Rating:
Information injection-pump assembly
BOSCH
9 400 615 946
9400615946
ZEXEL
101671-1370
1016711370
MITSUBISHI
3006116002
3006116002
Service parts 101671-1370 INJECTION-PUMP ASSEMBLY:
1.
_
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
ME046001
12.
Open Pre:MPa(Kqf/cm2)
11.8{120}
15.
NOZZLE SET
Include in #1:
101671-1370
as INJECTION-PUMP ASSEMBLY
Cross reference number
BOSCH
9 400 615 946
9400615946
ZEXEL
101671-1370
1016711370
MITSUBISHI
3006116002
3006116002
Zexel num
Bosch num
Firm num
Name
9 400 615 946
3006116002 MITSUBISHI
INJECTION-PUMP ASSEMBLY
6DB10 K 14BE INJECTION PUMP ASSY PE6A PE
6DB10 K 14BE INJECTION PUMP ASSY PE6A PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
132424-0620
Overflow valve opening pressure
kPa
157
157
157
Overflow valve opening pressure
kgf/cm2
1.6
1.6
1.6
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
2.2
2.15
2.25
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
A
Rack position
13
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
103.5
101.5
105.5
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
D
Rack position
5.8+-0.5
Pump speed
r/min
200
200
200
Average injection quantity
mm3/st.
13
10.5
15.5
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
E
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
95
95
105
Fixing the lever
*
Rack limit
*
Timer adjustment
Pump speed
r/min
100+100
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
200
Advance angle
deg.
0
0
0.6
Timer adjustment_03
Pump speed
r/min
500
Advance angle
deg.
1.6
1.1
2.1
Timer adjustment_04
Pump speed
r/min
800
Advance angle
deg.
3.2
2.6
3.8
Timer adjustment_05
Pump speed
r/min
1100
Advance angle
deg.
5
4.5
5.5
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Lever ratio: RT
(2)Target shim dimension: TH
(3)Tolerance for racks not indicated: +-0.05mm.
(4)RACK LIMIT
(5)Supplied with damper spring not set.
----------
RT=1 TH=(3.5)mm
----------
----------
RT=1 TH=(3.5)mm
----------
Speed control lever angle
F:Full speed
----------
----------
a=(10deg)+-5deg
----------
----------
a=(10deg)+-5deg
0000000901
F:Full load
I:Idle
S:Stop
----------
----------
a=46.5deg+-3deg b=(7.5deg) c=34.5+5deg
----------
----------
a=46.5deg+-3deg b=(7.5deg) c=34.5+5deg