101606-6002 ZEXEL 9 400 615 481 BOSCH INJECTION-PUMP ASSEMBLY 9400615481 1016066002 me076282


101606-6002 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 101606-6002 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 615 481 9400615481
ZEXEL 101606-6002 1016066002
MITSUBISHI ME076282 me076282

Include in #2:

Cross reference number

BOSCH 9 400 615 481 9400615481
ZEXEL 101606-6002 1016066002
MITSUBISHI ME076282 me076282


Zexel num
Bosch num
Firm num
Name
101606-6002 
9 400 615 481 
ME076282  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D14T K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.3 3.25 3.35
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.5
Pump speed r/min   800 800 800
Each cylinder's injection qty mm3/st.   87.3 84.7 89.9
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   8 6.8 9.2
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.5)
Pump speed r/min   800 800 800
Average injection quantity mm3/st.   87.3 86.3 88.3
Basic   *
Fixing the lever   *
Boost pressure kPa   36.7 36.7
Boost pressure mmHg   275 275
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.75
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   85.3 81.3 89.3
Fixing the lever   *
Boost pressure kPa   36.7 36.7
Boost pressure mmHg   275 275
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1+0.2
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   86 82 90
Fixing the lever   *
Boost pressure kPa   36.7 36.7
Boost pressure mmHg   275 275
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   99 79 119
Fixing the lever   *
Rack limit   *
Boost compensator adjustment
Pump speed r/min   300 300 300
Rack position   R2-0.8
Boost pressure kPa   10 10 10
Boost pressure mmHg   75 75 75
Boost compensator adjustment_02
Pump speed r/min   300 300 300
Rack position   R2-0.6
Boost pressure kPa   13.3 12 14.6
Boost pressure mmHg   100 90 110
Boost compensator adjustment_03
Pump speed r/min   300 300 300
Rack position   R2(R1+0. 5)
Boost pressure kPa   23.3 23.3 23.3
Boost pressure mmHg   175 175 175

Test data Ex:

Governor adjustment

Test data 101606-6002
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT (4)Boost compensator stroke: BCL
----------
T1=D17 BCL=0.8+-0.1mm
----------

Timer adjustment

Test data 101606-6002
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1.5+-0.2mm N2=800r/min C3=(8)deg t1=2--sec. t2=2--sec.
----------
N1=1400r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=0.5--deg C2=8+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 101606-6002
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18.5deg+-5deg b=39deg+-3deg

Stop lever angle

Test data 101606-6002
N:Pump normal S:Stop the pump. (1)Set the stopper bolt at speed = rated point and rack position = aa (non-injection rack position). Confirm non-injection. (2)After setting the stopper bolt , confirm non-injection at pump speed bb. Rack position = cc (non-injection rack position).
----------
aa=6.5-0.5mm bb=275r/min cc=(8)mm
----------
a=11.5deg+-5deg b=27deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400r/min Ra=9.2+-0.1mm
----------

0000001601 RACK SENSOR

Test data 101606-6002
R:Rack position (mm) V:Voltage (V) After installing the rack sensor, confirm the output value (VR).
----------
N1=- Ra=R1(12.5)mm VR=1.99+-0.01V
----------

Timing setting

Test data 101606-6002
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=11deg
----------
a=(1deg)




Have questions with 101606-6002?





Group cross 101606-6002 ZEXEL

Mitsubishi 

101606-6002  
9 400 615 481 
ME076282 
INJECTION-PUMP ASSEMBLY
6D14T
9 400 611 998 
ME070914 
INJECTION-PUMP ASSEMBLY
6D14T
 
ME444573 
INJECTION-PUMP ASSEMBLY
6D14T
F 01G 09U 04H 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 610 707 
ME070915 
INJECTION-PUMP ASSEMBLY
6D14T
9 400 615 482 
ME070916 
INJECTION-PUMP ASSEMBLY
6D14T
9 400 615 483 
ME056732 
INJECTION-PUMP ASSEMBLY
6D22
9 400 615 484 
ME076241 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 485 
ME076243 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 486 
ME076247 
INJECTION-PUMP ASSEMBLY
6D16T
 
 
INJECTION-PUMP ASSEMBLY

Mitsubishi 

9 400 615 487 
ME076290 
INJECTION-PUMP ASSEMBLY
6D16
9 400 611 750 
ME070912 
INJECTION-PUMP ASSEMBLY
6D16
 
ME444637 
INJECTION-PUMP ASSEMBLY
6D16
Back to top