Rating:
Information injection-pump assembly
ZEXEL
103682-0500
1036820500
Service parts 103682-0500 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
10.
NOZZLE AND HOLDER ASSY
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
13.
NOZZLE-HOLDER
14.
NOZZLE
15.
NOZZLE SET
Cross reference number
ZEXEL
103682-0500
1036820500
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8130
Bosch type code
EFEP215A
Nozzle
105780-0050
Bosch type code
DN6TD119NP1T
Nozzle holder
105780-2090
Bosch type code
EFEP215
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-4-1500
Outer diameter - inner diameter - length (mm) mm 8-4-1500
Overflow valve
131424-1420
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
4.5
4.45
4.55
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.5 60.5
Cal 1-4 deg. 60 59.5 60.5
Difference between angles 2
Cyl.1-2 deg. 120 119.5 120.5
Cyl.1-2 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cal 1-3 deg. 240 239.5 240.5
Cal 1-3 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-5 deg. 300 299.5 300.5
Cal 1-5 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
19.6
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
777
762
792
Max. variation between cylinders
%
0
-3
3
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
7
Pump speed
r/min
640
630
640
Average injection quantity
mm3/st.
90.5
85.2
95.8
Max. variation between cylinders
%
0
-10
10
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
20.7
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
841
821
861
Fixing the rack
*
Injection quantity adjustment_04
Adjusting point
D
Rack position
9.3+-0.5
Pump speed
r/min
250
250
250
Average injection quantity
mm3/st.
100
90
110
Fixing the rack
*
Injection quantity adjustment_05
Adjusting point
E
Rack position
21.7+0.5
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
770
770
830
Fixing the lever
*
Rack limit
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Delivered with idle spring not operating.
(3)RACK LIMIT: RAL
(4)Idle sub spring setting: L1.
----------
K=25 RAL=21.7+0.5mm L1=7-0.5mm
----------
----------
K=25 RAL=21.7+0.5mm L1=7-0.5mm
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Actual measurement
(2)Actual measurement
(3)Stopper bolt setting
----------
----------
----------
----------
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=35deg+-5deg b=45deg+-5deg
----------
----------
a=35deg+-5deg b=45deg+-5deg
Timing setting
(1)Pump vertical direction
(2)Position of middle of pump side coupling's elongated hole at No 1 cylinder's beginning of injection
(3)-
(4)-
----------
----------
a=(50deg)
----------
----------
a=(50deg)