Rating:
Information injection-pump assembly
ZEXEL
101601-6180
1016016180
MITSUBISHI
ME03664701
me03664701
Service parts 101601-6180 INJECTION-PUMP ASSEMBLY:
1.
_
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
ME036780
12.
Open Pre:MPa(Kqf/cm2)
21.6{220}
15.
NOZZLE SET
Cross reference number
ZEXEL
101601-6180
1016016180
MITSUBISHI
ME03664701
me03664701
Zexel num
Bosch num
Firm num
Name
101601-6180
ME03664701 MITSUBISHI
INJECTION-PUMP ASSEMBLY
6D14 * K 14BE PE6A PE
6D14 * K 14BE PE6A PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Overflow valve
131424-3720
Overflow valve opening pressure
kPa
255
221
289
Overflow valve opening pressure
kgf/cm2
2.6
2.25
2.95
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Left L
Left L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left L
Left L
Injection order
1-5-3-6-
2-4
Pre-stroke
mm
3.3
3.25
3.35
Beginning of injection position
Governor side NO.1
Governor side NO.1
Difference between angles 1
Cal 1-5 deg. 60 59.5 60.5
Cal 1-5 deg. 60 59.5 60.5
Difference between angles 2
Cal 1-3 deg. 120 119.5 120.5
Cal 1-3 deg. 120 119.5 120.5
Difference between angles 3
Cal 1-6 deg. 180 179.5 180.5
Cal 1-6 deg. 180 179.5 180.5
Difference between angles 4
Cyl.1-2 deg. 240 239.5 240.5
Cyl.1-2 deg. 240 239.5 240.5
Difference between angles 5
Cal 1-4 deg. 300 299.5 300.5
Cal 1-4 deg. 300 299.5 300.5
Injection quantity adjustment
Adjusting point
-
Rack position
11
Pump speed
r/min
1000
1000
1000
Each cylinder's injection qty
mm3/st.
67
65
69
Basic
*
Fixing the rack
*
Injection quantity adjustment_02
Adjusting point
C
Rack position
8.8+-0.5
Pump speed
r/min
275
275
275
Each cylinder's injection qty
mm3/st.
6.8
5.8
7.8
Fixing the rack
*
Injection quantity adjustment_03
Adjusting point
B
Rack position
R(11+-0.
5)
Pump speed
r/min
1000
1000
1000
Average injection quantity
mm3/st.
67
66
68
Fixing the lever
*
Injection quantity adjustment_04
Adjusting point
A
Rack position
R(11+-0.
5)
Pump speed
r/min
1580
1580
1580
Average injection quantity
mm3/st.
67
63
71
Difference in delivery
mm3/st.
6
6
6
Fixing the lever
*
Timer adjustment
Pump speed
r/min
1000+-50
Advance angle
deg.
0
0
0
Remarks
Start
Start
Timer adjustment_02
Pump speed
r/min
1300
Advance angle
deg.
1
0.5
1.5
Timer adjustment_03
Pump speed
r/min
1600
Advance angle
deg.
2
1.5
2.5
Remarks
Finish
Finish
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Beginning of damper spring operation: DL
(2)Excess fuel setting for starting: SXL
----------
DL=6.5-0.5mm SXL=11+0.7+0.5mm
----------
----------
DL=6.5-0.5mm SXL=11+0.7+0.5mm
----------
0000000901
F:Full load
I:Idle
----------
----------
a=33deg+-5deg b=30deg+-3deg
----------
----------
a=33deg+-5deg b=30deg+-3deg
Stop lever angle
N:Pump normal
S:Stop the pump.
----------
----------
a=20deg+-5deg b=71deg+-3deg
----------
----------
a=20deg+-5deg b=71deg+-3deg
Have questions with 101601-6180?
Group cross 101601-6180 ZEXEL
Mitsubishi
101601-6180
ME03664701
INJECTION-PUMP ASSEMBLY
6D14
6D14