101603-7521 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016037521 8943969221


101603-7521 INJECTION-PUMP ASSEMBLY
Rating:
12
Buy INJECTION-PUMP ASSEMBLY 101603-7521 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-7521 1016037521
ISUZU 8943969221 8943969221

Cross reference number

ZEXEL 101603-7521 1016037521
ISUZU 8943969221 8943969221


Zexel num
Bosch num
Firm num
Name
101603-7521 
101603-7522 
 
8943969221  ISUZU
INJECTION-PUMP ASSEMBLY
6HE1-S * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8210
Nozzle   105780-0070
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   4.2 4.15 4.25
Rack position
After adjusting injection quantity.
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.2
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   73.5 71.9 75.1
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   260 260 260
Average injection quantity mm3/st.   8.3 7 9.6
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.2)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   73.5 72.5 74.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.1
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   84.6 80.6 88.6
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.3
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   55.3 52.1 58.5
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   103 103 135
Fixing the lever   *
Timer adjustment
Pump speed r/min   1270--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1220
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1500
Advance angle deg.   5.5 5 6
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-7521
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=F10
----------

Speed control lever angle

Test data 101603-7521
F:Full speed I:Idle (1)Use the pin at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=11deg+-5deg b=(36.5deg)+-3deg

Stop lever angle

Test data 101603-7521
N:Pump normal S:Stop the pump. (1)Use the pin at R = aa
----------
aa=60mm
----------
a=16deg+-5deg b=29deg+-5deg

0000001501 I/P WITH LOAD PLUNGER ADJ

Plunger assembly number: PL (stamping: ST) 1. Adjustment procedures (1)Insert the pre-stroke adjusting shims L1 for each cylinder. (2)Adjust injection quantity.(max. var. bet. cyl. idling a1, full a2) (3)At basic point A, adjust so that the pre-stroke is L2. (4)Reconfirm the injection quantity.
----------
PL=131153-4520 ST=A724 L1=1mm L2=4.2+-0.05mm a1=+-14% a2=+-2.5%
----------

Timing setting

Test data 101603-7521
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)- (5)Pump vertical direction (6)Direction of rotation (7)Pointer (8)Pointer stamping (9)Timing device stamping (10)Timing device (11)Move b deg and stamp both at the same time as shown above. (12)Outside circumference of timing device (13)Secondary timing stamping position for the No. 1 cylinder's beginning of injection
----------
aa=11deg
----------
a=(150deg) b=1deg




Have questions with 101603-7521?





Group cross 101603-7521 ZEXEL

Isuzu 

 
8943969220 
INJECTION-PUMP ASSEMBLY
6HE1-S
101603-7521  

101603-7522 
 
8943969221 
INJECTION-PUMP ASSEMBLY
6HE1-S
 
8943969223 
INJECTION-PUMP ASSEMBLY
6HE1-S
 
8943969224 
INJECTION-PUMP ASSEMBLY
6HE1-S
9 400 615 190 
8943969225 
INJECTION-PUMP ASSEMBLY
6HE1-S
Back to top