101606-0101 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016060101 8976000022


101606-0101 INJECTION-PUMP ASSEMBLY
Rating:
9
Buy INJECTION-PUMP ASSEMBLY 101606-0101 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101606-0101 1016060101
ISUZU 8976000022 8976000022

Service parts 101606-0101 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-6570
3. GOVERNOR 105932-3351
4. SUPPLY PUMP 105230-1090
5. AUTOM. ADVANCE MECHANIS 105690-0241
6. COUPLING PLATE 105661-1170
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-7743
11. Nozzle and Holder 8-94391-291-4
12. Open Pre:MPa(Kqf/cm2) 16.2{165}/19.6{200}
13. NOZZLE-HOLDER 105041-2082
14. NOZZLE
15. NOZZLE SET 105019-2190

Include in #1:

101606-0101 as INJECTION-PUMP ASSEMBLY

Include in #2:

Cross reference number

ZEXEL 101606-0101 1016060101
ISUZU 8976000022 8976000022


Zexel num
Bosch num
Firm num
Name
101606-0101 
101606-0102 
 
8976000022  ISUZU
INJECTION-PUMP ASSEMBLY
6HL1-N * K 14BF PE6AD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8260
Bosch type code   9 430 610 133
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   18
Opening pressure kgf/cm2   184
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8620
Overflow valve opening pressure kPa   206 172 240
Overflow valve opening pressure kgf/cm2   2.1 1.75 2.45
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.8 3.75 3.85
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   14.5
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   133.5 131.9 135.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   9.5+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   15.5 14.2 16.8
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(14.5)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   133.5 132.5 134.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   (R1+0.65 )+0.05-0 .15
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   127 123.8 130.2
Fixing the lever   *

Test data Ex:

Governor adjustment

Test data 101606-0101
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=N11
----------

Timer adjustment

Test data 101606-0101
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1.5+-0.2mm N2=800r/min C2=(8deg) t1=2--sec. t2=2--sec.
----------
N1=1300++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=8+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 101606-0101
F:Full speed I:Idle (1)Stopper bolt set position 'H' (2)Use the pin at R = aa (3)Viewed from feed pump side.
----------
aa=35mm
----------
a=10deg+-5deg b=40deg+-3deg

Stop lever angle

Test data 101606-0101
N:Pump normal S:Stop the pump. (1)Use the pin at R = aa
----------
aa=45mm
----------
a=12.5deg+-5deg b=40deg+-5deg

0000001501 RACK SENSOR

Test data 101606-0101
Rack sensor adjustment 1. Flange type rack sensor (rack sensor adjustment -5*20) (1)These types of rack sensors do not need adjustment. Confirm the performance with the following procedures. (2)Mount the rack sensor main body to the pump main body. (3)Fix the pump lever at full. (4)At supply voltage V1, pump speed N1 and rack position Ra, confirm that the amp's output voltage is Vist. (5)Move the pump lever two or three times. (6)Set again to full. (7)Confirm that the amplifier output voltage is Vist. (8)Fix the caution plate to the upper part of the rack sensor. (For those without the caution plate instructions, make sure the nameplate of the rack sensor carries the "Don't hold here" caution.) (9)Apply red paint to the rack sensor mounting bolts (2 places).
----------
V1=5+-0.01V N1=850r/min Ra=R1(14.5)mm Vist=3.74+-0.28V
----------

Timing setting

Test data 101606-0101
(1)Pump vertical direction (2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=6deg
----------
a=(160deg)




Have questions with 101606-0101?





Group cross 101606-0101 ZEXEL

Isuzu 

 
8976000020 
INJECTION-PUMP ASSEMBLY
6HL1-N
101606-0101  

101606-0102 
 
8976000022 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 611 603 
8976000023 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 611 707 
8976000024 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8976000030 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8976000032 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 516 
8976000033 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 708 
8976000034 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8976000040 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8976000042 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8976000043 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 615 406 
8976000044 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 613 033 
8976001800 
INJECTION-PUMP ASSEMBLY
6HH1-S
 
8976000811 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 611 748 
8976000812 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 611 517 
8976004550 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 615 407 
8976004551 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 604 
8976004560 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 387 
8976004561 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8976004570 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 612 168 
8976004571 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 613 103 
8976004572 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 518 
1156033430 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 612 169 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 612 946 
1156034151 
INJECTION-PUMP ASSEMBLY
6BG1-T
9 400 615 408 
8976004960 
INJECTION-PUMP ASSEMBLY
6HH1-S
Back to top