101401-2212 ZEXEL 9 400 619 542 BOSCH INJECTION-PUMP ASSEMBLY 9400619542 1014012212


101401-2212 INJECTION-PUMP ASSEMBLY
Rating:
77
Buy INJECTION-PUMP ASSEMBLY 101401-2212 zexel genuine, new aftermarket engine parts with delivery

Information injection-pump assembly

BOSCH 9 400 619 542 9400619542
ZEXEL 101401-2212 1014012212

Service parts 101401-2212 INJECTION-PUMP ASSEMBLY:

1. _
2. FUEL INJECTION PUMP 101040-9630
3. GOVERNOR 105921-4590
4. SUPPLY PUMP 105220-5300
5. AUTOM. ADVANCE MECHANIS 105676-0710
6. COUPLING PLATE
7. COUPLING PLATE
8. _
9. _
10. NOZZLE AND HOLDER ASSY 105110-5151
11. Nozzle and Holder 23600-2161A
12. Open Pre:MPa(Kqf/cm2) 19.6{200}
13. NOZZLE-HOLDER 105041-5160
14. NOZZLE 105015-8370
15. NOZZLE SET

Include in #1:

101401-2212 as INJECTION-PUMP ASSEMBLY

Cross reference number

BOSCH 9 400 619 542 9400619542
ZEXEL 101401-2212 1014012212


Zexel num
Bosch num
Firm num
Name
101401-2212 
101401-2213 
9 400 619 542 
   
INJECTION-PUMP ASSEMBLY
* K 14BC PE4A,5A, PE
101401-2212 
101401-2213 
9 400 619 542 
220006301B  HINO
INJECTION-PUMP ASSEMBLY
A * K 14BC PE4A,5A, PE

Calibration Data:

Adjustment conditions
Test oil
1404 Test oil
  ISO4113 or {SAEJ967d}
Test oil temperature degC   40 40 45
Nozzle and nozzle holder   105780-8140
Bosch type code   EF8511/9A
Nozzle   105780-0000
Bosch type code   DN12SD12T
Nozzle holder   105780-2080
Bosch type code   EF8511/9
Opening pressure MPa   17.2
Opening pressure kgf/cm2   175
Injection pipe
Outer diameter - inner diameter - length (mm)
mm   6-2-600
Overflow valve   134424-0920
Overflow valve opening pressure kPa   162 147 177
Overflow valve opening pressure kgf/cm2   1.65 1.5 1.8
Tester oil delivery pressure kPa   157 157 157
Tester oil delivery pressure kgf/cm2   1.6 1.6 1.6
Direction of rotation (viewed from drive side)
Right
  R
Injection timing adjustment
Direction of rotation (viewed from drive side)
Right
  R
Injection order   1-3-4-2
Pre-stroke mm   3.2 3.17 3.23
Beginning of injection position
Drive side
  NO.1
Difference between angles 1
Cal 1-3
deg.   90 89.75 90.25
Difference between angles 2
Cal 1-4
deg.   180 179.75 180.25
Difference between angles 3
Cyl.1-2
deg.   270 269.75 270.25
Injection quantity adjustment
Adjusting point   -
Rack position   12.2
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   78 76 80
Max. variation between cylinders %   0 -3 3
Basic   *
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_02
Adjusting point   H
Rack position   9.5+-0.5
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   8.5 7 10
Max. variation between cylinders %   0 -15 15
Fixing the rack   *
Standard for adjustment of the maximum variation between cylinders   *
Injection quantity adjustment_03
Adjusting point   A
Rack position   R1(12.2)
Pump speed r/min   900 900 900
Average injection quantity mm3/st.   78 77 79
Basic   *
Fixing the lever   *
Boost pressure kPa   26 26
Boost pressure mmHg   195 195
Injection quantity adjustment_04
Adjusting point   B
Rack position   R1-0.65
Pump speed r/min   1600 1600 1600
Average injection quantity mm3/st.   83.9 79.9 87.9
Fixing the lever   *
Boost pressure kPa   26 26
Boost pressure mmHg   195 195
Injection quantity adjustment_05
Adjusting point   C
Rack position   R1-0.4
Pump speed r/min   650 650 650
Average injection quantity mm3/st.   61.6 57.6 65.6
Fixing the lever   *
Boost pressure kPa   26 26
Boost pressure mmHg   195 195
Injection quantity adjustment_06
Adjusting point   D
Rack position   R2(12)
Pump speed r/min   300 300 300
Average injection quantity mm3/st.   49.7 47.7 51.7
Fixing the lever   *
Boost pressure kPa   0 0 0
Boost pressure mmHg   0 0 0
Injection quantity adjustment_07
Adjusting point   E
Rack position   R1-0.4
Pump speed r/min   1280 1280 1280
Average injection quantity mm3/st.   80.4 76.4 84.4
Fixing the lever   *
Boost pressure kPa   26 26
Boost pressure mmHg   195 195
Injection quantity adjustment_08
Adjusting point   I
Rack position   -
Pump speed r/min   100 100 100
Average injection quantity mm3/st.   107 107 117
Fixing the lever   *
Rack limit   *
Boost compensator adjustment
Pump speed r/min   300 300 300
Rack position   R2(12)
Boost pressure kPa   2 2 4.7
Boost pressure mmHg   15 15 35
Boost compensator adjustment_02
Pump speed r/min   300 300 300
Rack position   R1+1.3
Boost pressure kPa   12.7 12.7 12.7
Boost pressure mmHg   95 95 95
Timer adjustment
Pump speed r/min   1010--
Advance angle deg.   0 0 0
Load   1/4
Remarks
Start
 
