101601-5620 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016015620 220006411a


101601-5620 INJECTION-PUMP ASSEMBLY
Rating:
20
Buy INJECTION-PUMP ASSEMBLY 101601-5620 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101601-5620 1016015620
HINO 220006411A 220006411a

Cross reference number

ZEXEL 101601-5620 1016015620
HINO 220006411A 220006411a


Zexel num
Bosch num
Firm num
Name
101601-5620 
101601-5625 
 
220006411A  HINO
INJECTION-PUMP ASSEMBLY
H07D-A *

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8210
Nozzle   105780-0070
Bosch type code   DN12SD12T-1
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-0920
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3.8 3.77 3.83
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   -
Rack position   11.5
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   77.6 76 79.2
Max. variation between cylinders %   0 -3.5 3.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9+-0.5
Pump speed r/min   250 250 250
Each cylinder's injection qty mm3/st.   16.9 15.9 17.9
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(11.5)
Pump speed r/min   850 850 850
Average injection quantity mm3/st.   77.6 76.6 78.6
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.5
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   88.9 84.9 92.9
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.3
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   64.2 60.2 68.2
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   D
Rack position   R1+0.5
Pump speed r/min   1150 1150 1150
Average injection quantity mm3/st.   87.4 83.4 91.4
Fixing the lever   *
Injection quantity adjustment_07
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   140 140 150
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   925--
Advance angle deg.   0 0 0
Load   1/4
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   875
Advance angle deg.   0.3
Load   1/4
Timer adjustment_03
Pump speed r/min   (920--)
Advance angle deg.   1 0.7 1.3
Load   4/4
Timer adjustment_04
Pump speed r/min   1175+50
Advance angle deg.   1 0.7 1.3
Load   3/4
Timer adjustment_05
Pump speed r/min   1400+50
Advance angle deg.   5.5 5.2 5.8
Load   4/4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101601-5620
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT
----------
T1=F80
----------

Speed control lever angle

Test data 101601-5620
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=55mm
----------
a=37deg+-3deg b=40deg+-5deg

Stop lever angle

Test data 101601-5620
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=35mm
----------
a=14.5deg+-5deg b=40deg+-5deg

Timing setting

Test data 101601-5620
(1)Pump vertical direction (2)Coupling's key groove position at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(50deg)




Have questions with 101601-5620?





Group cross 101601-5620 ZEXEL

Hino 

101601-5620  

101601-5625 
 
220006411A 
INJECTION-PUMP ASSEMBLY
H07D-A
 
220006412A 
INJECTION-PUMP ASSEMBLY
H07D-A
 
220006412B 
INJECTION-PUMP ASSEMBLY
H07D-A
F 019 Z20 455 
220006413A 
INJECTION-PUMP ASSEMBLY
H07D-A
F 019 Z10 490 
220006414A 
INJECTION-PUMP ASSEMBLY
H07D-A
Back to top