101607-1360 ZEXEL 9 400 615 611 BOSCH INJECTION-PUMP ASSEMBLY 9400615611 1016071360 me076686


101607-1360 INJECTION-PUMP ASSEMBLY
Rating:
16
Buy INJECTION-PUMP ASSEMBLY 101607-1360 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 615 611 9400615611
ZEXEL 101607-1360 1016071360
MITSUBISHI ME076686 me076686

Service parts 101607-1360 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-9690
3. GOVERNOR 105931-7701
4. SUPPLY PUMP 105210-4700
5. AUTOM. ADVANCE MECHANIS 105643-0180
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105100-6780
11. Nozzle and Holder ME076000
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105031-3900
14. NOZZLE 105015-6440
15. NOZZLE SET

Include in #1:

101607-1360 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 615 611 9400615611
ZEXEL 101607-1360 1016071360
MITSUBISHI ME076686 me076686


Zexel num
Bosch num
Firm num
Name
101607-1360 
9 400 615 611 
ME076686  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D16 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.3 3.25 3.35
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.4
Pump speed r/min   700 700 700
Each cylinder's injection qty mm3/st.   54.5 52.9 56.1
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   D
Rack position   8.7+-0.5
Pump speed r/min   500 500 500
Each cylinder's injection qty mm3/st.   7.6 6.5 8.7
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.4)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   54.5 53.5 55.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.4
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   79.8 75.8 83.8
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1(11.4)
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   48.5 44.5 52.5
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   14.3+-0. 5
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   73 63 83
Fixing the lever   *
Rack limit   *
Injection quantity adjustment_07
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   8.7 7.4 10
Fixing the rack   *
Remarks
(check)
 
Timer adjustment
Pump speed r/min   900--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   850
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1200
Advance angle deg.   2.7 2.2 3.2
Timer adjustment_04
Pump speed r/min   1500
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101607-1360
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=D53
----------

Speed control lever angle

Test data 101607-1360
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18.5deg+-5deg b=41deg+-3deg

Stop lever angle

Test data 101607-1360
N:Engine manufacturer's normal use S:Stop the pump. (1)At the rated pump speed and rack position aa, set the stopper bolt. (Confirm that there is no injection.) (2)After setting the stopper bolt, confirm non-injection at speed = bb. Rack position = cc (non-injection rack position). (3)Rack position = approximately dd (4)Free (at shipping)
----------
aa=6.7-0.5mm bb=275r/min cc=(8.3)mm dd=17.4mm
----------
a=38.5deg+-5deg b=(27deg) c=17deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400r/min Ra=9.2+-0.1mm
----------

0000001601 LEVER

Test data 101607-1360
(A) Idle (B) Full speed (C) Base lever (D) Accelerator lever (E) Accelerator lever delivery position 1. Measure speed lever angle (1)Measure the angle when the accelerator lever (D) contacted the base lever (C) at a.
----------

----------
b=41deg+-3deg c=18.5deg+-5deg

0000001701 ACS

Test data 101607-1360
(A) Housing (B) Snap ring (C) adjusting screw (D) Set screw (E): Push rod (F) Spacer 1. Adjustment of the aneroid compensator (1)Adjust with the (D) set screw so that the clearance between the (A) housing and (B) snap ring is L1. (2)Select the push rod (E) so that the distance from the end surface of the (F) spacer becomes L2. (3)Turn adjusting screw (C) to adjust the start of aneroid compensator operation. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Turn adjusting screw (C) to obtain the performance shown in the graph above. (3)After final adjustment, confirm that the gap between housing (A) and snapring (B) is L3.
----------
N1=1450r/min L1=1.4~1.7mm L2=0.5+-0.5mm L3=(0.1~0.5)mm
----------
Ra=R1+0.4mm Rb=R1-0.2+-0.2mm Rc=R1-0.8+-0.1mm Pa=94.6+4kPa(710+30mmHg) Pb=79.4kPa(596mmHg) Pc=61.6kPa(462mmHg) Q1=(79.8)+-2cm3/1000st Q2=- Q3=(52)+-2cm3/1000st

Timing setting

Test data 101607-1360
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=16deg
----------
a=(1deg)




Have questions with 101607-1360?





Group cross 101607-1360 ZEXEL

F 01G 09U 057 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 607 
ME076670 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 608 
ME047887 
INJECTION-PUMP ASSEMBLY
6D14T
F 019 Z10 835 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

 
ME047808 
INJECTION-PUMP ASSEMBLY
6D16T
F 01G 09U 058 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 609 
ME076683 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 610 
ME076684 
INJECTION-PUMP ASSEMBLY
6D16
F 01G 09U 059 
ME076685 
INJECTION-PUMP ASSEMBLY
6D16
101607-1360  
9 400 615 611 
ME076686 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 612 
ME076687 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 613 
ME076678 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 614 
ME076679 
INJECTION-PUMP ASSEMBLY
6D14
Back to top