101601-5660 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016015660 220006430a


101601-5660 INJECTION-PUMP ASSEMBLY
Rating:
17
Buy INJECTION-PUMP ASSEMBLY 101601-5660 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101601-5660 1016015660
HINO 220006430A 220006430a

Cross reference number

ZEXEL 101601-5660 1016015660
HINO 220006430A 220006430a


Zexel num
Bosch num
Firm num
Name
101601-5660 
101601-5665 
 
220006430A  HINO
INJECTION-PUMP ASSEMBLY
H07D-A *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8210
Nozzle   105780-0070
Bosch type code   DN12SD12T-1
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-0920
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3.8 3.77 3.83
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   -
Rack position   11.5
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   77.6 76 79.2
Max. variation between cylinders %   0 -3.5 3.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9+-0.5
Pump speed r/min   250 250 250
Each cylinder's injection qty mm3/st.   16.9 15.9 17.9
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.5)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   77.6 76.6 78.6
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.5
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   88.9 84.9 92.9
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.3
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   64.2 60.2 68.2
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   D
Rack position   R1+0.5
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   87.4 83.4 91.4
Fixing the lever   *
Injection quantity adjustment_07
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   140 140 150
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   925--
Advance angle deg.   0 0 0
Load   1/4
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   875
Advance angle deg.   0.3
Load   1/4
Timer adjustment_03
Pump speed r/min   (920--)
Advance angle deg.   1 0.7 1.3
Load   4/4
Timer adjustment_04
Pump speed r/min   1175+50
Advance angle deg.   1 0.7 1.3
Load   3/4
Timer adjustment_05
Pump speed r/min   1400+50
Advance angle deg.   5.5 5.2 5.8
Load   4/4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101601-5660
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=F80
----------

Speed control lever angle

Test data 101601-5660
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=55mm
----------
a=37deg+-3deg b=40deg+-5deg

Stop lever angle

Test data 101601-5660
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=35mm
----------
a=14.5deg+-5deg b=40deg+-5deg

0000001501 AIR CYLINDER

Test data 101601-5660
(A): Speed lever (B): Set bolt (C): air cylinder (D): nut (E): fix 1. Air cylinder adjustment procedure (1)With the speed lever in the idling position, temporarily set the clearance between speed lever (A) and set bolt (B) at approximately L1. (2)Set the speed to N1 and supply positive pressure P1 to the air cylinder (C). (3)Gradually push set bolt (B) out (approximately L2) and tighten nut (D) where the speed is N2 and the rack position is Ra. (4)Apply positive pressure P1 several times. (5)Confirm that the lever returns to the idle position at positive pressure P2. (6)Also, confirm that the rack position is Rb at air pressure P1.
----------
L=0.6++mm L1=5mm L2=- Ra=8.8+-0.1mm Rb=8.8+-0.1mm N1=475r/min N2=475r/min P1=392+98kPa(4+1kgf/cm2) P2=0kPa(0kgf/cm2)
----------

Timing setting

Test data 101601-5660
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(50deg)




Have questions with 101601-5660?





Group cross 101601-5660 ZEXEL

Hino 

101601-5660  

101601-5665 
 
220006430A 
INJECTION-PUMP ASSEMBLY
H07D-A
 
220006431A 
INJECTION-PUMP ASSEMBLY
H07D-A
 
220006431B 
INJECTION-PUMP ASSEMBLY
H07D-A
F 019 Z20 457 
220006432A 
INJECTION-PUMP ASSEMBLY
H07D-A
F 019 Z10 491 
220006433A 
INJECTION-PUMP ASSEMBLY
H07D-A
Back to top