101606-1132 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016061132 me076012


101606-1132 INJECTION-PUMP ASSEMBLY
Rating:
9
Buy INJECTION-PUMP ASSEMBLY 101606-1132 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101606-1132 1016061132
MITSUBISHI ME076012 me076012

Cross reference number

ZEXEL 101606-1132 1016061132
MITSUBISHI ME076012 me076012


Zexel num
Bosch num
Firm num
Name
101606-1132 
 
ME076012  MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D15 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5520
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.5
Pump speed r/min   850 850 850
Each cylinder's injection qty mm3/st.   69 66.9 71.1
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.9+-0.5
Pump speed r/min   275 275 275
Each cylinder's injection qty mm3/st.   9.2 8.1 10.3
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.5)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   69 68 70
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.35
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   82.5 78.5 86.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.2
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   47.6 43.6 51.6
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   80 75 85
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1250--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1350
Advance angle deg.   2.4 1.9 2.9
Timer adjustment_04
Pump speed r/min   1500
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101606-1132
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=C92
----------

Speed control lever angle

Test data 101606-1132
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18.5deg+-5deg b=(42deg)+-3deg

Stop lever angle

Test data 101606-1132
N:Engine manufacturer's normal use S:Stop the pump. (1)Set the stopper bolt at speed = rated point and rack position = aa (non-injection rack position). Confirm non-injection. (2)After setting the stopper bolt , confirm non-injection at pump speed bb. Rack position = cc (non-injection rack position). (3)Rack position = approximately dd (4)Free (at shipping)
----------
aa=(7)mm bb=275r/min cc=(8)mm dd=17.4mm
----------
a=38.5deg+-5deg b=(27deg) c=17deg+-5deg

0000001201

Test data 101606-1132
I:Idle F:At operation, hold it in the full speed position. (1)Rack position = aa, speed = bb.
----------
aa=8.5mm bb=1490r/min
----------
a=15deg+-5deg b=(36deg)+-3deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=400+-5r/min Ra=9.7mm
----------

Timing setting

Test data 101606-1132
(1)Pump vertical direction (2)Position of timer's tooth at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=12deg
----------
a=(1deg)




Have questions with 101606-1132?





Group cross 101606-1132 ZEXEL

Mitsubishi 

9 400 615 425 
ME050825 
INJECTION-PUMP ASSEMBLY
6D22
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
9 400 615 426 
ME076010 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME076011 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
101606-1132  
 
ME076012 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME076013 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
F 01G 09U 04D 
ME076017 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
ME076018 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D15
9 400 615 427 
ME076019 
INJECTION-PUMP ASSEMBLY
6D15
 
 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 428 
ME047471 
INJECTION-PUMP ASSEMBLY
6D16
9 400 615 429 
ME047289 
INJECTION-PUMP ASSEMBLY
6D16T
Back to top