Rating:
Information injection-pump assembly
ZEXEL
103662-3100
1036623100
KOMATSU
6162731570
6162731570
Service parts 103662-3100 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
6162-13-3902
12.
Open Pre:MPa(Kqf/cm2)
29.4{300}
15.
NOZZLE SET
Cross reference number
ZEXEL
103662-3100
1036623100
KOMATSU
6162731570
6162731570
Zexel num
Bosch num
Firm num
Name
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8130
Bosch type code
EFEP215A
Nozzle
105780-0050
Bosch type code
DN6TD119NP1T
Nozzle holder
105780-2090
Bosch type code
EFEP215
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 8-4-1500
Outer diameter - inner diameter - length (mm) mm 8-4-1500
Overflow valve
133424-0420
Overflow valve opening pressure
kPa
206
172
240
Overflow valve opening pressure
kgf/cm2
2.1
1.75
2.45
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3.8
3.75
3.85
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
16.6
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
473.5
468.5
478.5
Max. variation between cylinders
%
0
-4
4
Basic
*
Fixing the lever
*
Boost pressure
kPa
50.7
50.7
Boost pressure
mmHg
380
380
Injection quantity adjustment_02
Adjusting point
B
Rack position
9.1+-0.5
Pump speed
r/min
350
350
350
Average injection quantity
mm3/st.
48
44
52
Max. variation between cylinders
%
0
-14
14
Fixing the rack
*
Boost pressure
kPa
0
0
0
Boost pressure
mmHg
0
0
0
Injection quantity adjustment_03
Adjusting point
C
Rack position
18
Pump speed
r/min
700
700
700
Average injection quantity
mm3/st.
488
483
493
Fixing the lever
*
Boost pressure
kPa
50.7
50.7
Boost pressure
mmHg
380
380
Boost compensator adjustment
Pump speed
r/min
500
500
500
Rack position
14
Boost pressure
kPa
12
12
12
Boost pressure
mmHg
90
90
90
Boost compensator adjustment_02
Pump speed
r/min
500
500
500
Rack position
18
Boost pressure
kPa
41.3
38.6
44
Boost pressure
mmHg
310
290
330
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Notch: K
(2)RACK LIMIT: RAL
(3)Boost compensator stroke: BCL
(4)Rack difference between N = N1 and N = N2
----------
K=10 RAL=20+0.2mm BCL=4+-0.1mm N1=1000r/min N2=700r/min
----------
----------
K=10 RAL=20+0.2mm BCL=4+-0.1mm N1=1000r/min N2=700r/min
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Stopper bolt setting
----------
----------
a=17deg+-5deg b=38deg+-5deg
----------
----------
a=17deg+-5deg b=38deg+-5deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Use the pin at R = aa
(2)The clearance from the set screw must be bb.
(3)Set the screw at speed = cc and rack position = dd.
----------
aa=44mm bb=2+1mm cc=100r/min dd=5mm
----------
a=20deg+-5deg b=40deg+-5deg
----------
aa=44mm bb=2+1mm cc=100r/min dd=5mm
----------
a=20deg+-5deg b=40deg+-5deg