101607-1962 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016071962


101607-1962 INJECTION-PUMP ASSEMBLY
Rating:
10
Buy INJECTION-PUMP ASSEMBLY 101607-1962 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101607-1962 1016071962

Cross reference number

ZEXEL 101607-1962 1016071962


Zexel num
Bosch num
Firm num
Name
101607-1962 
 
   
INJECTION-PUMP ASSEMBLY

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8420
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.2 3.15 3.25
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   85.1 82.5 87.7
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   9.5+-0.5
Pump speed r/min   800 800 800
Each cylinder's injection qty mm3/st.   10.8 9.2 12.4
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   85.1 84.1 86.1
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.85
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   99.9 95.9 103.9
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   91 81 101
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1100
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   1300
Advance angle deg.   2.5 2.5 3.5
Timer adjustment_03
Pump speed r/min   1450
Advance angle deg.   6 5.5 6.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101607-1962
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=G43
----------

Speed control lever angle

Test data 101607-1962
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=18.5deg+-5deg b=(42deg)+-3deg

Stop lever angle

Test data 101607-1962
N:Engine manufacturer's normal use S:Stop the pump. (1)Set the stopper bolt at speed = aa and rack position = bb and confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed = cc and rack position = dd. (3)Rack position = approximately ee. (4)Free (at delivery)
----------
aa=1450r/min bb=7.2-0.5mm cc=275r/min dd=(8.8)mm ee=15mm
----------
a=36.5deg+-5deg b=(25deg) c=13deg+-5deg

0000001501 LEVER

Test data 101607-1962
(A) Idle (B) Full speed (C) Base lever (D) Accelerator lever (E) Accelerator lever delivery position 1. Measure speed lever angle (1)Measure the angle when the accelerator lever (D) contacted the base lever (C) at a.
----------

----------
b=(42deg)+-3deg c=18.5deg+-5deg

Timing setting

Test data 101607-1962
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=10deg
----------
a=(2deg)




Have questions with 101607-1962?





Group cross 101607-1962 ZEXEL

 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
101607-1962  
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 657 
ME076871 
INJECTION-PUMP ASSEMBLY
6D17
Back to top