Rating:
Information injection-pump assembly
BOSCH
9 400 615 973
9400615973
ZEXEL
101691-1861
1016911861
MITSUBISHI
ME088107
me088107
Cross reference number
BOSCH
9 400 615 973
9400615973
ZEXEL
101691-1861
1016911861
MITSUBISHI
ME088107
me088107
Zexel num
Bosch num
Firm num
Name
101691-1861
9 400 615 973
ME088107 MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D31T * K 14BE INJECTION PUMP ASSY PE6A PE
6D31T * K 14BE INJECTION PUMP ASSY PE6A PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-5620
Overflow valve opening pressure
kPa
157
123
191
Overflow valve opening pressure
kgf/cm2
1.6
1.25
1.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3.5
3.45
3.55
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
9.9
Pump speed
r/min
1250
1250
1250
Average injection quantity
mm3/st.
72.8
71.8
73.8
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
7.4+-0.5
Pump speed
r/min
375
375
375
Average injection quantity
mm3/st.
7.5
6.2
8.8
Max. variation between cylinders
%
0
-14
14
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
C
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
66
66
71
Fixing the lever
*
Rack limit
*
Timer adjustment
Pump speed
r/min
1250++
Advance angle
deg.
0
0
0
Remarks
Do not advance until starting N = 1250
Do not advance until starting N = 1250
Timer adjustment_02
Pump speed
r/min
1250
Advance angle
deg.
0.5
Timer adjustment_03
Pump speed
r/min
-
Advance angle
deg.
3
3
3
Remarks
Measure the actual speed, stop
Measure the actual speed, stop
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)Deliver without the torque control spring operating.
(3)Supplied with torque spring not set.
(4)RACK LIMIT
(5)Setting at shipping
----------
K=15
----------
----------
K=15
----------
Speed control lever angle
F:Full speed
I:Idle
(1)At shipping
(2)Stopper bolt setting
----------
----------
a=30deg+-5deg b=18deg+-5deg c=(2deg)
----------
----------
a=30deg+-5deg b=18deg+-5deg c=(2deg)
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)At shipping
----------
----------
a=38deg+-5deg b=53deg+-5deg
----------
----------
a=38deg+-5deg b=53deg+-5deg
Timing setting
(1)Pump vertical direction
(2)Position of gear mark '3' at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=16deg
----------
a=(130deg)
----------
aa=16deg
----------
a=(130deg)
Have questions with 101691-1861?
Group cross 101691-1861 ZEXEL
Mitsubishi
101691-1861
9 400 615 973
ME088107
INJECTION-PUMP ASSEMBLY
6D31T
6D31T