side)
Right R
Right R
Manual controller assembly
105782-8280
Manual controller
105782-8270
Wire harness
407980-2390
Intermediate harness
407980-2400
Governor adjustment
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Pump chamber pressure
kPa
588.5
559
618
Pump chamber pressure
kgf/cm2
6
5.7
6.3
Basic
*
Governor adjustment_02
Pump speed
r/min
100
100
100
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Pump chamber pressure
kPa
294
294
Pump chamber pressure
kgf/cm2
3
3
Governor adjustment_03
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Pump chamber pressure
kPa
588
549
627
Pump chamber pressure
kgf/cm2
6
5.6
6.4
Governor adjustment_04
Pump speed
r/min
2100
2100
2100
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Pump chamber pressure
kPa
745
696
794
Pump chamber pressure
kgf/cm2
7.6
7.1
8.1
Boost compensator adjustment
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Timer stroke
mm
9.9
9.7
10.1
Basic
*
Boost compensator adjustment_02
Pump speed
r/min
100
100
100
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Timer stroke
mm
3.8
1.7
5.9
Boost compensator adjustment_03
Pump speed
r/min
350
350
350
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Timer stroke
mm
8
5.9
10.1
Boost compensator adjustment_04
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Timer stroke
mm
9.9
9.6
10.2
Boost compensator adjustment_05
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
80
80
80
U alpha soll
V
2.86
2.86
2.86
Timer stroke
mm
6.3
4.8
7.8
Boost compensator adjustment_06
Pump speed
r/min
2100
2100
2100
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Timer stroke
mm
11.35
10.9
11.8
Boost compensator adjustment_07
Pump speed
r/min
2100
2100
2100
TCV duty (%) F TCV 60Hz
%
0
0
0
U alpha soll
V
2.86
2.86
2.86
Timer stroke
mm
0
0
0
Timer adjustment
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
0
0
0
U alpha soll
V
2.86
2.86
2.86
Vtps
V
0.77
0.35
1.19
Basic
*
Timer adjustment_02
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
0
0
0
U alpha soll
V
2.86
2.86
2.86
Vtps
V
0.77
0.35
1.19
Timer adjustment_03
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Vtps
V
4.252
3.848
4.656
Speed control lever angle
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Overflow quantity
cm3/min
560
430
690
0000000901
Pump speed
r/min
1250
1250
1250
U alpha soll + dU alpha soll
V
2.86
2.86
2.86
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
78.4
77.9
78.9
Difference in delivery
mm3/st.
4.5
Basic
*
_02
Pump speed
r/min
375
375
375
U alpha soll + dU alpha soll
V
1.99
1.99
1.99
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
14.6
11.6
17.6
Difference in delivery
mm3/st.
2
Basic
*
Remarks
Confirmation of difference in delivery
Confirmation of difference in delivery
_03
Pump speed
r/min
100
100
100
U alpha soll + dU alpha soll
V
2.99
2.99
2.99
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
56.5
46.5
66.5
_04
Pump speed
r/min
375
375
375
U alpha soll + dU alpha soll
V
1.99
1.99
1.99
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
14.6
11.6
17.6
_05
Pump speed
r/min
400
400
400
U alpha soll + dU alpha soll
V
2.63
2.63
2.63
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
45.8
43.3
48.3
_06
Pump speed
r/min
500
500
500
U alpha soll + dU alpha soll
V
2.56
2.56
2.56
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
47.2
44.7
49.7
_07
Pump speed
r/min
600
600
600
U alpha soll + dU alpha soll
V
2.54
2.54
2.54
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
48.8
46.3
51.3
_08
Pump speed
r/min
750
750
750
U alpha soll + dU alpha soll
V
2.8
2.8
2.8
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
67.9
65.4
70.4
_09
Pump speed
r/min
1250
1250
1250
U alpha soll + dU alpha soll
V
2.86
2.86
2.86
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
78.4
77.4
79.4
_10
Pump speed
r/min
1500
1500
1500
U alpha soll + dU alpha soll
V
2.77
2.77
2.77
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
73.8
71.3
76.3
_11
Pump speed
r/min
2100
2100
2100
U alpha soll + dU alpha soll
V
2.64
2.64
2.64
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
62.8
60.3
65.3
_12
Pump speed
r/min
2650
2650
2650
U alpha soll + dU alpha soll
V
1.93
1.93
1.93
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
mm3/st.
23
20.5
25.5
Stop lever angle
Pump speed
r/min
2100
2100
2100
U alpha soll + dU alpha soll
V
2.64
2.64
2.64
TCV duty (%) F TCV 60Hz
%
100
100
100
Average injection quantity
cm3/min
0
0
0
0000001101
Pump speed
r/min
200
200
200
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Speed output
N=Measure the actual speed. r/min N+-8
N=Measure the actual speed. r/min N+-8
0000001201
Pump speed
r/min
1000
1000
1000
TCV duty (%) F TCV 60Hz
%
100
100
100
U alpha soll
V
2.86
2.86
2.86
Temperature output
Measure T = actual output temperature degC T+-5
Measure T = actual output temperature degC T+-5
0000001301
Max. applied voltage
V
8
8
8
Test voltage
V
13
12
14
0000001401
K dimension
mm
3.3
3.2
3.4
KF dimension
mm
5.8
5.7
5.9
Pre-stroke
mm
0.1
0.08
0.12
Test data Ex:
Injection timing adjustment Comp. resistor/voltage
Compensation resistance/compensation voltage comparison
A = Compensation resistor number
B= Compensation resistance
C = Compensation voltage delta U alpha soll
----------
----------
----------
----------
0000001601 HARNESS & CONNECTOR
TCV connector assembly specification
(1)Ensure the GE harness is not twisted at section A.
(2)Refer to the figure for the direction of connector clip B.
(3)Route the TCV harness in the direction indicated by the arrows in the figure and install the connector C.
----------
----------
----------
----------
0000001701 HARNESS & CONNECTOR
Connector and binder assembly specification
(1)For A's connector, adjust the position of the protective tube to L1 and install.
(2)Assemble the connectors and clips in the order A, B, C, D, E, F and G.
(3)Fix the GE cable and the FCV cable using the binder (C).
(4)Clip the Q adjustment, the P/U and the TPS harnesses using clip G.
A:G.E. Connector
B:F.C.V. terminal
C:Clip (be careful of installation direction)
D:Q adjustment connector
E:P/U Connector
F:T.P.S. Connector
G:Binder
I:Protective tube
----------
----------
L1=10+-5mm
----------
----------