101603-4900 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016034900 1156024042


101603-4900 INJECTION-PUMP ASSEMBLY
Rating:
83
Buy INJECTION-PUMP ASSEMBLY 101603-4900 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-4900 1016034900
ISUZU 1156024042 1156024042

Cross reference number

ZEXEL 101603-4900 1016034900
ISUZU 1156024042 1156024042


Zexel num
Bosch num
Firm num
Name
101603-4900 
 
1156024042  ISUZU
INJECTION-PUMP ASSEMBLY
6BD1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.9
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   60.3 58.7 61.9
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   8.7 7.4 10
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.9)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   60.3 59.3 61.3
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.1
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   65.2 63.6 66.8
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.05
Pump speed r/min   1300 1300 1300
Average injection quantity mm3/st.   64 62.4 65.6
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   D
Rack position   R1(10.9)
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   46.9 45.3 48.5
Fixing the lever   *
Timer adjustment
Pump speed r/min   1050--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1300
Advance angle deg.   1.8 1.3 2.3
Timer adjustment_04
Pump speed r/min   1600
Advance angle deg.   4 3.5 4.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-4900
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT: RAL (3)Actuator operation negative pressure: P1 (4)Actuator operation negative pressure: P2
----------
T1=19 RAL=13.6+0.2mm P1=46.7kPa(350mmHg) P2=0kPa(0mmHg)
----------

Speed control lever angle

Test data 101603-4900
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position
----------
aa=45mm
----------
a=19.5deg+-5deg b=39deg+-3deg

Stop lever angle

Test data 101603-4900
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101603-4900
(A) Set screw (B) Push rod 1 (C) Push rod 2 1. Adjustment of the aneroid compensator itself and the adjustment after mounting the governor (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in (A) to obtain the performance shown in the graph (to obtain L1). (3)Adjust the (D) spacer so that dimension L2 is obtained. (4)As there is hysterisis, measure when the absolute pressure drops. (5)Hysterisis must not exceed rack position = h1.
----------
N1=1000r/min L1=1.5+-0.5mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(10.9)mm Rb=R3mm P1=89.8+-2.7kPa(674+-20mmHg) P2=70.1+-0.7kPa(526+-5mmHg) Q1=60.3+-1cm3/1000st Q2=(47.6)+-1.6cm3/1000st

Timing setting

Test data 101603-4900
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(60deg)




Have questions with 101603-4900?





Group cross 101603-4900 ZEXEL

Isuzu 

101603-4900  
 
1156024042 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156024032 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156024010 
INJECTION-PUMP ASSEMBLY
6BG1S
 
1156024020 
INJECTION-PUMP ASSEMBLY
6BG1N
 
1156016131 
INJECTION-PUMP ASSEMBLY
6QA1
9 400 615 103 
1156016132 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156024790 
INJECTION-PUMP ASSEMBLY
6BG1-S
 
1156013080 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156024760 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156016491 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156021470 
INJECTION-PUMP ASSEMBLY
6SD1
 
1156021471 
INJECTION-PUMP ASSEMBLY
6SD1
 
1156021472 
INJECTION-PUMP ASSEMBLY
6SD1
9 400 615 104 
1156021473 
INJECTION-PUMP ASSEMBLY
6SD1
Back to top