101401-2333 ZEXEL 9 400 613 662 BOSCH INJECTION-PUMP ASSEMBLY 9400613662 1014012333 220204700c


101401-2333 INJECTION-PUMP ASSEMBLY
Rating:
24
Buy INJECTION-PUMP ASSEMBLY 101401-2333 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 613 662 9400613662
ZEXEL 101401-2333 1014012333
HINO 220204700C 220204700c

Service parts 101401-2333 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101041-9241
3. GOVERNOR 105401-0820
4. SUPPLY PUMP 105220-5590
5. AUTOM. ADVANCE MECHANIS 105676-1052
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-5221
11. Nozzle and Holder 236002571A
12. Open Pre:MPa(Kqf/cm2) 21.6{220}
13. NOZZLE-HOLDER 105041-5171
14. NOZZLE 105015-6240
15. NOZZLE SET

Include in #1:

101401-2333 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 613 662 9400613662
ZEXEL 101401-2333 1014012333
HINO 220204700C 220204700c


Zexel num
Bosch num
Firm num
Name
101401-2333 
101401-2334 
9 400 613 662 
220204700C  HINO
INJECTION-PUMP ASSEMBLY
W04C-TI * K 14BC PE4A,5A, PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-0920
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   4.3 4.27 4.33
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.75 90.25
Difference between angles 2
Cal 1-4
deg.   180 179.75 180.25
Difference between angles 3
Cyl.1-2
deg.   270 269.75 270.25
Injection quantity adjustment
Adjusting point   A
Rack position   11.5
Pump speed r/min   1500 1500 1500
Average injection quantity mm3/st.   115 113 117
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the lever   *
Boost pressure kPa   45.3 45.3
Boost pressure mmHg   340 340
Injection quantity adjustment_02
Adjusting point   C
Rack position   8.4+-0.5
Pump speed r/min   325 325 325
Average injection quantity mm3/st.   10 8.5 11.5
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Boost compensator adjustment
Pump speed r/min   650 650 650
Rack position   R1(11.5)
Boost pressure kPa   4 2.7 5.3
Boost pressure mmHg   30 20 40
Boost compensator adjustment_02
Pump speed r/min   650 650 650
Rack position   R1-1.7
Boost pressure kPa   32 32 32
Boost pressure mmHg   240 240 240
Timer adjustment
Pump speed r/min   950--
Advance angle deg.   0 0 0
Load   1/4
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   900
Advance angle deg.   0.3
Load   1/4
Timer adjustment_03
Pump speed r/min   (1000)
Advance angle deg.   1.25 0.65 1.25
Load   4/4
Timer adjustment_04
Pump speed r/min   1200
Advance angle deg.   1.25 0.65 1.25
Load   3/4
Timer adjustment_05
Pump speed r/min   1500
Advance angle deg.   4.5 4.2 4.8
Load   4/4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-2333
N:Pump speed R:Rack position (mm) (1)Target notch: K (2)Tolerance for racks not indicated: +-0.05mm. (3)Set idle sub-spring (4)Main spring setting (5)Boost compensator stroke: BCL
----------
K=9 BCL=1.7+-0.1mm
----------

Speed control lever angle

Test data 101401-2333
F:Full speed I:Idle (1)Stopper bolt setting
----------

----------
a=11deg+-5deg b=26deg+-5deg

Stop lever angle

Test data 101401-2333
N:Pump normal S:Stop the pump. (1)Pump speed aa and rack position bb (to be sealed at delivery) (2)Normal
----------
aa=0r/min bb=1-0.5mm
----------
a=21deg+-5deg b=(55deg)

Timing setting

Test data 101401-2333
(1)Pump vertical direction (2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(70deg)




Have questions with 101401-2333?





Group cross 101401-2333 ZEXEL

Hino 

 
220204700A 
INJECTION-PUMP ASSEMBLY
W04C-TI
 
 
INJECTION-PUMP ASSEMBLY

Hino 

F 019 Z10 152 
220204700B 
INJECTION-PUMP ASSEMBLY
W04C-TI
101401-2333  

101401-2334 
9 400 613 662 
220204700C 
INJECTION-PUMP ASSEMBLY
W04C-TI
F 019 Z10 926 
220204700D 
INJECTION-PUMP ASSEMBLY
W04C-TI
Back to top