101601-8002 ZEXEL F 019 Z20 461 BOSCH INJECTION-PUMP ASSEMBLY f019z20461 1016018002 1156014131


101601-8002 INJECTION-PUMP ASSEMBLY
Rating:
30
Buy INJECTION-PUMP ASSEMBLY 101601-8002 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH F 019 Z20 461 f019z20461
ZEXEL 101601-8002 1016018002
ISUZU 1156014131 1156014131

Include in #1:

Cross reference number

BOSCH F 019 Z20 461 f019z20461
ZEXEL 101601-8002 1016018002
ISUZU 1156014131 1156014131


Zexel num
Bosch num
Firm num
Name
101601-8002 
F 019 Z20 461 
1156014131  ISUZU
INJECTION-PUMP ASSEMBLY
6BD1-T * K 14BE PE6A PE
101601-8002 
F 019 Z20 461 
1156014132  ISUZU
INJECTION-PUMP ASSEMBLY
6BD1-T A * K 14BE PE6A PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve opening pressure kPa   157 123 191
Overflow valve opening pressure kgf/cm2   1.6 1.25 1.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-5-3-6- 2-4
Pre-stroke mm   3.4 3.35 3.45
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-5
deg.   60 59.5 60.5
Difference between angles 2
Cal 1-3
deg.   120 119.5 120.5
Difference between angles 3
Cal 1-6
deg.   180 179.5 180.5
Difference between angles 4
Cyl.1-2
deg.   240 239.5 240.5
Difference between angles 5
Cal 1-4
deg.   300 299.5 300.5
Injection quantity adjustment
Adjusting point   -
Rack position   11.6
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   72.7 71.7 73.7
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   275 275 275
Average injection quantity mm3/st.   9.4 8.1 10.7
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.6)
Pump speed r/min   950 950 950
Average injection quantity mm3/st.   72.7 71.7 73.7
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1(11.6)
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   81.1 77.9 84.3
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.15
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   56.7 53.5 59.9
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   I
Rack position   13.3+-0. 5
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   79 79 84
Fixing the rack   *
Rack limit   *
Timer adjustment
Pump speed r/min   1050--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1150
Advance angle deg.   0.5 0.5 1.1
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101601-8002
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=A28
----------

Speed control lever angle

Test data 101601-8002
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=34deg+-5deg b=36deg+-3deg

Stop lever angle

Test data 101601-8002
N:Pump normal S:Stop the pump.
----------

----------
a=25deg+-5deg b=40deg+-5deg

0000001501 ACS

Test data 101601-8002
(A) Set screw (B) Push rod 1 (C) Push rod 2 (D) Cover 1. Aneroid compensator unit adjustment (1)Select the push rod 2 to obtain L2. (2)Screw in (A) to obtain L1. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above. (3)As there is hysterisis, measure when the absolute pressure drops. (4)Hysterisis must not exceed rack position = h1.
----------
N1=950r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(11.6)mm Rb=R4(11.4)mm Pa=89.9+-2.7kPa(674+-20mmHg) Pb=70.1+-0.7kPa(526+-5mmHg) Q1=72.7+-1cm3/1000st Q2=70.2+-1.6cm3/1000st

Timing setting

Test data 101601-8002
(1)Pump vertical direction (2)Position of timer's threaded hole at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=16deg
----------
a=(60deg)




Have questions with 101601-8002?





Group cross 101601-8002 ZEXEL

Isuzu 

 
1156014130 
INJECTION-PUMP ASSEMBLY
6BD1T
 
 
INJECTION-PUMP ASSEMBLY
6BD1T
101601-8002  
F 019 Z20 461 
1156014131 
INJECTION-PUMP ASSEMBLY
6BD1-T
101601-8002  
F 019 Z20 461 
1156014132 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156014100 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156014101 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156014120 
INJECTION-PUMP ASSEMBLY
6BD1T
 
 
INJECTION-PUMP ASSEMBLY
6BD1T
 
1156014121 
INJECTION-PUMP ASSEMBLY
6BD1-T
 
1156013020 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013021 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013022 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013091 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013092 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013093 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013111 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013112 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013113 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156014352 
INJECTION-PUMP ASSEMBLY
6BD1
 
1156013130 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013131 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013132 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013133 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013150 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013151 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013152 
INJECTION-PUMP ASSEMBLY
6BG1
 
1156013153 
INJECTION-PUMP ASSEMBLY
6BG1