101401-4841 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014014841 8971147580


101401-4841 INJECTION-PUMP ASSEMBLY
Rating:
52
Buy INJECTION-PUMP ASSEMBLY 101401-4841 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-4841 1014014841
ISUZU 8971147580 8971147580

Cross reference number

ZEXEL 101401-4841 1014014841
ISUZU 8971147580 8971147580


Zexel num
Bosch num
Firm num
Name
101401-4841 
 
8971147580  ISUZU
INJECTION-PUMP ASSEMBLY
4HG1 * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-3920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-3-4-2
Pre-stroke mm   4.1 4.05 4.15
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   12.5
Pump speed r/min   960 960 960
Average injection quantity mm3/st.   74.5 72.9 76.1
Max. variation between cylinders %   0 -4 4
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.8+-0.5
Pump speed r/min   285 285 285
Average injection quantity mm3/st.   10 8.7 11.3
Max. variation between cylinders %   0 -10 10
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.5)
Pump speed r/min   960 960 960
Average injection quantity mm3/st.   74.5 73.5 75.5
Basic   *
Fixing the lever   *
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.45
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   91 87 95
Fixing the lever   *
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.15
Pump speed r/min   520 520 520
Average injection quantity mm3/st.   53.5 49.5 57.5
Fixing the lever   *
Injection quantity adjustment_06
Adjusting point   D
Rack position   R1+0.25
Pump speed r/min   1310 1310 1310
Average injection quantity mm3/st.   85.5 81.5 89.5
Fixing the lever   *
Timer adjustment
Pump speed r/min   1150--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1100
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1600
Advance angle deg.   6 5.5 6.5
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-4841
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm.
----------
T1=J79
----------

Speed control lever angle

Test data 101401-4841
F:Full speed I:Idle (1)Stopper bolt set position 'H'
----------

----------
a=38deg+-5deg b=34deg+-3deg

Stop lever angle

Test data 101401-4841
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=64mm
----------
a=20deg+-5deg b=29deg+-5deg

0000001501 FICD

Test data 101401-4841
(A) applied negative pressure (B) Screw (c) Nut 1. Set the actuator as described below. (1)Confirm that there is clearance between the actuator lever and the speed lever. (2)Loosen the nut (C). (3)Push in the screw (B). (4)Apply P1 from the actuator (A) part. (5)Pull out the screw (B) slowly. (6)Tighten and fix the nut (C) when pump speed is Na and the rack position is Ra. (7)Torque the nut (C) to T1. (8)Apply P2 several times. (9)Confirm that the actuator functions normally. (10)Confirm that there is a clearance between the actuator lever and the speed lever at that time.
----------
P1=53.3kPa(400mmHg) P2=53.3kPa(400mmHg) Na=400r/min Ra=9.2+-0.1mm T1=1.2~1.6N-m(0.12~0.16kgf-m)
----------
L=(5)mm

0000001601 RACK SENSOR

Rack sensor adjustment (1)These types of rack sensors do not need adjustment. Confirm the output as described below. (2)Mount the rack sensor main body to the pump main body. (3)Measure the Vist at pump speed N1 and rack position Ra.
----------
N1=1600r/min Ra=R1(12.5)+0.45mm
----------

Timing setting

Test data 101401-4841
(1)Pump vertical direction (2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection (3)Timing device stamping (4)At the No 1 cylinder's beginning of injection, align with the aligning mark seen through the bracket's check hole and mark the A/T's bevel C1. (5)B.T.D.C.: aa
----------
aa=7deg
----------
a=(60deg) b=(85deg)




Have questions with 101401-4841?





Group cross 101401-4841 ZEXEL

Isuzu 

 
8971076500 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 725 
8971140520 
INJECTION-PUMP ASSEMBLY
4HF1
 
8971076490 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 726 
8971140510 
INJECTION-PUMP ASSEMBLY
4HF1
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

101401-4841  
 
8971147580 
INJECTION-PUMP ASSEMBLY
4HG1
 
 
INJECTION-PUMP ASSEMBLY

Isuzu 

 
8970899041 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 727 
8971140100 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 728 
8971140110 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 610 399 
8971140120 
INJECTION-PUMP ASSEMBLY
4HF1
9 400 613 729 
8971140090 
INJECTION-PUMP ASSEMBLY
4HF1
Back to top