101603-0480 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016030480 1156017650


101603-0480 INJECTION-PUMP ASSEMBLY
Rating:
18
Buy INJECTION-PUMP ASSEMBLY 101603-0480 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101603-0480 1016030480
ISUZU 1156017650 1156017650

Cross reference number

ZEXEL 101603-0480 1016030480
ISUZU 1156017650 1156017650


Zexel num
Bosch num
Firm num
Name
101603-0480 
 
1156017650  ISUZU
INJECTION-PUMP ASSEMBLY
6BG1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.4
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   70.7 69.1 72.3
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   -
Rack position   9.6+-0.5
Pump speed r/min   260 260 260
Average injection quantity mm3/st.   9.4 8.1 10.7
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.4)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   70.7 69.7 71.7
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.1
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   81 77.8 84.2
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   86 86 96
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1200--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1150
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1300
Advance angle deg.   2 1.5 2.5
Timer adjustment_04
Pump speed r/min   1500
Advance angle deg.   5.5 5 6
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-0480
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=A38
----------

Speed control lever angle

Test data 101603-0480
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=42deg+-5deg b=35deg+-3deg

Stop lever angle

Test data 101603-0480
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 RACK SENSOR

Test data 101603-0480
V1:Output voltage Vf:Full side output voltage F:Full-speed I:Idle (a) Speed lever (B) Full side stopper bolt (c) Nut (d) Nut (e) nut (P) Potentiometer 1. Load sensor adjustment (1)Apply voltage V to between the potentiometer (P)'s connector terminals (1) ~ (3) and measure the output voltage between (1) ~ (2). (2)Move the speed lever (A) until it contacts the full side stopper bolt (B) and then turn the nut (D) to adjust the potentiometer (P)'s output voltage to Vf. (3)Confirm that the speed lever (A) turns smoothly between idle and Full side, then fix using nut (E). (Tightening torque: 4.4~7N.m{0.5~0.7kgf.m}) (4)Move the speed lever (A) several times to contact full side stopper bolt (B) and confirm that the potentiometer (P) output voltage is Vf. (5)Confirm that the speed lever (A) turns smoothly between idle and Full (b deg).
----------
V=DC24V Vf=16+-0.1V
----------

Timing setting

Test data 101603-0480
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(60deg)




Have questions with 101603-0480?





Group cross 101603-0480 ZEXEL

Isuzu 

 
1156015412 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156015442 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156017620 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156017680 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017700 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017701 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017703 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017730 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017731 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017732 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017733 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017740 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017741 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 615 001 
1156017742 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017642 
INJECTION-PUMP ASSEMBLY
6BG1
9 400 615 002 
1156017644 
INJECTION-PUMP ASSEMBLY
6BG1
101603-0480  
 
1156017650 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156017660 
INJECTION-PUMP ASSEMBLY
6BG1
Back to top