6BD1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   A
Rack position   8.9
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   61.3 59.8 62.8
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_02
Adjusting point   B
Rack position   6.7+-0.5
Pump speed r/min   290 290 290
Average injection quantity mm3/st.   9.2 7.9 10.5
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Injection quantity adjustment_03
Adjusting point   C
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   50 50
Fixing the lever   *
Remarks
After startup boost setting
 
Timer adjustment
Pump speed r/min   350--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   300
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   900
Advance angle deg.   2 1.5 2.5
Timer adjustment_04
Pump speed r/min   1300
Advance angle deg.   4 3.5 4.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101603-0311
N:Pump speed R:Rack position (mm) (1)Lever ratio: RT (2)Target shim dimension: TH (3)Damper spring setting: DL (4)Excess fuel setting for starting: SXL (5)Rack difference between N = N1 and N = N2 (6)Tamper proof (shaft setting) (at N = N3).
----------
RT=1 TH=1.5mm DL=3.5-0.2mm SXL=9+0.2mm N1=1300r/min N2=850r/min N3=1300r/min
----------

0000000901

Test data 101603-0311
F:Full load I:Idle (1)Stopper bolt setting
----------

----------
a=21deg+-3deg b=33deg+-5deg

Stop lever angle

Test data 101603-0311
N:Pump normal S:Stop the pump.
----------

----------
a=35.5deg+-5deg b=71deg+-5deg

0000001501 TAMPER PROOF

Test data 101603-0311
N:Pump speed (r/min) R:Rack position (mm) 1. After governor adjustment, adjust the shaft as described below and stamp the cap. (1)Turn the load lever stopper bolt determining the full rack position (R = Ra) 1 - 2 turns counter clockwise. (2)Then, increase the full rack position. (3)Operate the pump at N = N1 and turn the shaft (A) clockwise. (4)Adjust to obtain the full rack +0.4 (R = Rb) (5)Tighten nut (B) to the specified torque. (6)Turn the stopper bolt clockwise the same amount that it was turned counter clockwise in (1). (7)Then, align with the full rack position (R = Ra) and fix. (8)Apply thread lock adhesive to the entire circumference of the cap (C) and tap it down to pressfit and seal it.. (9)Check for air tightness.
----------
N1=1300r/min Ra=8.7mm Rb=9.1mm
----------
T1=4.9~7N-m(0.5~0.7kgf-m)

Timing setting

Test data 101603-0311
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=14deg
----------
a=(60deg)




Have questions with 101603-0311?





Group cross 101603-0311 ZEXEL

Isuzu 

 
1156018050 
INJECTION-PUMP ASSEMBLY
6BD1
101603-0311  

101603-0313 
 
1156018051 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156018054 
INJECTION-PUMP ASSEMBLY
6BD1
9 400 614 999 
 
INJECTION-PUMP ASSEMBLY
6BD1

Isuzu 

9 400 614 999 
1156018056 
INJECTION-PUMP ASSEMBLY
6BD1
Back to top