Rating:
Information injection-pump assembly
BOSCH
9 400 615 462
9400615462
ZEXEL
101606-1662
1016061662
MITSUBISHI
ME076244
me076244
Include in #2:
104746-6251
as _
Cross reference number
BOSCH
9 400 615 462
9400615462
ZEXEL
101606-1662
1016061662
MITSUBISHI
ME076244
me076244
Zexel num
Bosch num
Firm num
Name
101606-1662
9 400 615 462
ME076244 MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D14T * K 14BE INJECTION PUMP ASSY PE6A PE
6D14T * K 14BE INJECTION PUMP ASSY PE6A PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-5520
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3.3
3.25
3.35
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
-
Rack position
12.5
Pump speed
r/min
800
800
800
Each cylinder's injection qty
mm3/st.
87.3
84.7
89.9
Basic
*
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_02
Adjusting point
H
Rack position
9.5+-0.5
Pump speed
r/min
275
275
275
Each cylinder's injection qty
mm3/st.
8
6.8
9.2
Fixing the rack
*
Standard for adjustment of the maximum variation between cylinders
*
Injection quantity adjustment_03
Adjusting point
A
Rack position
R1(12.5)
Pump speed
r/min
800
800
800
Average injection quantity
mm3/st.
87.3
86.3
88.3
Basic
*
Fixing the lever
*
Boost pressure
kPa
36.7
36.7
Boost pressure
mmHg
275
275
Injection quantity adjustment_04
Adjusting point
B
Rack position
R1-0.75
Pump speed
r/min
1450
1450
1450
Average injection quantity
mm3/st.
85.3
81.3
89.3
Fixing the lever
*
Boost pressure
kPa
36.7
36.7
Boost pressure
mmHg
275
275
Injection quantity adjustment_05
Adjusting point
C
Rack position
R1+0.2
Pump speed
r/min
600
600
600
Average injection quantity
mm3/st.
86
82
90
Fixing the lever
*
Boost pressure
kPa
36.7
36.7
Boost pressure
mmHg
275
275
Injection quantity adjustment_06
Adjusting point
I
Rack position
-
Pump speed
r/min
100
100
100
Average injection quantity
mm3/st.
99
79
119
Fixing the lever
*
Rack limit
*
Boost compensator adjustment
Pump speed
r/min
300
300
300
Rack position
R2-0.8
Boost pressure
kPa
10
10
10
Boost pressure
mmHg
75
75
75
Boost compensator adjustment_02
Pump speed
r/min
300
300
300
Rack position
R2-0.6
Boost pressure
kPa
13.3
12
14.6
Boost pressure
mmHg
100
90
110
Boost compensator adjustment_03
Pump speed
r/min
300
300
300
Rack position
R2(R1+0.
5)
Boost pressure
kPa
23.3
23.3
23.3
Boost pressure
mmHg
175
175
175
Timer adjustment
Pump speed
r/min
1200
Advance angle
deg.
0.5
Timer adjustment_02
Pump speed
r/min
1300
Advance angle
deg.
1.7
1.2
2.2
Timer adjustment_03
Pump speed
r/min
1400
Advance angle
deg.
3.5
3
4
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Torque cam stamping: T1
(2)Tolerance for racks not indicated: +-0.05mm.
(3)RACK LIMIT
(4)Boost compensator stroke: BCL
----------
T1=D17 BCL=0.8+-0.1mm
----------
----------
T1=D17 BCL=0.8+-0.1mm
----------
Speed control lever angle
F:Full speed
I:Idle
(1)Use the hole at R = aa
(2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=33deg+-5deg b=39deg+-3deg
----------
aa=35mm
----------
a=33deg+-5deg b=39deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
(1)Use the hole at R = aa
(2)Set the stopper bolt at speed = rated point and rack position = bb (non-injection rack position). Confirm non-injection.
(3)After setting the stopper bolt, confirm non-injection at speed cc. Rack position = dd (non-injection rack position).
----------
aa=50mm bb=6.5-0.5mm cc=275r/min dd=(8)mm
----------
a=25deg+-5deg b=27deg+-5deg
----------
aa=50mm bb=6.5-0.5mm cc=275r/min dd=(8)mm
----------
a=25deg+-5deg b=27deg+-5deg
0000001501 MICRO SWITCH
Adjustment of the micro-switch
Adjust the bolt to obtain the following lever position when the micro-switch is ON.
(1)Speed N1
(2)Rack position Ra
----------
N1=400r/min Ra=9.2+-0.1mm
----------
----------
N1=400r/min Ra=9.2+-0.1mm
----------
Timing setting
(1)Pump vertical direction
(2)Position of timer's tooth at No 1 cylinder's beginning of injection
(3)B.T.D.C.: aa
(4)-
----------
aa=12deg
----------
a=(1deg)
----------
aa=12deg
----------
a=(1deg)
Have questions with 101606-1662?
Group cross 101606-1662 ZEXEL
Mitsubishi
101606-1662
9 400 615 462
ME076244
INJECTION-PUMP ASSEMBLY
6D14T
6D14T