101601-8132 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016018132 1156013382


101601-8132 INJECTION-PUMP ASSEMBLY
Rating:
66
Buy INJECTION-PUMP ASSEMBLY 101601-8132 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101601-8132 1016018132
ISUZU 1156013382 1156013382

Cross reference number

ZEXEL 101601-8132 1016018132
ISUZU 1156013382 1156013382


Zexel num
Bosch num
Firm num
Name
101601-8132 
101601-8134 
 
1156013382  ISUZU
INJECTION-PUMP ASSEMBLY
6BG1 *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   132424-0620
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.6 3.55 3.65
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.7
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   78 76.4 79.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   260 260 260
Average injection quantity mm3/st.   8.1 6.8 9.4
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.7)
Pump speed r/min   1000 1000 1000
Average injection quantity mm3/st.   78 77 79
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   I
Rack position   15+-0.5
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   92 92 100
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1350--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1300
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1400
Advance angle deg.   2 1.5 2.5
Timer adjustment_04
Pump speed r/min   1500
Advance angle deg.   4.5 4 5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101601-8132
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=78
----------

Speed control lever angle

Test data 101601-8132
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=35mm
----------
a=42deg+-5deg b=(45deg)+-3deg

Stop lever angle

Test data 101601-8132
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 RACK SENSOR

Test data 101601-8132
V1:Output voltage Vf:Full side output voltage F:Full-speed I:Idle (a) Speed lever (B) Full side stopper bolt (c) Nut (d) Nut (e) nut (P) Potentiometer 1. Load sensor adjustment (1)Apply voltage V to between the potentiometer (P)'s connector terminals (1) ~ (3) and measure the output voltage between (1) ~ (2). (2)Move the speed lever (A) until it contacts the full side stopper bolt (B) and then turn the nut (D) to adjust the potentiometer (P)'s output voltage to Vf. (3)Confirm that the speed lever (A) turns smoothly between idle and Full side, then fix using nut (E). (Tightening torque: 4.4~7N.m{0.5~0.7kgf.m}) (4)Move the speed lever (A) several times to contact full side stopper bolt (B) and confirm that the potentiometer (P) output voltage is Vf. (5)Confirm that the speed lever (A) turns smoothly between idle and Full (b deg).
----------
V=DC24V Vf=16+-0.1V
----------

Timing setting

Test data 101601-8132
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(60deg)




Have questions with 101601-8132?





Group cross 101601-8132 ZEXEL

Isuzu 

 
1156013380 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013381 
INJECTION-PUMP ASSEMBLY
6BG1
101601-8132  

101601-8134 
 
1156013382 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013384 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013385 
INJECTION-PUMP ASSEMBLY
6BG1