101603-0520 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016030520 1156017850


101603-0520 INJECTION-PUMP ASSEMBLY
Rating:
26
Buy INJECTION-PUMP ASSEMBLY 101603-0520 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-0520 1016030520
ISUZU 1156017850 1156017850

Cross reference number

ZEXEL 101603-0520 1016030520
ISUZU 1156017850 1156017850


Zexel num
Bosch num
Firm num
Name
101603-0520 
101603-0521 
 
1156017850  ISUZU
INJECTION-PUMP ASSEMBLY
6SA1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.7 3.65 3.75
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.4
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   92.8 91.2 94.4
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   250 250 250
Average injection quantity mm3/st.   11.7 9.7 13.7
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.4)
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   92.8 91.8 93.8
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.2
Pump speed r/min   550 550 550
Average injection quantity mm3/st.   83.2 80 86.4
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   R2(13.8)
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   103 103 113
Fixing the lever   *
Rack limit   *

Test data Ex:

Governor adjustment

Test data 101603-0520
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=B01
----------

Timer adjustment

Test data 101603-0520
(1)Adjusting range (2)Step response time (N): Speed of the pump (L): Load (theta) Advance angle (Srd1) Step response time 1 (Srd2) Step response time 2 1. Adjusting conditions for the variable timer (1)Adjust the clearance between the pickup and the protrusion to L.
----------
L=1.5+-0.2mm N2=800r/min C2=(6.4deg) t1=2--sec. t2=2--sec.
----------
N1=1200++r/min P1=0kPa(0kgf/cm2) P2=392kPa(4kgf/cm2) C1=6.4+-0.3deg R01=0/4load R02=4/4load

Speed control lever angle

Test data 101603-0520
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=18deg+-5deg b=33deg+-3deg

Stop lever angle

Test data 101603-0520
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 RACK SENSOR

Test data 101603-0520
(g) rack limit (h) Standard point (i) pump end face (j) Apply red paint. Rack sensor adjustment (154610-0420) 1. Rack limit adjustment (1)Fix the rack at the rack limit position Rl. (2)Attach shim (D) [shim thickness standard (17.5 - R1] to rod (C) and tighten nut (E). (3)Measure the distance X between the end face of the pump and the nut (E), and select a shim (D) so that X = 33-0.2mm. (4)Release the rack, mount the joint (B) and fix. (5)At this time, confirm that the shim (D) does not interfere with the joint (B). 2. Rack limit adjustment (amp-equipped type) (1)Screw in the bobbin (A) until it contacts the joint (B). (2)Fix the speed control lever at the full side and set the pump speed at No r/min. (3)Adjust the depth that the bobbin (A) is screwed in so that the control unit's rack sensor output voltage is VR (V), then tighten the nut (F). (If equipped with a boost compensator, perform with boost pressure applied.) (4)Apply red paint to both the joint (B) and the nut (F) join, and the joint (B) and the pump join.
----------
N=- R=R1(12.4)mm VR=2+-0.01V
----------

Timing setting

Test data 101603-0520
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(40deg)




Have questions with 101603-0520?





Group cross 101603-0520 ZEXEL

Isuzu 

 
1156018010 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156018011 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156018012 
INJECTION-PUMP ASSEMBLY
6SA1
9 400 615 003 
1156018013 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156017840 
INJECTION-PUMP ASSEMBLY
6SA1
9 400 615 004 
1156017841 
INJECTION-PUMP ASSEMBLY
6SA1
101603-0520  

101603-0521 
 
1156017850 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156017851 
INJECTION-PUMP ASSEMBLY
6SA1
 
1156017751 
INJECTION-PUMP ASSEMBLY
6BG1TC
 
1156014391 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156018070 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156018080 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156017891 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156018131 
INJECTION-PUMP ASSEMBLY
6QA1
 
1156018530 
INJECTION-PUMP ASSEMBLY
6BD1T
Back to top