101606-0090 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016060090 8976000010


101606-0090 INJECTION-PUMP ASSEMBLY
Rating:
84
Buy INJECTION-PUMP ASSEMBLY 101606-0090 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101606-0090 1016060090
ISUZU 8976000010 8976000010

Cross reference number

ZEXEL 101606-0090 1016060090
ISUZU 8976000010 8976000010


Zexel num
Bosch num
Firm num
Name
101606-0090 
101606-0091 
 
8976000010  ISUZU
INJECTION-PUMP ASSEMBLY
6HL1-S * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8260
Bosch type code   9 430 610 133
Nozzle   105780-0120
Bosch type code   1 688 901 990
Nozzle holder   105780-2190
Opening pressure MPa   18
Opening pressure kgf/cm2   184
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8620
Overflow valve opening pressure kPa   206 172 240
Overflow valve opening pressure kgf/cm2   2.1 1.75 2.45
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.8 3.75 3.85
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   14.5
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   133.5 131.9 135.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   9.5+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   15.5 14.2 16.8
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(14.5)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   133.5 132.5 134.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   (R1+1.05 )+0.05-0 .15
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   133 129.8 136.2
Fixing the lever   *

Test data Ex:

Governor adjustment

Test data 101606-0090
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=N14
----------

Timer adjustment

Test data 101606-0090
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1.5+-0.2mm N2=800r/min C2=(8deg) t1=2--sec. t2=2--sec.
----------
N1=1300++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=8+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 101606-0090
F:Full speed I:Idle (1)Stopper bolt set position 'H' (2)Use the pin at R = aa (3)Viewed from feed pump side.
----------
aa=35mm
----------
a=10deg+-5deg b=41deg+-3deg

Stop lever angle

Test data 101606-0090
N:Pump normal S:Stop the pump. (1)Use the pin at R = aa
----------
aa=45mm
----------
a=12.5deg+-5deg b=40deg+-5deg

0000001501 RACK SENSOR

Test data 101606-0090
Rack sensor adjustment 1. Flange type rack sensor (rack sensor adjustment -5*20) (1)These types of rack sensors do not need adjustment. Confirm the performance with the following procedures. (2)Mount the rack sensor main body to the pump main body. (3)Fix the pump lever at full. (4)At supply voltage V1, pump speed N1 and rack position Ra, confirm that the amp's output voltage is Vist. (5)Move the pump lever two or three times. (6)Set again to full. (7)Confirm that the amplifier output voltage is Vist. (8)Fix the caution plate to the upper part of the rack sensor. (For those without the caution plate instructions, make sure the nameplate of the rack sensor carries the "Don't hold here" caution.) (9)Apply red paint to the rack sensor mounting bolts (2 places).
----------
V1=5+-0.01V N1=850r/min Ra=R1(14.5)mm Vist=3.74+-0.28V
----------

Timing setting

Test data 101606-0090
(1)Pump vertical direction (2)Positions of coupling's threaded installation holes at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=6deg
----------
a=(160deg)




Have questions with 101606-0090?





Group cross 101606-0090 ZEXEL

Isuzu 

 
8943906053 
INJECTION-PUMP ASSEMBLY
6HH1-N
 
8943906054 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8943906056 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 611 702 
8943906057 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8943921080 
INJECTION-PUMP ASSEMBLY
6HH1
 
8943921081 
INJECTION-PUMP ASSEMBLY
6HH1
9 400 615 401 
8943921082 
INJECTION-PUMP ASSEMBLY
6HH1
 
8943925360 
INJECTION-PUMP ASSEMBLY
6HH1-C
 
8943925361 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8943925363 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 703 
8943925364 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8943925370 
INJECTION-PUMP ASSEMBLY
6HH1-N
 
8943925371 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8943925373 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 615 402 
8943925374 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8943927080 
INJECTION-PUMP ASSEMBLY
6HE1-TCN
9 400 615 403 
8943927081 
INJECTION-PUMP ASSEMBLY
6HE1-TCN
 
8943928370 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8943928371 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 704 
8943928372 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8943928380 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8943928381 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 611 705 
8943928382 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8943928390 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8943928391 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 615 404 
8943928392 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8943928400 
INJECTION-PUMP ASSEMBLY
6HL1-N
 
8943928401 
INJECTION-PUMP ASSEMBLY
6HL1-N
9 400 615 405 
8943928402 
INJECTION-PUMP ASSEMBLY
6HL1-N
101606-0090  

101606-0091 
 
8976000010 
INJECTION-PUMP ASSEMBLY
6HL1-S
 
8976000012 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 515 
8976000013 
INJECTION-PUMP ASSEMBLY
6HL1-S
9 400 611 706 
8976000014 
INJECTION-PUMP ASSEMBLY
6HL1-S
Back to top