101401-4401 ZEXEL INJECTION-PUMP ASSEMBLY Calibration Data 1014014401 8970613921


101401-4401 INJECTION-PUMP ASSEMBLY
Rating:
65
Buy INJECTION-PUMP ASSEMBLY 101401-4401 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

ZEXEL 101401-4401 1014014401
ISUZU 8970613921 8970613921

Cross reference number

ZEXEL 101401-4401 1014014401
ISUZU 8970613921 8970613921


Zexel num
Bosch num
Firm num
Name
101401-4401 
101401-4402 
 
8970613921  ISUZU
INJECTION-PUMP ASSEMBLY
4HE1-T * K

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-4920
Overflow valve opening pressure kPa   127 107 147
Overflow valve opening pressure kgf/cm2   1.3 1.1 1.5
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Left
  L
Injection timing adjustment
Direction of rotation (viewed from drive side)
Left
  L
Injection order   1-3-4-2
Pre-stroke mm   3.8 3.75 3.85
Rack position
Point A
  R=A
Beginning of injection position
Governor side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.5 90.5
Difference between angles 2
Cal 1-4
deg.   180 179.5 180.5
Difference between angles 3
Cyl.1-2
deg.   270 269.5 270.5
Injection quantity adjustment
Adjusting point   -
Rack position   13
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   93 91.4 94.6
Max. variation between cylinders %   0 -2.5 2.5
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   Z
Rack position   9.5+-0.5
Pump speed r/min   400 400 400
Average injection quantity mm3/st.   14.5 13.2 15.8
Max. variation between cylinders %   0 -14 14
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(13)
Pump speed r/min   1200 1200 1200
Average injection quantity mm3/st.   93 92 94
Basic   *
Fixing the lever   *
Boost pressure kPa   62 62
Boost pressure mmHg   465 465
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1+0.25
Pump speed r/min   1450 1450 1450
Average injection quantity mm3/st.   95.5 91.5 99.5
Fixing the lever   *
Boost pressure kPa   62 62
Boost pressure mmHg   465 465
Injection quantity adjustment_05
Adjusting point   C
Rack position   R2-0.6
Pump speed r/min   700 700 700
Average injection quantity mm3/st.   75 71 79
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_06
Adjusting point   I
Rack position   -
Pump speed r/min   150 150 150
Average injection quantity mm3/st.   55 55 87
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   700 700 700
Rack position   R2-0.6
Boost pressure kPa   26.7 25.4 28
Boost pressure mmHg   200 190 210
Boost compensator adjustment_02
Pump speed r/min   700 700 700
Rack position   R2[R1-0. 55]
Boost pressure kPa   48.7 48.7 48.7
Boost pressure mmHg   365 365 365
Timer adjustment
Pump speed r/min   1250--
Advance angle deg.   0 0 0
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   1200
Advance angle deg.   0.5
Timer adjustment_03
Pump speed r/min   1450
Advance angle deg.   3.8 3.3 4.3
Timer adjustment_04
Pump speed r/min   -
Advance angle deg.   4 3.5 4.5
Remarks
Measure the actual speed, stop
 

Test data Ex:

Governor adjustment

Test data 101401-4401
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)Boost compensator stroke: BCL
----------
T1=J03 BCL=0.6+-0.1mm
----------

Speed control lever angle

Test data 101401-4401
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=43deg+-5deg b=32deg+-3deg

Stop lever angle

Test data 101401-4401
N:Pump normal S:Stop the pump. (1)Use the hole at R = aa
----------
aa=64mm
----------
a=20deg+-5deg b=29deg+-5deg

0000001501 MICRO SWITCH

Adjustment of the micro-switch Adjust the bolt to obtain the following lever position when the micro-switch is ON. (1)Speed N1 (2)Rack position Ra
----------
N1=1100r/min Ra=9.2+-0.1mm
----------

0000001601 FICD

Test data 101401-4401
(A) applied negative pressure (B) Screw (c) Nut 1. Set the actuator as described below. (1)Confirm that there is clearance between the actuator lever and the speed lever. (2)Loosen the nut (C). (3)Push in the screw (B). (4)Apply P1 from the actuator (A) part. (5)Pull out the screw (B) slowly. (6)Tighten and fix the nut (C) when pump speed is Na and the rack position is Ra. (7)Torque the nut (C) to T1. (8)Apply P2 several times. (9)Confirm that the actuator functions normally. (10)Confirm that there is a clearance between the actuator lever and the speed lever at that time.
----------
P1=53.3kPa(400mmHg) P2=53.3kPa(400mmHg) Na=475r/min Ra=9.55+-0.1mm T1=1.2~1.6N-m(0.12~0.16kgf-m)
----------
L=(2)mm

Timing setting

Test data 101401-4401
(1)Pump vertical direction (2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection (3)Stamping position on the A/T outer rim (4)At the No 1 cylinder's beginning of injection, align with the aligning mark seen through the bracket's check hole and mark the A/T's bevel C1. (5)B.T.D.C.: aa
----------
aa=9deg
----------
a=(60deg) b=(85deg)




Have questions with 101401-4401?





Group cross 101401-4401 ZEXEL

Isuzu 

 
8970613920 
INJECTION-PUMP ASSEMBLY
4HE1-T
101401-4401  

101401-4402 
 
8970613921 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8970613923 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8971140020 
INJECTION-PUMP ASSEMBLY
4HE1-T
 
8971197170 
INJECTION-PUMP ASSEMBLY
4HE1-T
9 400 613 698 
8971295670 
INJECTION-PUMP ASSEMBLY
4HE1-T
Back to top