101603-7081 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016037081 1156025150


101603-7081 INJECTION-PUMP ASSEMBLY
Rating:
52
Buy INJECTION-PUMP ASSEMBLY 101603-7081 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-7081 1016037081
ISUZU 1156025150 1156025150

Cross reference number

ZEXEL 101603-7081 1016037081
ISUZU 1156025150 1156025150


Zexel num
Bosch num
Firm num
Name
101603-7081 
101603-7082 
 
1156025150  ISUZU
INJECTION-PUMP ASSEMBLY
6SA1-T *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.7 3.65 3.75
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.5
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   104.6 103 106.2
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   290 290 290
Average injection quantity mm3/st.   9.9 7.9 11.9
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.5)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   104.6 103.6 105.6
Basic   *
Fixing the lever   *
Remarks
After setting aneroid compensatory.
 
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.4
Pump speed r/min   1250 1250 1250
Average injection quantity mm3/st.   99.4 96.2 102.6
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   98 98 108
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   950--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   900
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1250
Advance angle deg.   2 1.5 2.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-7081
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=E01
----------

Speed control lever angle

Test data 101603-7081
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18deg+-5deg b=31deg+-3deg

Stop lever angle

Test data 101603-7081
N:Pump normal S:Stop the pump. (1)Upper lever angle (2)Stopper bolt setting
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101603-7081
(A) Housing (B) Snap ring (C) adjusting screw (D) Set screw (E): Push rod (F) Spacer 1. Adjustment of the aneroid compensator (1)Adjust with the (D) set screw so that the clearance between the (A) housing and (B) snap ring is L1. (2)Select the push rod (E) so that the distance from the end surface of the (F) spacer becomes L2. (3)(C) Turn the screw to adjust the beginning of aneroid compensator operation. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Adjust using screw C to obtain the performance shown in the graph above. (3)After final adjustment, confirm that the gap between housing (A) and snapring (B) is L3.
----------
N1=900r/min L1=1.4~1.7mm L2=0.5+-0.5mm L3=(0.1~0.5)mm
----------
Ra=R1(12.5)mm Rb=(R1-0.45)mm Pa=92.6+-2.7kPa(695+-20mmHg) Pb=65.3+-0.7kPa(490+-5mmHg) Q1=104.6+-1cm3/1000st Q2=92.6+-1.6cm3/1000st

Timing setting

Test data 101603-7081
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=11deg
----------
a=(40deg)




Have questions with 101603-7081?





Group cross 101603-7081 ZEXEL

Isuzu 

 
1156024850 
INJECTION-PUMP ASSEMBLY
6BG1-TC
 
1156024851 
INJECTION-PUMP ASSEMBLY
6BG1-TC
9 400 615 154 
1156024852 
INJECTION-PUMP ASSEMBLY
6BG1-TC
 
1156024860 
INJECTION-PUMP ASSEMBLY
6BG1-TC
 
1156024861 
INJECTION-PUMP ASSEMBLY
6BG1-TC
 
1156024862 
INJECTION-PUMP ASSEMBLY
6BG1-TC
 
1156024821 
INJECTION-PUMP ASSEMBLY
6BG1
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

9 400 615 155 
1156024822 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156024831 
INJECTION-PUMP ASSEMBLY
6BG1
 
 
INJECTION-PUMP ASSEMBLY
9 400 615 156 
 
INJECTION-PUMP ASSEMBLY
6BG1

Isuzu 

9 400 615 156 
1156024832 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156024880 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156024881 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156025160 
INJECTION-PUMP ASSEMBLY
6SA1
9 400 615 157 
1156025161 
INJECTION-PUMP ASSEMBLY
6SA1
F 019 Z10 597 
1156025050 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156025060 
INJECTION-PUMP ASSEMBLY
6QA1
9 400 615 158 
1156025061 
INJECTION-PUMP ASSEMBLY
6QA1
101603-7081  

101603-7082 
 
1156025150 
INJECTION-PUMP ASSEMBLY
6SA1-T
9 400 615 159 
 
INJECTION-PUMP ASSEMBLY
6SA1-T

Isuzu 

9 400 615 159 
1156025151 
INJECTION-PUMP ASSEMBLY
6SA1-T
9 400 619 721 
1156025330 
INJECTION-PUMP ASSEMBLY
6SA1-T
Back to top