6BG1-TC1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Rack position
After adjusting injection quantity.
  R=A
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   13.3
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   95.8 94.2 97.4
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Average injection quantity mm3/st.   8 6.7 9.3
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(13.3)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   95.8 94.8 96.8
Basic   *
Fixing the lever   *
Boost pressure kPa   33.3 33.3
Boost pressure mmHg   250 250
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.15
Pump speed r/min   1400 1400 1400
Average injection quantity mm3/st.   96.2 93 99.4
Fixing the lever   *
Boost pressure kPa   33.3 33.3
Boost pressure mmHg   250 250
Injection quantity adjustment_05
Adjusting point   C
Rack position   R2(R1-0. 55)
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   77.6 74.4 80.8
Fixing the lever   *
Boost pressure kPa   33.3 33.3
Boost pressure mmHg   250 250
Injection quantity adjustment_06
Adjusting point   D
Rack position   R2-1.3
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   54 50.8 57.2
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_07
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   93 93 125
Fixing the lever   *
Boost compensator adjustment
Pump speed r/min   550 550 550
Rack position   R2-1.3
Boost pressure kPa   2 2 4.7
Boost pressure mmHg   15 15 35
Boost compensator adjustment_02
Pump speed r/min   550 550 550
Rack position   R2(R1-0. 55)
Boost pressure kPa   20 20 20
Boost pressure mmHg   150 150 150
Timer adjustment
Pump speed r/min   (1170)
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1325
Advance angle deg.   1.5 1 2
Timer adjustment_03
Pump speed r/min   1400
Advance angle deg.   2 1.5 2.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-7440
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Boost compensator stroke
----------
T1=E95
----------

Speed control lever angle

Test data 101603-7440
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=43deg+-5deg b=37deg+-3deg

Stop lever angle

Test data 101603-7440
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 I/P WITH LOAD PLUNGER ADJ

Plunger assembly number: PL (stamping: ST) 1. Adjustment procedures (1)Insert the pre-stroke adjusting shims L1 for each cylinder. (2)Adjust injection quantity.(max. var. bet. cyl. idling a1, full a2) (3)At basic point A, adjust so that the pre-stroke is L2. (4)Reconfirm the injection quantity.
----------
PL=131153-4720 ST=A726 L1=1mm L2=3.6+-0.05mm a1=+-14% a2=+-2.5%
----------

Timing setting

Test data 101603-7440
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=10deg
----------
a=(60deg)




Have questions with 101603-7440?





Group cross 101603-7440 ZEXEL

Isuzu 

101603-7440  

101603-7445 
 
1156026521 
INJECTION-PUMP ASSEMBLY
6BG1-TC1
 
1156026522 
INJECTION-PUMP ASSEMBLY
6BG1-TC1
 
1156026523 
INJECTION-PUMP ASSEMBLY
6BG1-TC1
F 019 Z10 829 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

 
1156026524 
INJECTION-PUMP ASSEMBLY
6BG1-TC1
9 400 615 183 
1156026525 
INJECTION-PUMP ASSEMBLY
6BG1-TC1