101601-5794 ZEXEL 9 400 611 506 BOSCH INJECTION-PUMP ASSEMBLY 9400611506 1016015794 220007313a


101601-5794 INJECTION-PUMP ASSEMBLY
Rating:
21
Buy INJECTION-PUMP ASSEMBLY 101601-5794 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 611 506 9400611506
ZEXEL 101601-5794 1016015794
HINO 220007313A 220007313a

Service parts 101601-5794 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-5210
3. GOVERNOR 105921-8440
4. SUPPLY PUMP 105210-5240
5. AUTOM. ADVANCE MECHANIS 105672-0350
6. COUPLING PLATE 105662-1160
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105101-6610
11. Nozzle and Holder 23600-2360A
12. Open Pre:MPa(Kqf/cm2) 19.6{200}
13. NOZZLE-HOLDER 105030-4410
14. NOZZLE 105015-8980
15. NOZZLE SET

Include in #1:

101601-5794 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 611 506 9400611506
ZEXEL 101601-5794 1016015794
HINO 220007313A 220007313a


Zexel num
Bosch num
Firm num
Name
101601-5794 
9 400 611 506 
220007313A  HINO
INJECTION-PUMP ASSEMBLY
H07D-A K 14BF INJECTION PUMP ASSY PE6AD PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-8320
Overflow valve opening pressure kPa   108 88 128
Overflow valve opening pressure kgf/cm2   1.1 0.9 1.3
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3.8 3.77 3.83
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   -
Rack position   11.7
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   81.5 79.9 83.1
Max. variation between cylinders %   0 -3.5 3.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9+-0.5
Pump speed r/min   300 300 300
Each cylinder's injection qty mm3/st.   15.5 14.5 16.5
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.7)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   81.5 80.5 82.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.5
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   91.5 87.5 95.5
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.3
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   70.5 66.5 74.5
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   D
Rack position   R1+0.5
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   91.5 87.5 95.5
Fixing the lever   *
Injection quantity adjustment_07
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   140 140 150
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   900--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   850
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   1450
Advance angle deg.   2.5 2.2 2.8
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101601-5794
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=F03
----------

Speed control lever angle

Test data 101601-5794
F:Full speed I:Idle (1)Use the pin at R = aa (2)Stopper bolt setting
----------
aa=57mm
----------
a=38deg+-3deg b=41deg+-5deg

Stop lever angle

Test data 101601-5794
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=35mm
----------
a=14.5deg+-5deg b=40deg+-5deg

0000001501 TAMPER PROOF

Test data 101601-5794
1. Method for setting tamperproof proofing (1)Perform after governor adjustment (torque cam phase adjustment). (2)Increase the full rack position to Ra using the load lever. (3)Push in screw (A) to Rb. (4)Temporarily caulk using the tip of a screwdriver (5)Confirm that the rack at that time is at Rb . (6)Lock using setscrew (B). (Tightening torque = T) (7)Pressfit (C) after applying adhesive. (8)Readjust the full rack using the load lever.
----------
Ra=(R1+1)+-0.1mm Rb=(R1+1)+-0.1mm
----------
T=4.9~7N-m(0.5~0.7Kgf-m)

Timing setting

Test data 101601-5794
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(50deg)




Have questions with 101601-5794?





Group cross 101601-5794 ZEXEL

Hino 

F 019 Z10 820 
220007310A 
INJECTION-PUMP ASSEMBLY
H07D-A
F 019 Z10 821 
220007311A 
INJECTION-PUMP ASSEMBLY
H07D-A
F 019 Z10 495 
220007311B 
INJECTION-PUMP ASSEMBLY
H07D-A
F 019 Z10 496 
220007312A 
INJECTION-PUMP ASSEMBLY
H07D-A
101601-5794  
9 400 611 506 
220007313A 
INJECTION-PUMP ASSEMBLY
H07D-A
Back to top