Rating:
Information injection-pump assembly
ZEXEL
101672-2530
1016722530
HINO
220801250A
220801250a
Cross reference number
ZEXEL
101672-2530
1016722530
HINO
220801250A
220801250a
Zexel num
Bosch num
Firm num
Name
101672-2530
220801250A HINO
INJECTION-PUMP ASSEMBLY
DS50 * K
DS50 * K
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-4-2-6-
3-5
Pre-stroke
mm
2.1
2.05
2.15
Rack position
After adjusting injection quantity. R=14.3
After adjusting injection quantity. R=14.3
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-4 deg. 60 59.5 60.5
Cal 1-4 deg. 60 59.5 60.5
Difference between angles 2
Cyl.1-2 deg. 120 119.5 120.5
Cyl.1-2 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cal 1-3 deg. 240 239.5 240.5
Cal 1-3 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-5 deg. 300 299.5 300.5
Cal 1-5 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
11.8
Pump speed
r/min
900
900
900
Average injection quantity
mm3/st.
66.9
65.3
68.5
Max. variation between cylinders
%
0
-2
2
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
B
Rack position
8+-0.5
Pump speed
r/min
225
225
225
Average injection quantity
mm3/st.
20
17.4
22.6
Max. variation between cylinders
%
0
-13
13
Fixing the rack
*
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)RACK LIMIT
(2)Set using full load set screw.
(3)With isochronous switch ON
(4)When isochronous switch OFF
----------
----------
----------
----------
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=0deg+-5deg b=33deg+-3deg
----------
----------
a=0deg+-5deg b=33deg+-3deg
Have questions with 101672-2530?
Group cross 101672-2530 ZEXEL
Hino
101672-2530
220801250A
INJECTION-PUMP ASSEMBLY
DS50
DS50