101606-6821 ZEXEL F 01G 09U 04R BOSCH INJECTION-PUMP ASSEMBLY f01g09u04r 1016066821 me076580


101606-6821 INJECTION-PUMP ASSEMBLY
Rating:
12
Buy INJECTION-PUMP ASSEMBLY 101606-6821 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 01G 09U 04R f01g09u04r
ZEXEL 101606-6821 1016066821
MITSUBISHI ME076580 me076580

Include in #1:

Cross reference number

BOSCH F 01G 09U 04R f01g09u04r
ZEXEL 101606-6821 1016066821
MITSUBISHI ME076580 me076580


Zexel num
Bosch num
Firm num
Name
101606-6821 
101607-1100 
F 01G 09U 04R 
ME076580  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D16 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.2 4.15 4.25
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.3
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   74.5 72.3 76.7
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   8 6.8 9.2
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.3)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   74.5 73.5 75.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.1
Pump speed r/min   1400 1400 1400
Average injection quantity mm3/st.   83.5 79.5 87.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.4
Pump speed r/min   500 500 500
Average injection quantity mm3/st.   69 65 73
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   146 136 156
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1150
Advance angle deg.   0.5
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.9 0.4 1.4
Timer adjustment_03
Pump speed r/min   1380
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101606-6821
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=E45
----------

Speed control lever angle

Test data 101606-6821
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18.5deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101606-6821
N:Engine manufacturer's normal use S:Stop the pump. (1)Set the stopper bolt at pump speed = aa and rack position = bb (non-injection rack position). Confirm non-injection. (2)After setting the stopper bolt, confirm non-injection at speed cc. Rack position = dd (non-injection rack position). (3)Rack position = approximately ee. (4)Free (at shipping)
----------
aa=1400r/min bb=6.5-0.5mm cc=275r/min dd=(8.5)-0.5mm ee=15mm
----------
a=38.5deg+-5deg b=(27deg) c=15.5deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400r/min Ra=9.2+-0.1mm
----------

Timing setting

Test data 101606-6821
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=11deg
----------
a=(1deg)




Have questions with 101606-6821?





Group cross 101606-6821 ZEXEL

Mitsubishi 

 
ME076552 
INJECTION-PUMP ASSEMBLY
6D16
F 01G 09U 04P 
ME076578 
INJECTION-PUMP ASSEMBLY
6D16
101606-6821  

101607-1100 
F 01G 09U 04R 
ME076580 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 538 
ME076568 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 539 
ME076569 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 540 
ME076570 
INJECTION-PUMP ASSEMBLY
6D14
9 400 615 541 
ME086598 
INJECTION-PUMP ASSEMBLY
6D31
9 400 615 542 
ME047582 
INJECTION-PUMP ASSEMBLY
6D14T
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 613 374 
ME086583 
INJECTION-PUMP ASSEMBLY
6D31T
9 400 615 543 
ME056854 
INJECTION-PUMP ASSEMBLY
6D22
Back to top