Timer adjustment_02
Pump speed r/min   960
Advance angle deg.   0.3
Load   1/4
Timer adjustment_03
Pump speed r/min   1060
Advance angle deg.   1.5 1.2 1.8
Load   4/4
Timer adjustment_04
Pump speed r/min   1280
Advance angle deg.   1.8
Load   3/4
Timer adjustment_05
Pump speed r/min   1600
Advance angle deg.   4.5 4.2 4.8
Load   4/4
Remarks
Finish
 

Test data Ex:

Governor adjustment

Test data 101401-2212
N:Pump speed R:Rack position (mm) (1)Torque cam stamping: T1 (2)Tolerance for racks not indicated: +-0.05mm. (3)RACK LIMIT (4)Boost compensator stroke: BCL
----------
T1=F13 BCL=(1.5)+-0.1mm
----------

Speed control lever angle

Test data 101401-2212
F:Full speed I:Idle (1)Use the hole at R = aa (2)Stopper bolt set position 'H'
----------
aa=50mm
----------
a=21.5deg+-5deg b=43deg+-3deg

Stop lever angle

Test data 101401-2212
N:Pump normal S:Stop the pump.
----------

----------
a=13deg+-5deg b=40deg+-5deg

0000001501 ACTUATOR

Test data 101401-2212
(a) Screw (B) Nut (c) set bolt (d) control lever 1. Actuator adjustment procedure (1)Position the control lever (d) in the idling position. (2)Set the clearance between the control lever (d) and the set bolt (c) to approx. L1. (3)Loosen the nut (b) and fully tighten the screw (a). (4)Set the pump speed at N1and measure the rack position when negative pressure P1 is applied to the actuator. (5)Loosen screw (a) and fix the nut (b) when the pump speed is N2 and the rack position is R1. (6)Confirm that control lever (d) returns to the idling position at actuator negative pressure 0. (7)Repeat procedures (4) to (6) several times and confirm that the control lever (d) moves smoothly.
----------
L1=2mm R1=10.6~10.9mm P1=66.7kPa(500mmHg) N1=300r/min N2=300r/min
----------

Timing setting

Test data 101401-2212
(1)Pump vertical direction (2)Position of gear's standard threaded hole at No 1 cylinder's beginning of injection (3)- (4)-
----------

----------
a=(70deg)




Have questions with 101401-2212?





Group cross 101401-2212 ZEXEL

Hino 

 
220006300A 
INJECTION-PUMP ASSEMBLY
W04C-T
 
220006301A 
INJECTION-PUMP ASSEMBLY
W04C-TG
101401-2212  

101401-2213 
9 400 619 542 
 
INJECTION-PUMP ASSEMBLY

Hino 

101401-2212  

101401-2213 
9 400 619 542 
220006301B 
INJECTION-PUMP ASSEMBLY
9 400 613 654 
220006301B 
INJECTION-PUMP ASSEMBLY
W04C-TG
Back to top