Rating:
Information injection-pump assembly
BOSCH
9 400 614 461
9400614461
ZEXEL
101492-3980
1014923980
KOMATSU
6204711241
6204711241
Service parts 101492-3980 INJECTION-PUMP ASSEMBLY:
1.
_
5.
AUTOM. ADVANCE MECHANIS
6.
COUPLING PLATE
7.
COUPLING PLATE
8.
_
9.
_
11.
Nozzle and Holder
12.
Open Pre:MPa(Kqf/cm2)
19.6{200}
15.
NOZZLE SET
Cross reference number
BOSCH
9 400 614 461
9400614461
ZEXEL
101492-3980
1014923980
KOMATSU
6204711241
6204711241
Zexel num
Bosch num
Firm num
Name
101492-3980
9 400 614 461
6204711241 KOMATSU
INJECTION-PUMP ASSEMBLY
4D95L K 14BC INJECTION PUMP ASSY PE4A,5A, PE
4D95L K 14BC INJECTION PUMP ASSY PE4A,5A, PE
Calibration Data:
Adjustment conditions
Test oil
1404 Test oil ISO4113 or {SAEJ967d}
1404 Test oil ISO4113 or {SAEJ967d}
Test oil temperature
degC
40
40
45
Nozzle and nozzle holder
105780-8140
Bosch type code
EF8511/9A
Nozzle
105780-0000
Bosch type code
DN12SD12T
Nozzle holder
105780-2080
Bosch type code
EF8511/9
Opening pressure
MPa
17.2
Opening pressure
kgf/cm2
175
Injection pipe
Outer diameter - inner diameter - length (mm) mm 6-2-600
Outer diameter - inner diameter - length (mm) mm 6-2-600
Tester oil delivery pressure
kPa
157
157
157
Tester oil delivery pressure
kgf/cm2
1.6
1.6
1.6
Direction of rotation (viewed from drive side)
Right R
Right R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right R
Right R
Injection order
1-2-4-3
Pre-stroke
mm
3.6
3.55
3.65
Beginning of injection position
Drive side NO.1
Drive side NO.1
Difference between angles 1
Cyl.1-2 deg. 90 89.5 90.5
Cyl.1-2 deg. 90 89.5 90.5
Difference between angles 2
Cal 1-4 deg. 180 179.5 180.5
Cal 1-4 deg. 180 179.5 180.5
Difference between angles 3
Cal 1-3 deg. 270 269.5 270.5
Cal 1-3 deg. 270 269.5 270.5
Injection quantity adjustment
Adjusting point
A
Rack position
10.4
Pump speed
r/min
1200
1200
1200
Average injection quantity
mm3/st.
36.4
35.4
37.4
Max. variation between cylinders
%
0
-2.5
2.5
Basic
*
Fixing the lever
*
Injection quantity adjustment_02
Adjusting point
-
Rack position
10.5+-0.
5
Pump speed
r/min
450
450
450
Average injection quantity
mm3/st.
10.5
9.5
11.5
Max. variation between cylinders
%
0
-15
15
Fixing the rack
*
Remarks
Adjust only variation between cylinders; adjust governor according to governor specifications.
Adjust only variation between cylinders; adjust governor according to governor specifications.
Test data Ex:
Governor adjustment
N:Pump speed
R:Rack position (mm)
(1)Target notch: K
(2)RACK LIMIT: RAL
(3)The torque control spring must does not have a set force.
(4)Rack difference between N = N1 and N = N2
----------
K=15 RAL=15+0.2mm N1=1200r/min N2=800r/min
----------
----------
K=15 RAL=15+0.2mm N1=1200r/min N2=800r/min
----------
Speed control lever angle
F:Full speed
I:Idle
S:Stop
----------
----------
a=11deg+-5deg b=32deg+-3deg c=34deg+-5deg
----------
----------
a=11deg+-5deg b=32deg+-3deg c=34deg+-5deg
Timing setting
(1)Pump vertical direction
(2)Position of key groove at No 1 cylinder's beginning of injection
(3)Stamp aligning marks on the pump housing flange.
(4)-
(5)-
----------
----------
a=59deg36min+-3deg b=0deg24min+-30min
----------
----------
a=59deg36min+-3deg b=0deg24min+-30min
Have questions with 101492-3980?
Group cross 101492-3980 ZEXEL
Komatsu
Komatsu
101492-3980
9 400 614 461
6204711241
INJECTION-PUMP ASSEMBLY
4D95L
4D95L