101601-5154 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1016015154 220004992a


101601-5154 INJECTION-PUMP ASSEMBLY
Rating:
11
Buy INJECTION-PUMP ASSEMBLY 101601-5154 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101601-5154 1016015154
HINO 220004992A 220004992a

Service parts 101601-5154 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101060-9931
3. GOVERNOR 105921-1612
4. SUPPLY PUMP 105220-5140
5. AUTOM. ADVANCE MECHANIS 105676-0281
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-4350
11. Nozzle and Holder 236001730A
12. Open Pre:MPa(Kqf/cm2) 21.6(220)
13. NOZZLE-HOLDER 105041-5070
14. NOZZLE 105015-6760
15. NOZZLE SET

Include in #1:

101601-5154 as INJECTION-PUMP ASSEMBLY

Cross reference number

ZEXEL 101601-5154 1016015154
HINO 220004992A 220004992a


Zexel num
Bosch num
Firm num
Name
101601-5154 
 
220004992A  HINO
INJECTION-PUMP ASSEMBLY
W06E * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-5720
Overflow valve opening pressure kPa   255 221 289
Overflow valve opening pressure kgf/cm2   2.6 2.25 2.95
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-4-2-6- 3-5
Pre-stroke mm   3.1 3.07 3.13
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-4
deg.   60 59.75 60.25
Difference between angles 2
Cyl.1-2
deg.   120 119.75 120.25
Difference between angles 3
Cal 1-6
deg.   180 179.75 180.25
Difference between angles 4
Cal 1-3
deg.   240 239.75 240.25
Difference between angles 5
Cal 1-5
deg.   300 299.75 300.25
Injection quantity adjustment
Adjusting point   -
Rack position   8.9
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   47.4 45.4 49.4
Max. variation between cylinders %   0 -3.5 3.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   8+-0.5
Pump speed r/min   250 250 250
Average injection quantity mm3/st.   6.8 5.3 8.3
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(8.9)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   47.4 46.4 48.4
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.15
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   56.3 52.3 60.3
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.15
Pump speed r/min   600 600 600
Average injection quantity mm3/st.   36.7 32.7 40.7
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   D
Rack position   (R1+0.1)
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   52.2 48.2 56.2
Fixing the lever   *
Injection quantity adjustment_07
Adjusting point   E
Rack position   R1+0.3
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   29.2 25.2 33.2
Fixing the lever   *
Injection quantity adjustment_08
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   99 99 109
Fixing the lever   *
Rack limit   *
Timer adjustment
Pump speed r/min   1050--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1000
Advance angle deg.   0.3
Timer adjustment_03
Pump speed r/min   1500
Advance angle deg.   3.5 3.2 3.8
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101601-5154
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)RACK LIMIT
----------
T1=B95
----------

Speed control lever angle

Test data 101601-5154
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=32deg+-3deg b=34deg+-5deg

Stop lever angle

Test data 101601-5154
N:Pump normal S:Stop the pump.
----------

----------
a=40deg+-5deg b=40deg+-5deg

0000001501 TAMPER PROOF

Test data 101601-5154
1. Method for setting tamperproof proofing (1)After governor adjustment (torque cam phase adjustment), move the load lever to increase the full rack position to Ra. (2)At pump speed N1, push in the screw (A) until the rack position is Rb. (3)Temporarily caulk using the tip of a screwdriver (4)Confirm that the rack at that time is at Rc. (5)Lock using setscrew (B). (Tightening torque = T) (6)Next, coat (C) with adhesive and then pressfit. (7)Then, readjust the full rack position using the load lever.
----------
N1=1500r/min Ra=(0.4)mm Rb=R1(8.9)+0.4mm Rc=R1(8.9)+0.4mm
----------
T=3.4~4.9N-m(0.35~0.5Kgf-m)

Timing setting

Test data 101601-5154
(1)Pump vertical direction (2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(70deg)




Have questions with 101601-5154?





Group cross 101601-5154 ZEXEL

Hino 

 
220004990A 
INJECTION-PUMP ASSEMBLY
W06E
 
 
INJECTION-PUMP ASSEMBLY
W06E
 
220004991A 
INJECTION-PUMP ASSEMBLY
W06E
 
 
INJECTION-PUMP ASSEMBLY

Hino 

101601-5154  
 
220004992A 
INJECTION-PUMP ASSEMBLY
W06E
Back to top