101602-5100 ZEXEL 9 400 614 868 BOSCH INJECTION-PUMP ASSEMBLY 9400614868 1016025100 220206410a


101602-5100 INJECTION-PUMP ASSEMBLY
Rating:
66
Buy INJECTION-PUMP ASSEMBLY 101602-5100 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 614 868 9400614868
ZEXEL 101602-5100 1016025100
HINO 220206410A 220206410a

Service parts 101602-5100 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-6840
3. GOVERNOR 105411-2750
4. SUPPLY PUMP 105210-6060
5. AUTOM. ADVANCE MECHANIS
6. COUPLING PLATE 105662-1520
7. COUPLING PLATE 156639-8920
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-8601
11. Nozzle and Holder 236003411A
12. Open Pre:MPa(Kqf/cm2) 16.7{170}/21.6{220]
13. NOZZLE-HOLDER 105030-3700
14. NOZZLE
15. NOZZLE SET 105019-2611

Include in #1:

101602-5100 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 614 868 9400614868
ZEXEL 101602-5100 1016025100
HINO 220206410A 220206410a


Zexel num
Bosch num
Firm num
Name
101602-5100 
101602-5101 
9 400 614 868 
220206410A  HINO
INJECTION-PUMP ASSEMBLY
J08C-TI * K 14BN PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-0620
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   255 255 255
Tester oil delivery pressure kgf/cm2   2.6 2.6 2.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3.8 3.77 3.83
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   A
Rack position   9.5
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   102 100 104
Max. variation between cylinders %   0 -3.5 3.5
Basic   *
Fixing the lever   *
Boost pressure kPa   23.3 23.3
Boost pressure mmHg   175 175
Injection quantity adjustment_02
Adjusting point   -
Rack position   6.4+-0.5
Pump speed r/min   420 420 420
Average injection quantity mm3/st.   8 7 9
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
 
Injection quantity adjustment_03
Adjusting point   E
Rack position   9.7++
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   150 150 160
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Rack limit   *
Boost compensator adjustment
Pump speed r/min   700 700 700
Rack position   9.3
Boost pressure kPa   8 6.7 9.3
Boost pressure mmHg   60 50 70
Boost compensator adjustment_02
Pump speed r/min   700 700 700
Rack position   9.5
Boost pressure kPa   10 10 10
Boost pressure mmHg   75 75 75

Test data Ex:

Governor adjustment

Test data 101602-5100
N:Pump speed R:Rack position (mm) (1)Notch fixed: K (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT (4)Set idle sub-spring (5)Main spring setting (6)Damper spring setting: DL (7)Boost compensator stroke: BCL
----------
K=13 DL=4.5+-0.1mm BCL=0.2+-0.1mm
----------

Speed control lever angle

Test data 101602-5100
F:Full speed I:Idle (1)Stopper bolt setting (2)Use the hole at R = aa
----------
aa=100mm
----------
a=(16deg)+-5deg b=(27deg)+-5deg

Stop lever angle

Test data 101602-5100
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa (2)Speed = bb, rack position = cc (sealed at delivery) (3)Normal
----------
aa=25mm bb=1-0.5mm cc=0r/min
----------
a=21deg+-5deg b=(55deg)

Timing setting

Test data 101602-5100
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(20deg)




Have questions with 101602-5100?





Group cross 101602-5100 ZEXEL

Hino 

101602-5100  

101602-5101 
9 400 614 868 
220206410A 
INJECTION-PUMP ASSEMBLY
J08C-TI
9 400 613 497 
220206410B 
INJECTION-PUMP ASSEMBLY
J08C-TI
F 019 Z10 980 
220206410C 
INJECTION-PUMP ASSEMBLY
J08C-TI
9 400 613 466 
220206400A 
INJECTION-PUMP ASSEMBLY
J08C-TI
F 019 Z10 796 
220206400B 
INJECTION-PUMP ASSEMBLY
J08C-TI
9 400 613 467 
220206460A 
INJECTION-PUMP ASSEMBLY
J08C-TI
F 019 Z10 981 
220206460B 
INJECTION-PUMP ASSEMBLY
J08C-TI
9 400 619 575 
220206490A 
INJECTION-PUMP ASSEMBLY
J08C-T
Back to top