101491-0672 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014910672 8970480482


101491-0672 INJECTION-PUMP ASSEMBLY
Rating:
22
Buy INJECTION-PUMP ASSEMBLY 101491-0672 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101491-0672 1014910672
ISUZU 8970480482 8970480482

Cross reference number

ZEXEL 101491-0672 1014910672
ISUZU 8970480482 8970480482


Zexel num
Bosch num
Firm num
Name
101491-0672 
 
8970480482  ISUZU
INJECTION-PUMP ASSEMBLY
4BE1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   131424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.2 3.15 3.25
Rack position
Point A
  R=A
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   10.6
Pump speed r/min   1050 1050 1050
Average injection quantity mm3/st.   56.4 54.8 58
Max. variation between cylinders %   0 -4 4
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.9+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   12.5 11.2 13.8
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(10.6)
Pump speed r/min   1050 1050 1050
Average injection quantity mm3/st.   56.4 55.4 57.4
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.15
Pump speed r/min   1750 1750 1750
Average injection quantity mm3/st.   67.7 64.5 70.9
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   78.5 62.5 94.5
Fixing the lever   *
Timer adjustment
Pump speed r/min   1425--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1375
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1750
Advance angle deg.   5 4.5 5.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101491-0672
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=G35
----------

Speed control lever angle

Test data 101491-0672
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=5.5deg+-5deg b=34.5deg+-3deg

Stop lever angle

Test data 101491-0672
N:Pump normal S:Stop the pump.
----------

----------
a=45deg+-5deg b=29deg+-5deg

0000001501 ACS

Test data 101491-0672
(A) Set screw (B) Push rod 1 (C) Push rod 2 (D) Cover 1. Aneroid compensator unit adjustment (1)Select the push rod 2 to obtain L2. (2)Screw in (A) to obtain L1. 2. Adjustment when mounting the governor. (1)Set the speed of the pump to N1 r/min and fix the control lever at the full set position. (2)Screw in the aneroid compensator to obtain the performance shown in the graph above. (3)As there is hysterisis, measure when the absolute pressure drops. (4)Hysterisis must not exceed rack position = h1.
----------
N1=1050r/min L1=(1.5)mm L2=11+-0.5mm h1=0.15mm
----------
Ra=R1(10.6)mm Rb=R1-0.45mm Pa=95.4+-5.3kPa(716+-40mmHg) Pb=70.1+-0.7kPa(526+-5mmHg) Q1=56.4+-1cm3/1000st Q2=(43)+-1.6cm3/1000st

Timing setting

Test data 101491-0672
(1)Pump vertical direction (2)Position of gear mark 'CC' at No 1 cylinder's beginning of injection (3)B.T.D.C.: aa (4)-
----------
aa=17deg
----------
a=(90deg)




Have questions with 101491-0672?





Group cross 101491-0672 ZEXEL

Isuzu 

9 400 614 296 
8970251451 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970295940 
INJECTION-PUMP ASSEMBLY
4BE1
9 400 614 297 
8970386171 
INJECTION-PUMP ASSEMBLY
4BE1
9 400 614 298 
8970295951 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970331530 
INJECTION-PUMP ASSEMBLY
4BC2
F 019 Z10 579 
8970439740 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970439741 
INJECTION-PUMP ASSEMBLY
4BE1
9 400 614 299 
8970466911 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970430651 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970430652 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970480480 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970480481 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970480483 
INJECTION-PUMP ASSEMBLY
4BE1
101491-0672  
 
8970480482 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970480490 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970480491 
INJECTION-PUMP ASSEMBLY
4BE1
 
8970480492 
INJECTION-PUMP ASSEMBLY
4BE1
9 400 614 300 
8970480493 
INJECTION-PUMP ASSEMBLY
4BE1
9 400 614 301 
8970475561 
INJECTION-PUMP ASSEMBLY
4BE1
Back to top